My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2 W CASINO RD 2022 BLDG H Plans 2025-04-07
>
Address Records
>
W CASINO RD
>
2
>
BLDG H
>
Plans
>
2 W CASINO RD 2022 BLDG H Plans 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 7:43:04 AM
Creation date
4/7/2025 7:42:40 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2
Tenant Name
BLDG H
Permit
B2211-071
Year
2022
Notes
BLDG H - PROPOSED REPAIR OF DAMAGED STAIRS, WALKWAY, SOFFIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> 1.Verify all conditions in the field. <br /> '� KILBURN <br /> J FOSr NOTE: <br /> FULLY SOLDERED ALL JOINT <br /> 1/2"HEMMED <br /> EDGE "fir ARCHITECTS LLC <br /> B <br /> 4" O <br /> 0. <br /> Street South <br /> Su[250 <br /> BOTTOM FLANGE OF VENT NOTE:WHERE MULTIPLE VEMS \` NEW PT.GLB PER STRUCTURAL Kirkland,WA 98033 <br /> & COLLAR SHALLCOVER TOP OCCUR,GANG UNDER ONE �^ �YF O2\ / 7e1:206.682.5211 <br /> OFSIDING.V.I.F. HOOD.VERIFY WITH ARCHITECT. 2-PIECE SADDLE FLASHING 'A <br /> Fax 206.682.1403 <br /> STAIR PER <br /> EXTEND 3" ' STRUCTURAL7 <br /> •s_;s .� r <br /> S NEW 5I8"TYPE'X'GYPSUM BOARD <br /> SLEEVE 4"MIN. <br /> / 7 —.kllburnarchltects.com <br /> OVERX� <br /> A P EXISTING Q "'x•'�" '� "�' <br /> DUCT I •, ,...:,.�;�' <br /> EXISTING OR NEW 518"TYPE <br /> 'X GYPSUM SHEATHING tlfiE <br /> SLOPE �NEW BEAM PER STRUCTURALBOTTOM AND ° EXISTING OR NEW VENTED VINYL <br /> TOP FLANGES ° 24GA.METAL DECK EDGE FLASHING SOFFIT,TYP. <br /> WI 1PG"HEMMED DRIP EDGEL____ EXISTING OR NEW VINYLVCHANNEL TO MATCH lyASxINGiON <br /> VENT FLASHING EXISTING NEW PLYWOOD SHEATHING <br /> COLLAR ISOMETRIC ° REMOVABLE VENT EXISTINGOR NEW VINYLVCHANNELTOMATCH NEWW.Re,TYP. <br /> WALKWAY FRAMING PLAN <br /> 5" COVER.ATTACH WITH PER STRUCTURAL EXISTING NEW LAP SIDING <br /> GASKETED FASTENERS EXISTING OR NEW VENTED VINYL PROVIDE 118"SEALANT GAP AT SIDING/TRIM JOINT PER <br /> VENT COVER ISOMETRIC O NEW 2-PIECE 24 GAMETAL SADDLE OO SOFFIT,TYP. MANUFACTURER'S SPECIFICATIONS,APPLY SEALANT <br /> ISOMETRICS NOT TO SCALE <br /> FLASHING WRAP-HEM ALL EXPOSED EXISTING OR NEW 518"TYPE'X GYPSUM NEW 1 X FIBER-CEMENT TRIM,ALIGN WITH POST ABOVE TO <br /> EXISTING POST EDGES,.SET IN SEALANT,TYP. <br /> SHEATHING MATCH EXISTING ELEVATION <br /> NEW 1 X 2 TRIM TO MATCH EXISTING <br /> O O O EXISTING OR NEW 518"TYPE EXISTING OR NEW VINYL W CHANNEL TO MATCH <br /> X GYPSUM SHEATHING EXISTING <br /> PLAN VIEW <br /> 24GA.METAL EDGE FLASHING W1 <br /> 112"HEMMED DRIP EDGE <br /> Vent Collar and Cover-Isometirc addle Flashing at Base of Post Deck Coating Transition Flashing Siding Transition <br /> -Ia N.T.S Smale:3"=r-0" J Scale:3"=V-0" `F Scale:3"=1'-0" <br /> Bluffs at Evergreen <br /> Walkway Repair <br /> (Bldg.H) <br /> 2 West Casino Road <br /> Everett,WA 98024 <br /> NEW PT.6 X 6 POST PER STRUCTURAL BEYOND Release Date <br /> permit 11.4.2022 <br /> Ilk-,. NEW PT.2 X 8 CAP W/SLOPE SECTION <br /> NEW POST PER STRUCTURAL <br /> SECTION <br /> PLANE PPING SLAB EDGE TO SEALANT <br /> NEW PT.POST PER STRUCTURAL,-PAINT <br /> TO <br /> ACCEPT FLASHING <br /> NEW SELF-ADHESIVE FLASHING MEMBRANE <br /> 3 NEW WATERPROOF DECK <br /> NEW PT.GLB PER STRUCTURAL COATING-INSTALL PER NEW CONCRETE TOPPING SLAB PER STRUCTURAL <br /> o MANUFACTURER'S <br /> SPECIFICATIONS <br /> V.I.F NEW 2-PIECE 24 GA METAL SADDLE FLASHING WI <br /> N <br /> 112'HEMMED DRIP EDGE,SET IN BED OF SEALANT <br /> NEW 24 GA.2-PIECE METAL <br /> NEW t XCEDAR BLOCKING AS REQUIRED SADDLE FLASHING,•SET IN <br /> SEALANT,SEE DETAIL#21A-2.2 NEW WATERPROOF DECK COATING <br /> NEW 2X2 PICKET PER STRUCTURAL NEW CONCRETE TOPPING SLAB INSTALL PER MANUFACTURER'S <br /> Ix 7 <br /> 4" TO MATCH EXISITNG SPECIFICATIONS <br /> NEW IX FIBER•CEMENT TRIM +,, •4; ' a*`" <br /> FRAMING PER <br /> STRUCTURAL NEWW.R.B,TYP. <br /> EXTERIOR � <br /> WALKWAY © NEW SHEATHING PER STRUCTURAL SHEATHIN PE TRUCTURAL <br /> WALKWAY <br /> FRAMING PER <br /> STRUCTURAL <br /> Details <br /> Railing Top-Section Lashing Ill Post at Walkway Edge Flashing wl Post at Walkway Edge <br /> Scale:3"=1'-D" v Scale:3"=1'-D" ��J Scale:3"=1'-0" CITY OFEVERETT <br /> REVIEWED FOR PERMIT <br /> A-2.2 <br /> ©mu uleu"Naacrire-,s,_c <br />
The URL can be used to link to this page
Your browser does not support the video tag.