Laserfiche WebLink
NOTES EVERETT SHOPS <br /> 5"MAX 1. CATCH BASIN INSERTS SHALL BE REMOVED AT THE <br /> END OF THE PROJECT. REDEVELOPMENT <br /> DRAINAGE GRATE TRIM <br /> 2. CATCH BASIN INSERTS ARE ONLY TO BE INSTALLED IN <br /> DRAINAGE DEVICES PER THE MANUFACTURES'S <br /> L City of Everett Permit Review <br /> RECOMMENDATIONS.CATCH BASIN INLET INSERTS EVERETT Status:Approved <br /> GRATE FRAME OVERFLOW BYPASS SHALL BE INSTALLED IN CURB INLETS. ^^•^^°•°^ <br /> 08/05/2023 11:15:25 AM <br /> SEDIMENT BELOW INLET GRATE 3. CATCH BASIN INSERTS SHALL BE INSTALLED PRIOR TO <br /> AND DEBRIS DEVICE CLEARING AND GRADING ACTIVITY,OR UPON <br /> PLACEMENT OF A NEW CATCH BASIN. <br /> FILTERED WATER 4. SEDIMENT SHALL BE REMOVED FROM THE UNIT <br /> 1 <br /> WHEN IT BECOMES ONE THIRD FULL OR IN <br /> ACCORDANCE WRH THE MANUFACTURES' <br /> INSTRUCTIONS. AT ONE ELEVATION <br /> FOR ENTIRE <br /> S. SEDIMENT REMOVAL SHALL BE ACCOMPLISHED BY LENGTH <br /> REMOVING THE INLET INSERTS,EMPTYING,AND <br /> RE-INSTALLING IT INTO THE CATCH BASIN.DO NOT AL GRADE <br /> WASH SEDIMENT INTO STORM DRAINS WHILE <br /> CLEANING. p <br /> M O w <br /> 6. SIZE THE BELOW INLET GRATE DEVICE(BIGD)FOR THE N 3 <br /> STORM WATER STRUCTURE IT WILL SERVICE. N <br /> ih <br /> 7. THE BIGDSHALL HAVE A BUILT-IN HIGH-FLOW RELIEF MPy" <br /> SECTION VIEW SYSTEM(OVERFLOW BYPASS). cj <br /> 8. THE RETRIEVAL SYSTEM MT REMOVAL OF <br /> THE BIGD WITHOUT SPILLINGNG THE COLLECTED <br /> COLLECTED 1 <br /> MATERIAL. Py- <br /> 9. PERFORM MAINTENANCE IN ACCORDANCE WITH <br /> RETRIEVAL SYSTEM STANDARD SPECIFICATION 8-01.3(15). <br /> 8"0 STRAW WATTLE B R I X T O N <br /> INSTALL PARALLEL TO FINISHED <br /> DRAINAGE GRATE NOTES: GRADE ALONG CONTOUR <br /> 3 <br /> n <br /> 1. INSTALL PER MANUFACTURERS RECOMMENDATION. END OF WATTLE <br /> 3 2. BUTT ENDS AGAINST EACH OTHER TO MAKE A <br /> CONTINUOUS WATTLE. <br /> 119 PINE STREET,SUITE 400 <br /> BELOW INLET GRATE WSDOT STD PLAN I-40.20-00 ACCEPTABLE SUBSTITUTE IF SEATTLE, WA 98101 <br /> C DEVICE OVERFLOW BYPASS MAINTENANCE MEETS NOTES 1-5 T 206.223.0326 <br /> TYPICAL <br /> CITY OF EVERETT www.migcom.com <br /> �s PUBLIC WORKS DEPARTMENT <br /> es TM`^•°^�^"fl '� 12/30/2016 PHASE 1 PERMIT <br /> so ISOMETRIC VIEWµ — w <br /> STORM DRAININLET <br /> ON PROTECTION 210 <br /> Q�ANf O <br /> NTSi r� T-n--.x <br /> mSTORM DRAIN INLET PROTECTION I STRAW WATTLE <br /> 7-12-23 <br /> CIVIL ENGINEER STAMP FOR EVERETT SHOPS <br /> REDEVELOPMENT APPLIES TO SHEET SET UP <br /> FOR CITY OF EVERETT AND WSDOT STANDARD <br /> DETAILS SHOWN ON THIS SHEET. DESIGN OF <br /> STANDARD DETAILS IS BY CITY OF EVERETT OR <br /> WSDOT PUBLIC WORKS OR AS NOTED ON <br /> DETAIL. <br /> CHAIN LINK TREE EX. TREE TO TREE PROTECTION NOTES: TREE PROTECTION FENCING NOTES DATE:: JANUARY 18 2023 <br /> PROTECTION FENCING BE PROTECTED 1 A TREES CRITICAL ROOT ZONE (CRZ) IS A CIRCULAR AREA WHICH HAS A RADIUS MEASURING ONE FOOT IN LENGTH FOR TREE PROTECTION ZONE 1. SIX FOOT HIGH TEMPORARY CHAINLINK FENCE SHALL BE PLACED AT TREE <br /> EVERY INCH OF TRUNK DIAMETER TAKEN AT 54 INCHES ABOVE GRADE AT BASE OF TREE. ACTUAL LIMITS OF A TREE'S CRZ PER PLANS AND SPECS PROTECTION ZONE OF TREES TO BE SAVED UNLESS OTHERWISE INDICATED. FENCE REVISION <br /> ARBORIST WOOD ( ) 1 04/19/2023 PW2301-012 Revisions <br /> WATER BARRELS CHIP MULCH. WILL VARY BOTH IN DEPTH AND SPREAD DEPENDING ON SIZE OF TREE, SOILS, WATER TABLE, SPECIES AND OTHER FACTORS. SHALL COMPLETELY ENCIRCLE TREE(S) UNLESS OTHERWISE INDICATED. INSTALL FENCE <br /> 4" DEPTH. NO IF THE DRIP LINE IS GREATER THAN THE CRZ, USE THE DRIP LINE AS THE CRZ. THE CRZ MAY EXTEND BEYOND TREE POSTS USING PIER BLOCKS ONLY, AVOID DRIVING POSTS OR STAKES INTO ROOTS. 2 07113/2023 PW2301-012 Revisions <br /> DRIPLINE MULCH WITHIN PROTECTION FENCING. <br /> 2' OF TREE DIAMETER BREAST HEIGHT (DBH*) = DIAMETER OF A TRUNK AS MEASURED AT A HEIGHT 54 INCHES ABOVE THE GROUND LINE. g 7n 2. TREE PROTECTION FENCING TO BE IN PLACE BEFORE ANY PHYSICAL WORK TAKES <br /> TRUNK. <br /> PLACE ON SITE. <br /> 2. WHEN WORKING WITHIN THE TREE'S PROTECTION CRITICAL ROOT ZONE, AN ARBORIST SHALL BE PRESENT. <br /> TREE ROOT I 3. FENCES SHALL ONLY BE ADJUSTED TO AVOID BLOCKING ACTIVE SIDEWALKS AND <br /> PROTECTION 3. NO STOCKPILING OF MATERIAL, VEHICULAR TRAFFIC OR STORAGE OF EQUIPMENT OR MACHINERY SHALL BE ALLOWED WITHIN TOP SHALL REMAIN IN PLACE UNTIL THE IMPROVEMENTS WITHIN THE RIGHT—OF—WAY <br /> y�L FABRIC THE CRZ REGARDLESS OF FENCE LOCATION. RAIL "� I AND/OR AFFECTED PRIVATE LOT ARE COMPLETED. <br /> 4. WORK WITHIN CRZ SHALL BE MANUAL UNLESS OTHERWISE INDICATED. IF TRENCHLINE OR OTHER WORK FALLS WITHIN THE CRZ, 4. WHERE THE TREE PROTECTION ZONE EXTENDS BEYOND THE PROPERTY LINE OR <br /> CONTRACTOR SHALL REVIEW SPECIFICATIONS AND COORDINATE REQUIREMENTS WITH AUTHORITY HAVING JURISDICTION (AHJ). AT BEYOND THE DEMOLITION LIMITS, PLACE TREE PROTECTION FENCING UP TO AND <br /> A MINIMUM, HAND DIG IN CRZ. RETAIN STRUCTURAL ROOTS (1 INCH OR GREATER) ACROSS TRENCHES. TEMPORARILY COVER = ALONG PROPERTY LINE AND/OR LIMIT LINE. <br /> *DBH ALL EXPOSED ROOTS WITH DAMP BURLAP TO PREVENT DRYING AND COVER WITH SOIL AS SOON AS POSSIBLE (28 HOUR MAX.) <br /> 2' ROOTS OVER 1 INCH DAMAGED DURING CONSTRUCTION SHALL HAVE A CLEAN, STRAIGHT CUT TO REMOVE DAMAGED PORTION 5. SEE PLANS WHERE EXISTING FENCE IS APPLIED AS TREE PROTECTION FENCING. <br /> OF ROOT. <br /> 6. TREE PROTECTION FOR TREES TO BE SAVED WITH CRZ WITHIN OR ADJACENT TO <br /> 5. WHERE SOIL ABATEMENT AND PLANTING SOIL REPLACEMENT OCCURS WITHIN THE CRZ, NO MOTORIZED EQUIPMENT SHALL BE RIGHT—OF—WAY SHALL FOLLOW THE FOLLOWING PROCEDURES: <br /> TREE PROTECTION ZONE I ALLOWED ON UNPAVED SURFACES. TEMPORARY CHAINLINK A. SPRAY OR SURVEY LINE OF IMPROVEMENTS OR PROJECT WORK. <br /> FENCE iv B. LOCATE FENCE PER DETAIL OR TO LOCATION DIRECTED BY ARBORIST. <br /> PER PLANS AND SPECIFICATIONS 6. WHERE EXISTING PAVEMENT IS TO BE REMOVED WITHIN THE CRZ, NO MOTORIZED EQUIPMENT SHALL BE ALLOWED ON UNPAVED C. FOLLOWING COMPLETION OF PROJECT WORK FENCE SHALL BE MOVED OUT TO <br /> REBAR ANCHOR PER <br /> CRZ SURFACES. FILL VOIDS WITH APPROVED SOILS. REPLACE TREE PROTECTION FENCING AFTER OPERATIONS. THE CRZ, DRIPLINE IF BEYOND CRZ, OR AS DIRECTED BY THE ARBORIST. <br /> I SPECIFICATIONS <br /> CRITICAL ROOT ZONE <br /> 7. WHERE EXISTING FOUNDATION IS TO BE REMOVED WITHIN THE CRZ, NO MOTORIZED EQUIPMENT SHALL BE ALLOWED ON <br /> UNPAVED SURFACES. FILL VOID WITH APPROVED SOILS. REPLACE TREE PROTECTION FENCE. DRAWN BY: MK SS JZ <br /> 3 <br /> CHECKED BY: MD <br /> JOB NO.: 15205 <br /> DETAILS <br /> SHEET NO.: <br /> NITS r� <br /> TREE PROTECTION AND FENCING 7 C6. '� <br />