Laserfiche WebLink
NOTES: — ` <br /> 1.Verify all conditions in the field. <br /> NEW POST PER STRUCTURAL BEYOND K I L B U R N <br /> NEW 2 X 2 PICKET PER STRUCTURAL ,�' " 4" {��\ ARCHITECTS LLC <br /> E; <br /> WALKWAY i z <br /> NEW PT.GLB.PER STRUCTURAL m _ <br /> EXISTING SHEATHING OR NEW PER SCOPE AND AS REQUIRED 11 SEALANT I <br /> EXTERIOR \\ 135 Lake Street South <br /> V.L�-A`-4- Suite 250 <br /> , i� EXISTING W.R.B TO REMAIN � Kirkland,WA 98033 <br /> NEW WATERPROOF DECK 2-PIECE METAL FLASHING <br /> EXISTING LAP SIDING,REMOVE AND RE-INSTALL 20R3 COATING,INSTALL PER NEW CONCRETE TOPPING SLAB PER STRUCTURAL Tel:206.682.5211 <br /> COURSES OF LAP SIDING TO PERFORM FLASHING WORK SPECIFICATIONS MANUFACTURERS AT TOP TREAD Fax:206.682.1403 <br /> NEW PRE-FINISHED CONTINUOUS 24 GA.METAL 24 GA BONDERIZED FLASHING WI <br /> SLOPE FLASHING Wl 112"HEMMED DRIP EDGE,PLANE SEALANT NEW BACKER ROD AND SEALANT —.kllburnarchitects.com <br /> SELF-ADHESIVE FLASHING OR LIQUID-FLASHING MEMBRANE TOPPING SLAB EDGE TO ACCEPT FLASHING NEW WATERPROOF DECK COATING, <br /> STARTER STRIP NEW 1 X CEDAR BLOCKING AS REQUIRED INSTALL PER MANUFACTURER'S 24 GA.2-PIECE METAL FLASHING,SET IN t,_ j <br /> NEW 24 GAUGE METAL DECK TO WALL FLASHING,SET IN SPECIFICATIONS BED OF SEALANT,SEE DETAIL ABOVE2 <br /> SEALANT SEALANT NEW CONCRETE NEW WATERPROOF DECK MEMBRANE-INSTALL PER SLABEXISTING DECK COATING TO REMAINMANUFACTURER'S SPECIFICATIONS SHEATHING PER EXISTING CONCRETE SLAB <br /> STRUCTURALNEW CONCRETE TOPPING SLAB TETOFD'�ASNINRGNTONSLOPE 'CF�j \ NEW LAP SIDING TO MATCH EXISTINGFRAMING PERQEz RN ARCxre ,=STRUCTURALNEW BLOCKING AS QUIRED NEWW.R.B,TYP. NOTENEW 5/8"TYPEX NEW DECK FRAMING PER 24 GAUGE FULLY SOLDERED METAL <br /> SHEATHING PER STRUCTURAL GYPSUM SOFFIT UCTURAL ISTING DECK FRAMING FLASHING <br /> \ \ <br /> NEW SHEATHING PER STRUCTURAL <br /> FRAMING PER STRUCTURAL -" $ 4" <br /> I ii <br /> NEW BEAM PER STRUCTURAL _ REPAIR FRAMING PER STRUCTURAL EXISTING WALKWAY FRAMING <br /> ti <br /> NEW 1 X 2 NAILER TO MATCH EXISTING <br /> EXISTING OR NEW VINYL'V CHANNEL TO MATCH AT BOTTOM OF STAIR <br /> NEW 518"TYPE'X EXISTING <br /> GYPSUM BOARD NEW VINYL VENTED SOFFIT TO MATCH EXISTING <br /> Flashing at Walkway to Wall Flashin at Walkway Edge Deck Coating Transition Flashing Flashing at Stair to Wall <br /> Scale:3"=T-0" Scale:3"=1'-0" �/ Scale:3"=1'-0" Scale:Ni <br /> Bluffs at Evergreen <br /> Walkway Repair <br /> (Bldg.H) <br /> 2 West Casino Road <br /> Everett,WA 98024 <br /> M \ <br /> Release Date <br /> \ CUT FLASHING PROPERLY WHERE TREAD END permit 11,4.2022 <br /> \ INTERSECTION WITH ADJACENT CURB,TYP. <br /> NEW WATERPROOF DECK MEMBRANE-INSTALL <br /> EXISTING OR NEW WALKWAY FRAMING,REPAIR PER MANUFACTURER'S SPECIFICATIONS <br /> 4•\\\ PER STRUCTURAL CONCRETE TOPPING SLAB PER NEW PRE-FINISHED CONTINUOUS 24 GA.METAL <br /> SCOPE FLASHING W/112'HEMMED DRIP EDGE,PLANE <br /> NEW I X 2 TRIM TO MATCH EXISTING NEW PLYWOOD 4" TOPPING SLAB EDGE TO ACCEPT FLASHING <br /> toSHEATHING TO MATCH <br /> T CONTINUOUS VENT STRIP EXISTING,TYP. EXTEND EXTEND CONCRETE TOPPING SLAB TO INFILL <br /> AT TOP TREAD ® EXISTING\PORNEW `EXISTING OR NEW WALKWAY FRAMING, <br /> t 4. CURB AS REQUIRED <br /> REPAIR PERSTRUCTURAL-7 NEW 1 X CEDAR <br /> 1 Q=KteUex nRCnnEcts,LW BLOCKING AS REQUIRED <br /> \ EXISTING OR NEW NEW FULLY SOLDERED 24 GAUGE METAL <br /> 2'CONTINUOUS VENT <br /> VYF \ FRAMING PER FLASHING COLLAR,SEE ISOMETRIC <br /> Lyj NEW LAP SIDING TO EXISTING OR NEW "TYPE STRUCTURAL <br /> EXISTING OR NEW s/s'TYPE'X GYPSUM SOFFIT MATCH EXISTING 'X'GYPSUM SOFFIT EXISTING OR NEW 24 GAUGE METAL VENT COVER <br /> ` NEW SLEEVE ATTACH TO LOUVERED VENT <br /> \\ NEW VINYL VENTED SOFFIT TO MATCH EXISTING I I <br /> "�`�� COVER WITH SEALANT <br /> ATTREADS \\ _ EXISTING OR NEW VINYL'VCHANNEL TO DUCTSEAL TO VEN SLEI><1 EXISTING EXHAUST TE\IE TERMINATISTING OR <br /> KNEW VINYL LOUVERED VENT <br /> MATCH EXISTING <br /> 4" \ NEW VINYL VENTED SOFFIT TO MATCH EXISTING 2"CONTINUOUS VENTFT FLASHING COLLAR,BEYOND <br /> STRIP SET IN BED OF SEALANT <br /> NOTE: EXISTING LAP SIDING TO REMAIN,TYP. NEW 1 X2 NAILER TO MATCH EXISTING <br /> 24 GAUGE FULLY SOLDERED METAL <br /> SEALANT JOINT <br /> FLASHING NEW SELF-ADHESIVE EXISTING OR NEW VINYL'J'CHANNEL TO MATCH NEW SILL FLASHING AS REQUIRED <br /> EXISTING WEATHER-RESISTIVE TO REMAIN,TYP. FLASHING MEMBRANE EXISTING <br /> \ OR LIQUID-FLASHING NEW%'TYPE'X'GYPSUM BOARD EXISTING WEATHER-RESISTIVE BARRIER <br /> 6 a^ \ <br /> EXISTING OR NEW 5I8'TYPE'X GYPSUM SHEATHING NEW BEAM PER STRUCTURAL EXISTING OR NEW LAP SIDING TO MATCH <br /> LL PER SCOPE AND AS REQUIRED EXISTING PER SCOPE,TYP. <br /> NEW 24 GA.METAL SEALANT EXISTING SHEATHING,REPAIR AS NECESSARY <br /> FLASHING W/1/2" <br /> PER SCOPE <br /> HEMMED DRIP EDGE <br /> AT BOTTOM OF STAIR ' <br /> NEW 1 X FIBER-CEMENT TRIM Details <br /> J Flashing at Stair to Curb Soffit Termination at Wall Siding Termination at Overhang Vent Penetratin Flashing <br /> Scale:N.T.S V Scale:3"=1'-0" Scale:3"=1'-0" o Scale:3"=1'-0" <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT A-2.1 <br /> Q mn rcLsuax nacxllccre,uc <br />