My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
625 RIVERSIDE RD SEPA 016 - 028 - FREIGHT HANDLING FACILITY Land Use Decision Documents 2025-04-21
>
Address Records
>
RIVERSIDE RD
>
625
>
SEPA 016 - 028 - FREIGHT HANDLING FACILITY
>
Land Use Decision Documents
>
625 RIVERSIDE RD SEPA 016 - 028 - FREIGHT HANDLING FACILITY Land Use Decision Documents 2025-04-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2025 2:34:35 PM
Creation date
4/4/2025 4:05:27 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
625
Tenant Name
SEPA 016 - 028 - FREIGHT HANDLING FACILITY
Address Document Type
Land Use Decision Documents
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
35. Fire Suppression (Sprinkler)System -An approved automatic suppression system shall be provided as required <br /> by City Ordinance No. 3021-07, EMC, Chapter 16.76. <br /> Plans for any such system shall be submitted to the Engineering & Public Services Department for examination <br /> and approval. Such plans shall include plans for the underground mains that will supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA 13, NFPA 13R, <br /> or NFPA 13D system depending upon several factors. Sprinkler installation shall not begin without an approved <br /> and stamped set of plans from the Engineering & Public Services Department. The Fire Department will also <br /> review the plans and shall field inspect the installation based only on approved plans that must be on site. <br /> Changes to plans must be approved by both the Engineering & Public Services and Fire Department. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. Underground <br /> piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for private fire mains. <br /> (Below-ground piping must be installed by Washington State Licensed Underground Sprinkler line certified "U" <br /> installers. For further information, contact the State Fire Marshal's Office at(360) 596-3900 or contact the Everett <br /> Fire Department at(425) 257-8124. All such tests shall be witnessed by a Fire Department Inspector. Call (425) <br /> 257-8124 or(425) 257-8120 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to issuance of <br /> any Certificates of Occupancy. 2015 IFC, WA State Amendment 903.3.5.3, Page 111. <br /> 36. The Snohomish County Emergency Radio System is employed by the City of Everett Fire Department emergency <br /> crews and operates at 800 MHz. Large metal-framed or metal and concrete buildings can weaken the signal so <br /> that communication and, therefore, firefighter safety is compromised. This structure must meet the requirements <br /> of EMC 16.03, Section 510, which specifically addresses required radio system performance standards in this <br /> structure. Your attention to this feature early in the planning stages will help avoid a costly, last-minute retroactive <br /> installation of radio signal amplification antennae and other equipment. <br /> 37. Floors and sub-floors at or above grade in buildings (other than parking garages) shall be marked with numbers, in <br /> ascending order, beginning with the number"1" (for the ground floor or first floor), then "2", "3", etc. Letters shall <br /> be used only to designate specific areas as detailed below. <br /> Floors below grade in buildings (other than parking garages) shall be marked with the letter"B" (when there is only <br /> one floor below grade). When there is more than one floor below grade, they shall be marked with the letter"B" <br /> followed by numbers, in descending order, beginning with the number"1" (for the floor immediately below the <br /> ground floor or first floor), then "2", "3", etc. Example—"B1", "B2", "B3", in descending order. <br /> Mezzanines shall be marked with the letter"M". When there is more than one mezzanine, they shall be marked <br /> with the letter"M"followed by numbers, in ascending order. Example—"M1", "M2", etc. <br /> Parking garages shall use the letter"P"to designate floors. When there is only one parking level at or above <br /> grade, it shall be marked with the letter"P". When there is more than one parking level at or above grade, they <br /> shall be marked with the letter"P" followed by numbers, in ascending order. Example—"P1" "P2", etc. When there <br /> is only one parking level below grade, it shall be marked"P01". When there is more than one parking level below <br /> grade, they shall be marked with the letter"P" followed by numbers, in descending order. Example—"P01", "P02", <br /> etc. <br /> 38. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with standard man <br /> door access. Locations shall be approved by the Fire Code Official (NFPA 13, 2013 edition, section 8.16.4.1.3). <br /> 39. The location of Fire Department connections (FDC) and post indicator valves(PIV) shall be determined by the Fire <br /> Code Official. If immediate outside man door access is available to the sprinkler valves (risers), a PIV will not be <br /> required. <br /> 40. Access road width with a hydrant-Where a fire hydrant is located on a fire apparatus access road, the minimum <br /> road width shall be 26 feet. 2015 IFC, Appendix D, D103.1. C� <br />
The URL can be used to link to this page
Your browser does not support the video tag.