My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3520 19TH ST 2022 Plans 2025-04-07
>
Address Records
>
19TH ST
>
3520
>
Plans
>
3520 19TH ST 2022 Plans 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 11:25:54 AM
Creation date
4/7/2025 11:24:22 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH ST
Street Number
3520
Permit
B2206-052
Year
2022
Notes
AFH - CONVERT SFR TO AFH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS: <br /> DATE: X%-m4O( <br /> /Ex1STING CONC. PLUMBING NOTES: <br /> PORCH ACCORDING TO THE INTERNATIONAL RESIDENTIAL CODE, <br /> EVERY TRAP OR TRAPPED FIXTURE REQUIRES A VENT. <br /> THE VENT SYSTEM TYPICALLY CONSISTS OF A MAIN VENT <br /> (N)3648 SL (E)7068 SL THAT EXTENDS ABOVE THE ROOF FAR ENOUGH TO PREVENT <br /> (VENT TO EXTERIOR) 05.1 DOMESTIC SYSTEMS. OBSTRUCTION FROM SNOW. OTHER VENTS IN THE HOUSE <br /> WHERE DOMESTIC RANGE HOODS AND DOMESTIC LINK TO THIS MAIN VENT. VENTS ARE REQUIRED TO BE <br /> APPLIANCES EQUIPPED WITH DOWNDRAFT AT LEAST HALF THE DIAMETER OF THE DRAINPIPE THAT <br /> EXHAUST ARE PROVIDED, SUCH HOODS AND THEY SERVE, SO A 3-IN. DRAINPIPE SERVING A <br /> APPLIANCES SHALL DISCHARGE TO THE SINGLE-FAMILY HOME NEEDS A MAIN VENT THAT IS AT <br /> OUTDOORS THROUGH SHEET METAL DUCTS LEAST 1-1/2 IN. DIA. <br /> CONSTRUCTED OF GALVANIZED STEEL, B E D R O O M#3 0 <br /> STAINLESS STEEL, ALUMINUM OR COPPER. 3 ALLOW TO CONNECT THE KITCHEN VENT TO THE MAIN <br /> SUCH DUCTS SHALL HAVE SMOOTH INNER WAI@.$n A°' VENT IN THE ATTIC AS LONG AS THE MAIN VENT IS THE <br /> SHALL BE AIR TIGHT, SHALL BE HH PROPER SIZE AND EXTENDS THROUGH THE ROOF. A VENT <br /> EQUIPPED WITH A BACK DRAFT DAMPER AND 3 c KITCHEN/DINING PIPE IS REQUIRED TO BE 3-IN. VENT PIPES DIA. rn <br /> SHALL BE INDEPENDENT OF ALL OTHER INSTALLED IN PROPOSED 1-BEDROOM.. _rn <br /> EXHAUST SYSTEMS. <br /> Z DRYER EXHAUST DUCT FOR CLOTHES DRYER SHALL Iv <br /> L7`" LIVING ROOM 0 v <br /> MECH. VENTILATING SYSTEMS IN w TERMINATE ON THE OUTSIDE OF THE BUILDING AND <br /> BATHROOMS, LAUNDRY ROOM SHOULD SHALL BE EQUIPPED WITH A BACK DRAFT DAMPER 5 L11 m <br /> LOCATED WHERE THE DUCT TERMINATES. DRYER EXHAUST 0) 1 CO <br /> EXHAUST DIRECTLY TO THE OUTSIDE. THE POINT OF DISCHARGE OF EXHAUST AIR DUCT MAY TERMINATE AT EXTERIOR WALL LOUVER WITH N U) Lu Q <br /> SHALL BE AT LEAST 3 FEET FROM ANY OO [0] AN OPENING SPACE NOT LESS THAT }" INCH IN ANY o Z Q <br /> OPENING INTO THE BUILDING. S C § DIRECTION. H1- Y Z v <br /> n Lu <br /> O �Ov <br /> 408.6 SHOWER COMPARTMENTS. SHOWER { 225.0 WATER HEATER (CONSUMER ELECTRIC STORAGE) - A C N Z o <br /> COMPARTMENTS, REGARDLESS OF SHAPE, �' CONSUMER PRODUCT THAT USES ELECTRICITY AS THE ENERGY } o F j m <br /> SHALL HAVE A MINIMUM FINISHED INTERIOR a SOURCE TO HEAT DOMESTIC POTABLE WATER, HAS A CL u W W O Ln <br /> NAMEPLATE INPUT RATING OF TWELVE KILOWATTS OR LESS, O _J N U <br /> OF NINE HUNDRED (900) SQUARE INCHES OO THERMOSTAT U <br /> (0.58 M2) AND SHALL ALSO BE CAPABLE OF \ w ° CONTROLS R403.1 CONTAINS NOMINALLY FORTY GALLONS BUT NO MORE <br /> ENCOMPASSING A THIRTY (30) INCH (762 ° THAN ONE HUNDRED TWENTY GALLONS OF RATED HOT WATER <br /> MM) CIRCLE. THE MINIMUM REQUIRED AREA STORAGE VOLUME, AND SUPPLIES A MAXIMUM HOT WATER <br /> AND DIMENSIONS SHALL BE MEASURED AT A DELIVERY TEMPERATURE LESS THAN ONE HUNDRED EIGHTY <br /> HEIGHT EQUAL TO THE TOP OF THE ,Cy kj DEGREES FAHRENHEIT. <br /> THRESHOLD AND AT A POINT TANGENT TO ITS VENT o VENT <br /> L CENTERLINE. THE AREA AND DIMENSIONS ALIN DRY ROOM 407.2 WATER CONSUMPTION. THE MAXIMUM WATER FLOW RATE OF <br /> SHALL BE MAINTAINED TO A POINT OF NOT FAUCETS SHALL COMPLY WITH SECTION 407.2.1 THROUGH SECTION <br /> LESS THAN SEVENTY (70) INCHES (1,778 HALL w w 407.2.2 <br /> MM) ABOVE THE SHOWER DRAIN OUTLET WITH ® y m 407.2.1 MAXIMUM FLOW RATE. THE MAXIMUM FLOW RATE FOR <br /> NO PROTRUSIONS OTHER THAN THE FIXTURE BEDROOM#2 PUBLIC LAVATORY FAUCETS SHALL NOT EXCEED 0.5 GPM AT 60 <br /> VALVE OR VALVES, SHOWER HEAD, SOAP u u w PSI (1.9 L/M <br /> DISHES, SHELVES, AND SAFETY GRAB BARS m AT 414 KPA). I� <br /> -^ <br /> OR RAILS - (TYP. ALL SHOWERS) v' 407.2.1.1 RESIDENTIAL LAVATORY FAUCETS. THE MAXIMUM FLOW v1 <br /> CLOSET CLOSET RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT EXCEED 1.2 <br /> OO ALL BATHROOMS - TOILET GALLONS (4.54 L) PER MINUTE AT 60 PSI. THE MINIMUM FLOW r <br /> BRANCH WATER LINE y S C ROOMS MECHANICAL EXHAUS w RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS W <br /> WATER LINE CAPACITY OF 50 CFM THAN 0.8 GALLONS (3.03 L) PER MINUTE AT 20 PSI. <br /> 17 <br /> SINK WASTE LINE, BATH va a k �• INTERMITTENT OR 20 CFM 407.2.1.2 LAVATORY FAUCETS IN COMMON AND PUBLIC USE <br /> WASTE LINE HOUSE SEWER. (NO U CONTINUOUS TYP.R303.3 AREAS. THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS, <br /> CHANGES) cD { ' ATHROOMS. INSTALLED IN COMMON AND PUBLIC USE AREAS (OUTSIDE OF <br /> DWELLINGS OR SLEEPING UNITS) IN RESIDENTIAL BUILDINGS, <br /> J N p_pK p_p SHALL NOT EXCEED 0.5 GALLONS (1.89L) PER MINUTE AT 60 <br /> IF THE BATHROOM WAS CHANGED o m /� S O N PSI. <br /> a BEDROOM#5 `�� <br /> OUT, THEN RECONNECT HOT AND m S S• BATH E 407.2.2 METERING FAUCETS. METERED FAUCETS SHALL DELIVER <br /> COLD WATER LINES TO NEW z 1 A A MAXIMUM OF 0.25 GALLONS (1.0 L) PER METERING CYCLE IN <br /> SINKS, TOILETS, AND SHOWERS r o (DO , <br /> ; \G,pN HALL ACCORDANCE WITH ASME A112.18.1/CSA B125.1. } <br /> AT THEIR NEW LOCATIONS. <br /> FOLLOW ALL PLUMBING 2018 / ���""" ® 402.5 SETTING. FIXTURES SHALL BE SET LEVEL AND IN W <br /> i <br /> CODES WHEN REWORK IS BEING / - ° ° PROPER ALIGNMENT WITH REFERENCE TO ADJACENT WALLS. NO 0 <br /> DONE. _ _ WATER CLOSET OR BIDET SHALL BE SET CLOSER THAN FIFTEEN J <br /> NEW CLOSET ro.Fr so.r-r d (15) INCHES (381 MM) FROM ITS CENTER TO ANY SIDE WALL Lu <br /> i OR OBSTRUCTION NOR CLOSER THAN THIRTY (30) INCHES (762 N <br /> / OO MM) CENTER TO CENTER TO ANY SIMILAR FIXTURE. THE CLEAR <br /> FOYER <br /> w \, SPACE IN FRONT OF ANY WATER CLOSET OR BIDET SHALL BE E <br /> O i \• q NOT LESS THAN TWENTY-FOUR (24) INCHES (610 MM). NO <br /> u i \ w / } <br /> BEDROOM#6 B E D R O O M#1 URINAL SHALL BE SET CLOSER THAN TWELVE (12) INCHES (305 D� <br /> j W MM) FROM ITS CENTER TO ANY SIDE WALL OR PARTITION NOR <br /> OO U <br /> S i R XBt CLOSER THAN TWENTY-FOUR (24) INCHES (610 MM) CENTER TO N <br /> n CENTER. <br /> AIR <br /> y CLOTHES DRYER EXHAUST DUCTS SHALL BE TERMINATED IN � o <br /> CIRCULATI CONCRETE ACCORDANCE WITH SECTION 1502.3. H w <br /> DRYER VENT WITH FLEXIBLE DUCT RUN IT AREA FOR LANDING F3 R303.5.2 EXHAUST OPENINGS. EXHAUST AIR SHALL NOT BE C9 W CO <br /> THROUGH THE WALL NEXT TO THE DRYER, pC W <br /> THREE FEET FROM ANY OPENING, TABLE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE x Q <br /> 1507,4 A T FROM <br /> CFM OF 4" DIAMETER OUTSIDE THE BUILDING. TERMINAL ELEMENTS SHALL HAVE AT <br /> LEAST THE EQUIVALENT NET FREE AREA OF THE DUCT WORK. <br /> EGRESS WINDOW (E)7098 SL L <br /> 1. 1}" DIA. VENT TO ROOF 8"x8" R303.5.2.1 EXHAUST DUCTS. EXHAUST DUCTS SHALL BE EQUIPPED � � <br /> FOR SINK. (N)7048 SL PERMANE WITH BACK-DRAFT DAMPERS. ALL EXHAUST DUCTS IN Q W <br /> 2. 1 " VENT TO ROOF FOR BATH SINK AND OPENING R UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF U <br /> )1 COMB. AlFROM R-4, to N W <br /> TOILET. R303.10 REQUIRED HEATING. WHEN THE OUTSIDE R303.7 INTERIOR STAIRWAY ILLUMINATION. INTERIOR STAIRWAYS O <br /> 3. 1 DIA. SINK WASTE LINE, BATH WASTE WINTER DESIGN TEMPERATURE IN TABLE O m W <br /> �� k SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO <br /> LINE R301.2(1) IS BELOW 0°F (16°C), ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION a <br /> 4. 3" DIA. WASTE PIPE TOILET CONNECT TO EVERY DWELLING UNIT SHALL BE SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE <br /> EXIST HOUSE SEWER. PROVIDED WITH HEATING FACILITIES LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND <br /> 5. LAUNDRY PIPE 2" DIA. CAPABLE OF MAINTAINING A MINIMUM01 <br /> ROOM TEMPERATURE OF 68°F (20°C) AT LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE (11 LUX) a _ <br /> A POINT 3 FEET (914 MM) ABOVE THE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE <br /> 6. 408.4 WASTE OUTLET. SHOWERS SHALL HAVE A FLOOR AND 2 FEET (610 MM) FROM SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE <br /> WASTE OUTLET AND FIXTURE TAILPIECE NOT LESS THAN EXTERIOR WALLS IN ALL HABITABLE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. <br /> TWO (2) INCHES (50 MM) IN DIAMETER. ROOMS AT DESIGN TEMPERATURE. THE <br /> FIXTURE TAILPIECES SHALL BE CONSTRUCTED FROM THE INSTALLATION OF ONE OR MORE PORTABLE <br /> MATERIALS SPECIFIED IN SECTION 701.1 FOR DRAINAGE HEATERS SHALL NOT BE USED TO ACHIEVE CONTENr. <br /> PIPING. STRAINERS SERVING SHOWER DRAINS SHALL COMPLIANCE WITH THIS SECTION. <br /> HAVE A WATERWAY AT LEAST EQUIVALENT TO THE AREA <br /> OF THE TAILPIECE. <br /> PLUMBING <br /> NEW SIDEWALK FLOOR <br /> TO DRIVEWAY PLAN <br /> PLUMBING P L A N DRAWN BY: DL <br /> DATE: 0a/2112022 <br /> ELDERLY REMODELING PROJECT <br /> SCALE: 1I411'-0• <br /> DORCAS MWANGI <br /> PROJECT NUMBER: A-0188 <br /> 3520 19th. ST. EVERETT,WA, 98201 M fl 4 M <br /> SCALE:3"= 1'-0" W W u W SHEET NO: <br /> A4.0 <br /> ALL VARIATIONS FROM CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWING SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION PRIOR OR PROCEEDING TO THE WORK OR OTHERWISE,THE CONTRACTOR SHALL SE SOLELY RESPONSIBLE <br /> FOR COSTS OF ANY NECESSARY REMEDIAL WORK.REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT. <br /> THE IDEAS AND DESIGNS INCORPORATED HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF NORTHWEST VINTAGE HOMES AND IS NOT TO BE USED IN WHOLE OR IN PART,FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM NORTHWEST VINTAGE HOMES <br />
The URL can be used to link to this page
Your browser does not support the video tag.