Laserfiche WebLink
Permit#: K2310-015 <br /> FUSIBLE LINK TEMPERATURE SELECTION CONNECTION TO SUPPLY AIR, SHUTS DOWN UPON MU Site Address: 6600 Evergreen Way <br /> SHALL BE PER THE ANSUL INSTALLATION SYSTEM DISCHARGE (CONNECTION BY OTHERS) Applicant: Pye-Barker Fire and Safety LLC <br /> MANUAL RECOMMENDATIONS <br /> CONNECTION TO ALL ELECTRIC UNDER THE Application Date: 11/28/2023 <br /> HOOD, SHUTS DOWN UPON SYSTEM DISCHARGE ES Description: New Ansul UL300 Fire Suppression <br /> (CONNECTION BY OTHERS) System <br /> CONNECTION TO F.A.C.P., ACTIVATES UPON FA 16'-1' <br /> Review Date: 12/04/2023 <br /> SYSTEM DISCHARGE (CONNECTION BY OTHERS) <br /> A <br /> 16" DIA EVERETT <br /> EVERETT <br /> INLINE BURST DISK DUCT „„,„.o, �► <br /> __ Everett Fire Dept.Permit Review <br /> 2W I Status:Approved <br /> I I Reviewed By:KBrown <br /> 12/04/2023 1:59:26 <br /> REGULATED RELEASE —— — — PM <br /> (2) 3 GALLON TANKS 11N 60 she 360 360 360 1N <br /> DOUBLE TANK CARTRIDGE <br /> 2 1 I <br /> 1F 1F LN <br /> 1N IN 230 <br /> P'N <br /> 2120 40"-48" 15'-40' <br /> 27"-47" <br /> 40"-50" 10"-20" <br /> � � m m oo -bee <br /> m <br /> az"-as" �ID <br /> 000 <br /> 000 <br /> 000 <br /> REMOTE PULL STATION 1.5" MECHANICAL GAS SHUT 18"x18" 36" 24" 24" 1 14" <br /> SHALL BE LOCATED IN AN UNOBSTRUCTED LOCATION BETWEEN OFF VALVE INSTALLED STOCK POT GRIDDLE RANGE CHAR I FRYER <br /> 42" AND 48" ABOVE THE FINISHED FLOOR (AFF) IN THE BEFORE FIRST APPLIANCE RANGE BROILER <br /> PATH OF EGRESS, OR AT A LOCATION ACCEPTABLE TO THE BY OTHERS 60" L <br /> AUTHORITY HAVING JURISDICTION. SALAMANDER [—BAFFLE PER NFPA 96 <br /> CLASS K FIRE EXTINGUISHER <br /> SHALL BE INSTALLED NO MORE THAN 60" ABOVE THE i___ 12 ———___ I <br /> FINISHED FLOOR WITHIN 30' FROM THE HAZARD <br /> ANSUL R102 - 6 GALLON MANIFOLDED SYSTEM <br /> NOZZLE SUMMARY TABLE TANKS 1 & 2 USE 15 of 22 FLOW POINTS <br /> HAZARD QTY NOZZLE PTS TOTAL SYSTEM PIPING LIMITATIONS <br /> TANKS 1 & 2 - (2) 3 GALLONS (22 FLOW POINTS MAX) 6CiALLON(1144NIFOLDED) PYE* <br /> STOCK POT RANGE 1 245 2 2 1DUCT PLENUM APPLIANCE BARKER <br /> GRIDDLE 1 2120 2 2 REQUIREMENTS SUPPLY BRANCH BRANCH BRANCH paell FIRE 6 SAFETY-EST 1946 <br /> SALAMANDER 2 1N 1 2 PIPE SIZE 3/8" 1 3/8" 3/8" 3/8" LUNA MEXICAN RESTAURANT <br /> RANGE 2 1F 1 2 <br /> CHARBROILER 1 1N 1 1 MAXIMUM LENGTH 32FT 8FT 4FT 12FT 6600 EVERGREEN WAY <br /> FRYER 1 230 2 2 MAXI MUM RISE 6FT 4FT 2Ff 2Ff EVERETT, WA 98203 <br /> DUCT 1 2W 2 2 MAX 90 ELBOWS 8 4 4 6 <br /> PLENUM 2 1N 1 2 MAX TEES 2 2 2 4 735 E. FAIRHAVEN AVE. slzE owe No DWG REV <br /> TOTAL 15 MAX FLOW POINTS 22 4 2 4 BURLINGTON, WA 98233 KITCHEN FIRE SYSTEM 1 <br /> PRE-ENGINEERED SHOP DRAWING ONLY - NOT TO SCALE (360) 755-5444 SCALE N/A 11/17/2023 SHEET 1 OF 11 <br />