My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12800 19TH AVE SE 2025-10-27
>
Address Records
>
19TH AVE SE
>
12800
>
12800 19TH AVE SE 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:13:31 AM
Creation date
4/4/2025 2:37:41 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12800
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ii <br />p (](]III❑III& <br />i <br />W l 0I 0 <br />CC MACHINE <br />SCANNER <br />MAIN CORRIDOR <br />(2) MONITORS <br />LIND <br />_RELOCATED <br />-KEYBOARD <br />-15' PEDESTAL <br />WATER FOUNTAIN <br />-PHONE <br />0001 <br />WRITE PAD <br />HALLWAYANAITING <br />AREA <br />110A <br />r <br />�m <br />WEST CORRIDOR <br />� <br />SECURITY L <br />© <br />TALL LOCKABLE CABIN <br />-LOCKERR j <br />CENTRALIZED <br />(3) 3) BO BODY CAMS <br />KIOSK r <br />CH© <br />CMACHINE <br />3 RADIOS% <br />SCANNER <br />SECURITY <br />W04 <br />_ <br />HALLWAY <br />1 00 <br />____ <br />9 <br />WRITE PAD <br />F1 FF&E PLAN - LEVEL 1 - NEW <br />P-11WD-2 - P-lA D-2 <br />n FINISH PLAN - LEVEL 1 - NEW <br />� 3116' = V-0" <br />2 <br />j <br />0 <br />FF&E SCHEDULE <br />FF&E N0. <br />DESCRIPTION <br />COORDINATION REQUIRED <br />Y <br />o <br />m <br />w <br />= <br />w <br />m <br />j <br />IL <br />O <br />w <br />> <br />OWNER FURNISHED/ CONTRACTOR INSTALLED <br />0001 <br />I COMPUTER WORKSTATION (2) MONITORS <br />0002 <br />ICOPIER <br />00D4 <br />WALL MOUNTED PHONE <br />OCOS <br />COFFEE MAKER <br />OCOB <br />RELOCATED FEC <br />0007 <br />RELOCATED MAILBOXES <br />OCOB <br />WALL MOUNTED KIOSK ON WALL BRACKET <br />OWNER FURNISHED I OWNER INSTALLED <br />0001 1 SHRED BIN <br />VENDOR FURNISHED/ VENDOR INSTALLED <br />W01 <br />!ADJ HEIGHT DESK <br />W02 <br />ITASKCHAIR <br />W03 <br />ITASKSTOOL <br />WD4 <br />I MOBILE PEDESTAL <br />MATERIAL FINISH LEGEND <br />NAME MANUFACTURER MATERIAL STYLE/SERIES COLOR(rEXTURE SIZE COMMENTS CONTACT <br />BASE <br />B-1 BURKE - MATCH EXISTING WALL BASE GINGER -503P 4"HIGH <br />CARPET <br />CPT-1 MANNINGTON CANOPY II HICKORY 24'z24" <br />CONCRETE STAIN <br />CONC-1 <br />STAINED CONCRETE <br />CONCRETE FLOOR W/TOPICAL <br />STAIN AND COLORANT ADDED AS <br />SPECIFIED <br />MATCH EXISTING ADJACENT <br />CONTINUE GRID PATTERN <br />CORNER GUARD <br />CG-1 <br />CONSTRUCTION SPECIALTIES <br />STAINLESS STEEL <br />CO.B <br />FULLHEIGHTOFWALL <br />APPLIED <br />CORNERGUARD <br />CG-2 <br />CONSTRUCTION SPECIALTIES <br />STAINLESS STEEL <br />FULL HEIGHT OF WALL <br />APPLIED <br />END CAP GUARD <br />PAINT <br />P-1 BENJAMIN MOORE DOVE WING OC-18 <br />P-2 SHERWIN WILLIAMS I INKY BLUE SW9149 <br />PLASTIC LAMINATE <br />PEA PIONITE LOVE LETTERS AW300-SD-TEXTURED SUEDE VERTICAL SURFACE AT DESK FRONTS <br />PL-2 TBD TBD TBD VERTICAL SURFACEAT CASEWORK <br />SOLID SURFACING <br />SSM-1 SILESTONE CALYPSO 943-POLISHED EASED EDGES, TYPICAL <br />WOOD <br />WD-1 <br />WOOD PANEL-3/4" <br />PLAIN SLICED EASTERN MAPLE- <br />MATCH EXISTING <br />MATCH EXISTING <br />18"H-SEE ELEVATION <br />WD-2 <br />WOOD BASE -3I4"X512" <br />1 EASTERN MAPLE -MATCH EXISTING <br />MATCH EXISTING <br />I 314"X5112" <br />10 11 <br />FF&E NOTES <br />1. SEE FURNITURE AND EQUIPMENT SCHEDULES FOR CONTRACTOR RESPONSIBILITIES. <br />2. SEE INTERIOR ELEVATIONS AND ACCESSORY MOUNTING HEIGHTS FOR ADDITIONAL INFORMATION PRIOR TO <br />t g b architects <br />INSTALL. <br />3. CONTRACTOR TO PROVIDE IN -WALL BLOCKING AS REQUIRED FOR EQUIPMENT. <br />4. CONTRACTOR TO VERIFY EQUIPMENT QUANTITIES SHOWN ON SCHEDULE WITH PLAN AND NOTIFY <br />ARCHITECTIOWNER OF ANY DISCREPANCIES PRIOR TO PLACING EQUIPMENT ORDER. <br />t 425.778.1530 21911 76th Ave W. Ste 210 <br />5. ALL FURNITURE TO BE OWNER PROVIDED AND OWNER INSTALLED UNLESS OTHERWISE NOTED. <br />f 425.774.7803 Edmonds WA 98026 <br />info@tgbarchilects.00m <br />www.tgbarchitects.com <br />FF&E SYMBOLS & ABBREVIATIONS <br />THESE ABBREVIATIONS ARE FOR USE IN FF&E TAGS ONLY. SEE SPEC SECTION 1.02 FOR MORE INFORMATION ON <br />FURNISH AND INSTALL RESPONSIBILITIES AND DEFINITIONS. <br />OC FURNISHED BY OWNER/INSTALLED BY CONTRACTOR <br />VC FURNISHEDBYVENDOR/ INSTALLED BY CONTRACTOR00 <br />FURNISHED I INSTALLED BY OWNER <br />�LKENT <br />�GKI <br />CC FURNISHED /INSTALLED BY CONTRACTOR <br />W FURNISHED /INSTALLED BY VENDOR <br />STATE OF WASNNGTQN <br />0001 FURNITURE & EQUIPMENT TAG <br />AO cR WA AUTO -DOOR OPENER, CARD READER, COMBINATION (PUSH PLATE) <br />17 DATA TERMINAL, VOICE TERMINAL, DATAIVOICE TERMINAL <br />DUPLEX ELECTRICAL RECEPTACLE <br />(T= <br />J�� EMERGENCY POWER <br />=9= =!=�� QUADPLEX ELECTRICAL RECEPTACLE <br />EMERGENCY POWER <br />FINISH NOTES <br />1, ALL EXPOSED WALL SURFACES SHALL BE FINISHED. <br />2. FINISHES TO BE INDICATED ON FINISH PLAN, ROOM FINISH SCHEDULE, AND INTERIOR <br />ELEVATIONS. REFER TO FINISH LEGEND FOR FINISH SELECTIONS. <br />3. FINISHES TO MEET FLAME SPREAD AND SMOKE DEVELOPED RATINGS PER CODE. <br />4, ALL MATERIALS TO BE INSTALLED ACCORDING TO MANUFACTURER'S <br />INSTRUCTIONIRECOMMENDATIONS AND INDUSTRY STANDARDS. <br />5. ALL FINISHES TO BE PATCHED AND REPAIRED SEAMLESSLY. ENSURE ALIGNMENT OF FINISHED <br />SIDE WHERE TWO DIFFERENT WALL TYPES INTERSECT. NOTIFY ARCHITECT BEFORE <br />PROCEEDING IF ALIGNMENT IS NOT POSSIBLE. <br />6. PATCH FINISHES AT CORRIDORS TO PROVIDE A SMOOTH TRANSITION BETWEEN NEW AND <br />EXISTING. <br />7. ALL WALL / CEILING MOUNTED FIRE EXTINGUISHER CABINETS, ELECTRICAL PANELS, HVAC <br />GRILLES, ACCESS PANELS, ETC, TO BE PAINTED TO MATCH ADJACENT WALL I CEILING COLOR. <br />8. PROVIDE COLOR MATCHED CAULK (MATCHING ADJACENT PLASTIC LAMINATE I SOLID SURFACE) <br />AT CASEWORK. CONTRACTOR TO SUBMIT SAMPLES FOR APPROVAL TO ARCHITECT. <br />9. IF ANY ITEMS ARE IDENTIFIED REQUIRING FINISH/COLOR SELECTION NOT ADDRESSED IN THESE <br />DRAWINGS, CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY & PROVIDE SAMPLES OF FINISH / <br />COLOR OPTIONS FOR SELECTION, CLEARLY IDENTIFYING ANY ABOVE BASE BID. <br />10. ALL FLOORING TRANSITIONS TO COMPLY WITH ADA REQUIREMENTS. <br />11. FLOORING SHALL EXTEND UNDERNEATH ALL OPEN COUNTERTOP WORK SURFACES. <br />12. ALL FLOORING TRANSITIONS BETWEEN ROOMS TO BE CENTERED UNDER DOOR IN CLOSED <br />POSITION U.O.N. TRANSITION STRIPS SHALL NOT BE VISIBLE FROM PUBLIC CORRIDOR SIDE. <br />13. CONTRACTOR TO BE RESPONSIBLE FOR TESTING SUBSTRATES FOR APPROPRIATE MOISTURE <br />LEVELS PRIOR TO INSTALLING MATERIALS. <br />14, ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARDS. <br />15. FINISH ALL VERTICAL & HORIZONTAL SURFACES OF SOFFIT WITH SPECIFIED FINISH. <br />FINISH SYMBOLS <br />FINISH ABBREVIATIONS USED ON THIS AND OTHER FINISH SHEETS INCLUDE THE FOLLOWING: <br />ACP ACOUSTICAL CEILING PANELS <br />B BASE <br />CC CUBICLE CURTAIN <br />CG CORNER GUARD <br />CONIC CONCRETE <br />CPT CARPET <br />FAB FABRIC <br />GL GLAZING OR GLASS <br />MTL METAL <br />PT PAINT <br />RS RESILIENT SHEET <br />RT RESILIENT TILE <br />SS STAINLESS STEEL <br />SSM SOLID SURFACING MATERIAL <br />T TILE <br />PLIPLAM PLASTIC LAMINATE <br />WC WALL COVERING <br />WD WOOD <br />WP WALL PROTECTION <br />® CPT-1 ° CORNER GUARD <br />- <br />END CAP & CORNER <br />EXISTING NOT IN SCOPE <br />CONCRETE <br />PROVIDENCE <br />PMG MILL CREEK <br />CENTRALIZED <br />CHECK -IN <br />12800 BOTHELL-EVERETT HWY <br />EVERETT, WA 98208 <br />PERMIT SET <br />FF&E & FINISH <br />PLANS <br />PROJECT INFORMATION <br />NORTH SHEET NO <br />A1.51 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.