Laserfiche WebLink
1 1 2 1 3 1 4 1 5 6 1 7 1 8 1 9 10 1 11 <br /> tgb architects <br /> x PROVIDENCE <br /> t 425.778.1530 21911 76th Ave W.Ste 210 <br /> f 425.774.7803 Edmonds WA 98026 <br /> PMG MILL CREEK CENTRALIZED info .tgbar hiiect.com <br /> www.tgbarchilects.com <br /> CHECK- IN REGISTERED <br /> iTELT <br /> L KENT GREY <br /> STATE OF WA$el►1GTQN <br /> 12800 BOTHELL-EVERETT HWY <br /> EVERETT, WA 98208 <br /> PERMIT SET <br /> PROVIDENCE <br /> PMG MILL CREEK <br /> CENTRALIZED <br /> EXITING DIAGRAM PROJECT NOTES PROJECT TEAM SHEET INDEX CHECK-IN <br /> 1.THESE DRAWINGS AND THE ACCOMPANYING SPECIFICATIONS ARE THE PROPERTY OF TGB ARCHITECTS OWNER: OWNER CONTACT: GENERAL <br /> AND ARE NOT TO BE COPIED OR REUSED FOR ANY OTHER PROJECT. PROVIDENCE HEALTH&SERVICES JAMES GRAFTON G0.00 COVER SHEET <br /> (425)218-0919 12800 BOTHELL-EVERETT HWY <br /> 2.DRAWINGS HAVE BEEN PREPARED FROM DATA AND DRAWINGS PROVIDED BY THE OWNER TO THE 1801 LIND AVE SW JAMES.GRAFTON@PROVIDENCE.ORG EVERETT,WA 98208 <br /> ARCHITECT.THE ARCHITECT HAS VERIFIED EXISTING CONDITIONS TO THE BEST OF THEIR ABILITY.THE RENTON,WA 98057 ARCHITECTURAL <br /> ARCHITECT ISSUES NO WARRANTY,NEITHER EXPRESSED NOR IMPLIED,FOR THE ACCURACY OR A6.01 INTERIOR ELEVATIONS <br /> COMPLETENESS OF THE INFORMATION INDICATED HEREIN. A6.02 INTERIOR ELEVATIONS <br /> ARCHITECT: PROJECT LEAD:JEANELLE OWENS A1.01 PLANS-DEMO&NEW <br /> 3.NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF EXISTING CONDITIONS THAT ARE CONTRARY TGB ARCHITECTS PRINCIPAL IN CHARGE:GINA DAIS A1.60 FF&E&FINISH PLANS <br /> TO THOSE REPRESENTED WITHIN THE DRAWINGS OR WHERE DIMENSIONS VARY GREATER THAN 2"THAN 425-778-1530 <br /> 2DM NDS,AVE W,SUITE 210 A5.50 PARTITION TYPES&DOOR&CEILING INFORMATION <br /> THOSE SHOWN IN DRAWINGS. EDMONDS,WA 98026 JOWENS@TGBARCHITECTS.COM A951 CASEWORK DETAILS <br /> 4.CONTRACTORTO COORDINATE REQUIREMENTS FOR INFECTION CONTROL DURING COURSE OF c <br /> CONSTRUCTION WITH OWNER PRIOR TO COMMENCEMENT OF WORK. GENERAL CONTRACTOR: GENERAL CONTRACTOR CONTACT: PERMIT JET <br /> 5.PROVIDE 24°SQUARE ACCESS PANELS OR OF SIZES REQUIRED WHERE PLUMBING AND HEATING VALVES, SUMMIT COMMERCIAL CONSTRUCTION PETER MEYER <br /> / WATER SWITCHES,OXYGEN PRESSURE SWITCHES,VENTILATION SPUTTER DAMPERS,ETC.ARE SHOWN ON 9700 HARBOUR PLACE PETER@SU MITCCLLC.COM <br /> L I PLUMBING AND MECHANICAL DRAWINGS.SUCH ACCESS PANELS TO BE INSTALLED IN THE FOLLOWING:A) SUITE 125 <br /> GWBBOARD CEILINGS)METAL STUD AND MASONRY PARTITIONS. MUKILTEO,WA 98275 <br /> e e 6 RWALL ASSEMBLIES ECESSED EQUIPMENTT BE MAINTAINED AT ALL RECESSED FIRE EXTINGUISHER CABINETS AND ALL <br /> LAI 7.PROVIDE FIRE EXTINGUISHER CABINETS OF THE TYPE SPECIFIED.REFER TO FLOOR PLAN(S)FOR <br /> LOCATIONS. <br /> 8,ALL SHAFT PARTITIONS EXTEND FROM FLOOR SLAB TO UNDERSIDE OF SLAB ABOVE.EXPOSED BEAMS COVER <br /> '� �+ <br /> WITHIN SHAFTS ARE TO BE FIREPROOFED WITH 2-HOUR GWBBOARD ENCLOSURE. CiOV E R SHEET <br /> 9.THE FIRE RATINGS OF ALL FIRE RATED PARTITIONS WILL BE STENCILED ABOVE CEILINGS,EACH SIDE OF <br /> PARTITIONS,BOTH SIDES OF CORRIDORS AND AS REQUIRED BY AUTHORITY HAVING JURISDICTION. <br /> 10.ALL GWB IS 5l8°TYPE'X'UNLESS NOTED OTHERWISE. ISSUANCE <br /> No. Description Date <br /> 11.THE DRAWINGS AND THE SPECIFICATIONS ARE COMPLEMENTARY.WHATEVER IS INDICATED IN ONE IS PERMIT SET 2/23124 <br /> �4H ED <br /> ASSUMED TO BE INDICATED IN THE OTHER.NOTIFY THE ARCHITECT IN CASE OF DISCOVERED <br /> EXISTING 1-HOUR PARTITION, LL DISCREPANCIES. <br /> � 12.ALL SUBSTRATES ARE TO BE SMOOTH PRIOR TO INSTALLATION OF FINISHES. <br /> g NOT AFFECTED BY NEW WORK <br /> Q °� 13.ALL WORK AND MATERIALS TO CONFORM TO FACILITY STANDARDS. <br /> _ - _ - _ - _ - _ - _ - _ ° _ ° _ - _ - _ - PROJECT DATA VICINITY MAP PROJECT INFORMATION <br /> w NORTH <br /> MAJOR APPLICABLE CODES: SCOPE OF WORK <br /> z 20181BC ®® REMODEL OF EXISTING RECEPTION AND SECURITY DESK AREA.NO STRUCTURAL WORK,NO MECHANICAL WORK. <br /> ICC A117.1-2009 APPROXIMATE AREA OF WORK:1300SF <br /> w i <br /> c�i I PROPERTY TYPE:MEDICAL OFFICE LEGAL DESCRIPTION <br /> �y�I'�� YEAR BUILT:1994(UBC 1991-TYPE 11,1 HOUR FULLY SPRINKLERED) Section 30 Township 28 Range 05 Quarter SE SEGE,FORTAX PURPOSES ONLY-LOT 1 PROVIDENCE MEDICAL CENTER <br /> 200 0426017895 BG REC AFN 200208155006 BEING PTN OF SEil4 SE114 LESS RD RhV TO CITY OF EVPER SWD REC AFN <br /> � NUMBER OF FLOORS:2 200204260193 EXC DOR EXEMPT PTN ON ACCT 28053000407200 DAF:21364 SQ FT OF BLDG(SURGI CENTER RM 210) <br /> i> TGW 16.4%OF LAND&PARKING ON E 646.17FT OF SD LOT 1(TAXABLE PTN) <br /> w MAIN OCCUPANT LOAD OF THE BUILDING:BUSINESS <br /> o m AREA OF WORK CONSTRUCTION TYPE:11-A FULLY SPRINKLERED TAX PARCEL NUMBER <br /> 28053000407201 <br /> Ff PROJECT AREA:APPROXIMATELY 1,300SF <br /> �vooy AUTHORITY HAVING JURISDICTION(AHJ) <br /> F <br /> CITY OF EVERETT <br /> 7 <br /> L4 <br /> �J APPLICABLE CODES <br /> AREA OF WORK DOES NOT BUILDINGCODE: WA STATE BUILDINGCODE(IBCWITHAMENDMENTS)-2018 <br /> IMPACT OCCUPANT LOAD LIFE EXISTING BUILDING CODE:WA STATE EXISTING-BUILDING CODE(IEBC WITH AMENDMENTS)-2018 <br /> e ENERGY CODE:WA STATE ENERGY CODE(IECC WITH AMENDMENTS)-2018 <br /> LIFE SAFETY CODE:NFPA 101-2012 <br /> SAFETY,OR EXISTING — FIRECODE:INTERNATIONAL FIRE CODE(IFC)-2018 PROJECT INFORMATION <br /> MECHANICAL CODE:INTERNATIONAL MECHANICAL CODE(IMC)-2018 PROJECT NUMBER: 23023 <br /> PLUMBING CODE:UNIFORM PLUMBING CODE(UPC)-2018 PROJECT LEAD: JLO <br /> ELECTRICAL CODE:NATIONAL ELECTRICAL CODE(NEC)-2020 DRAWN BY: JLO <br /> a ACCESSIBILITY CODE:ANSIA117.1-2009(BY REFERENCE FROM IBC AND WSBC) <br /> � NORTH <br /> DEFERRED SUBMITTALS <br /> LEVEL 1 EXITING DIAGRAM 1.ELECTRICAL SHEET NO <br /> 1 2 3 4 5 6 7 8 9 i 10 11 <br />