My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
Plans
>
1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 8:58:53 AM
Creation date
4/8/2025 8:58:11 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Unit
3
Tenant Name
TRADER JOES
Permit
M2308-054
Year
2023
Notes
TI MECHANICAL WORK FOR TRADER JOES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING PACKAGED ROOFTOP UNIT (NATURAL GAS HEATING - DX COOLING) JEDA DESIGNS <br /> DESIGNING THE FUTURE <br /> PACKAGED ROOFTOP UNIT SCHEDULE - TRADER JOES <br /> SUPPLY FAN COOLING REHEAT GAS HEATING ELECTRICAL BASIS OF DESIGN 140 E.SANTA CLARA ST#13 <br /> MARK SERVICE LOCATION SYSTEM TYPE TOTAL MAX RETURN ESP MOTOR AMBIENT EDB EWB NOM SEN. TOTAL LDB LWB MAX CAP MOISTURE REMOVAL INPUT OUTPUT TEMP RISE POWER UNIT WEIGHT REMARKS ARCADIA,CA 91006 <br /> CFM CA CFM CFM BHP 'F ' F - F TONS MBH MBH IEER ISMRE 'F 'F MBH LBS/HR GAS TYPE MBH MBH 'F V/PH/HZ MCA MOCP MAKE MODEL LEIS (6(66)445 0053FA51 NE <br /> (IN. WG) (626)445-0053 FAX <br /> E)RTU-1 TRADER JOES ROOF SAV 4700 1000 3700 1.0 5.00 91 78.4 62.0 10.0 113.5 124.6 21.3 4.10 70.0 58.6 101 10.1 NATURAL 373.5 298.8 62 460/3/60 33 35 CAPTIVEAIRE CASRTU3-1.500-24-12.5T-DOAS 2,377 1-18 <br /> E)RTU-2 TRADER JOES ROOF SAV 4700 1000 3700 1.0 5.00 91 78.4 62.0 10.0 113.5 124.6 21.3 4.10 70.0 58.6 101 10.1 NATURAL 373.5 298.8 62 460/3/60 33 35 CAPTIVEARE CASRTU3-1.500-24-12.5T-DOAS 2,377 1-18 <br /> EPU-3 I TRADER JOES j ROOF j SAV 4700 1000 3700 1.0 5.00 91 78.4 62.0 10.0 113.5 124.6 21.3 4.10 70.0 58.6 101 10.1 NATURAL 373.5 298.8 62 460/3/60 33 35 CAPTIVEAIRE CASRTU3-1.500-24-12.5T-DOAS 2,377 1-18 <br /> 2..E)2TU-4 TRADER JOSE ROOF SAV 4000 1500 2500 1.0 5.0 91 78.4 62.0 10.0 117 122.7 21.3 4.10 70.0 58.6 101 10.1 NATURAL 373.5 298.8 62 460/3/60 33 35 CAPTIVEAIRE CASRTU3-1.500-24-12.5T-DOAS 2,377 1-18 a rip HE wwEE Ncg T-THE°r <br /> SPECIFiCATI0N5 SHALL CONS TNIU PRIMAFACIE EVIDENCE OF <br /> THE ACCE➢TANCEG TIE9E REST 10N5. <br /> NOTES: APPLIES TO ALL UNITS COPYRIGHT <br /> 1.INVERTER SCROLL COMPRESSOR WITH INTEGRATED OIL SENSOR. DIGITAL OR STAGED SCROLL NOT AN APPROVED EQUAL. SYSTEM DESCRIPTION AND REQUIREMENTS: JEDA DESIGNS2001 <br /> 2.DIRECT DRIVE PLENUM BLOWER. BELT DRIVEN BLOWERS ARE NOT ACCEPTABLE. PROVIDE THE FOLLOWING FEATURES LISTED BELOW FOR THE SYSTEM TYPES IDENTIFIED FOR EACH RTU <br /> 3.INTEGRATED MONITORING VIA CELLULAR CONNECTION BY MANUFACTURER. \ 09 REGISTERED <br /> 4.REFRIGERATION PRESSURE MONITORING ON HIGH AND LOW PRESSURE SIDE OF SYSTEM INCLUDED THROUGH DIGITAL INTERFACE. SAV: STAGED AIR VOLUME FOR RTUS WITH VARIABLE SPEED COMPRESSOR SHALL CONSIST OF MULTI-SPEED INDOOR FAN. ARCHITECT <br /> 5.EC MOTOR CONDENSING FANS FAN SPEED SHALL ADJUST TO MATCH COMPRESSOR OPERATION/STAGING. PROVIDE WITH HOT-GAS REHEAT DUANE L. BRENNEISE <br /> 6.ELECTRONIC EXPANSION VALVE. TXV NOT ACCEPTABLE. ADAPTIVE DEHUMIDIFICATION SYSTEM, COIL, HUMIDISTAT, AND CONTROLS. UNITS SHALL HAVE COOLING CAPACITY STATE OF WASHINGTON <br /> 7.SUCTION LINE ACCUMULATOR. CONTROLLED IN RESPONSE TO SPACE TEMPERATURE PER WSEC C403.8.5.1 <br /> 8.FACTORY COMMISSIONING WITH 5 YEAR PARTS WARRANTY, 25 YEAR WARRANTY ON STAINLESS STEEL HEAT EXCHANGERS. SEAL: <br /> 9•AVERAGE INTAKE, EVAP AND DISCHARGE TEMPERATURE SENSORS (DISCHARGE SENSOR TO BE FACTORY MOUNTED WITHIN UNIT). pACHiK <br /> 10.2" EXTERIOR DUAL-WALL CONSTRUCITON W/ R-13 INSULATION-MINIMUM 20GA EXTERIOR W/ 14GA BASE. m���°�MIS 4 <br /> 0 <br /> 11.80% EFFICIENT FURNACE, WITH MODULATING INDUCER TO MAINTAIN CONSTANT COMBUSTION EFFICIENCY ACROSS FIRING RANGE. 15:1 TURNDOWN WITH NG AND 12:1 TURNDOWN WITH LP <br /> 12.SUPPLY CFM MONITORING INTEGRAL TO UNIT WITH CFM MEASUREMENT INCLUDED THROUGH DIGITAL INTERFACE. 45 <br /> 13.FULLY MODULATING HOT GAS REHEAT. L A�ON N <br /> 14.15 DEGREE LOW AMBIENT OPERATION. 01-24-2023 <br /> 15.DOWN DISCHARGE/DOWN RETURN. SEAL: <br /> 16 PROVIDE TEMPORARY MANUAL THERMOSTAT FOR STARTUP AND TENANT USE <br /> 17 RETURN AND OUTSIDE AIR DAMPERS SHALL BE MOTORIZED, CLASS 1 LOW-LEAKAGE TYPE <br /> 18 FACTORY PROVIDED SENSIBLE, HIGH PERFORMANCE OUTSIDE AIR ECONOMIZER WITH FAULT DIAGNOSTICS PER CODE <br /> N <br /> AIR CURTAINS FANS W <br /> � k <br /> ELECTRICAL U uu) <br /> MANUFACTURER/ LOCATION/ MOTOR HEATING 0 ER. MARK LOCATION AREA MAX. MANUFACTURER CFM ESP FAN METHOD OF CONTROL LBS REMARKS <br /> MARK MODEL MOUNTING HP CAP. DELTA MAX. MCA MOCP VOLTS WT, DIMENSIONAL REMARKS SERVED MODEL NO. RPM HP V/PH/60HZ <br /> (KW) (T'F) CFM /PHASE (LBS,) DATA <br /> 5 <br /> CUR LOADING DOCK/ (E)EFEF1 ROOF/ GREENHECK/ 2100 0.5 1200 1 208/1 TEMPERATURE SENSOR SET AT 100 1 2 4 5 7 z <br /> 1 MARS STANDARD 2 ROLL-UP DOOR (2) 1/2 HP NA NA 2884 1.6 20 460/3 225 96" WIDE DOOR 2 3 a s s 7 s EQUIPMENT MEZZ G-163-VG 80 DEG F. COOLING ONLY <br /> (E)EF-2 ROOF/ GREENHECK/ 2200 0.25 1695 3/4 208/1 EXISTING CO/NO2 AND 70 1 2 4 5 7 ro <br /> CUR MARS STANDARD 2 MAIN ENTRANCE/(2) 1/2 HP 12 13 2884 62.6 70 208/1 225 96" WIDE DOOR z s a s s T LOADING DOCK CUE-130-VG OCCUPANCY OPERATION <br /> 2 FROM STRUCTURE EF ROOF/ GREENHECK/ RUNS OCCUPIED <br /> CUR MAIN ENTRANCE/ 200 0.4 1177 1/6 115/1 40 1 2 4 5 7 o <br /> 3 MARS STANDARD 2 FROM STRUCTURE(2) 1/2 HP 12 13 2884 62.6 70 208/1 225 96" WIDE DOOR t 2 3 4 5 s 3 MOP SINK G-095-VG HOURS <br /> EXIT ONLY/ EF CEILING MOUNTED/ GREENHECK/ 95 0.44 950 80 W 115/1 OCCUPANCY SENSOR - 1 2 3 6 z o <br /> CUR <br /> 4 MARS PHANTOM 12 FROM STRUCTURE (1) 1 HP 6 7.5 2534 33.8 40 208/1 100 48" WIDE DOOR z 3 a 5 s T B4 UNISEX BATHROOM SP-B110 ® O o <br /> EF CEILING MOUNTED/ GREENHECK/ 95 0.44 950 80 W 115/1 OCCUPANCY SENSOR - 1 2 3 6 > <br /> 5 UNISEX BATHROOM SP-B110 ® O <br /> EF CEILING MOUNTED/ GREENHECK/ 95 0.44 950 80 W 115/1 OCCUPANCY SENSOR <br /> ❑� STAINLESS STEEL FINISH ® NORMALLY CLOSED DOOR SWITCH. �i CC/MC TO REFERENCE EMS DRAWINGS TO 6 UNISEX BATHROOM SP-6110 <br /> COORDINATE SEQUENCE OF OPERATION PER N <br /> �2 FOUR (4) 1/2" THREADED INSERTS FOR TOP HEAT ON DEMAND. TRADER JOE'S STANDARDS. o <br /> MOUNTING. CONTRACTOR TO VERIFY PRIOR TO <br /> ORDERING AND SUBMIT DOOR TYPE TO © COLOR TO BE COORDINATED WITH ARCHITECT ® PROVIDE SPECIAL BRACKETING FOR ROLL-UP �1 PROVIDE FACTORY CONTROLLED ® MOTORIZED DAMPER �7 ECM MOTOR <br /> VENDOR). DURING SUBMITTAL PHASE. DOOR. DISCONNECT SWITCH N u u <br /> ❑3 1" ALUMINUM WASHABLE AIR FILTER. ❑2 GALVANIZED BIRD SCREEN �5 ROOF CURB <br /> © HUNG VIA VIBRATION ISOLATORS j <br /> �3 BACKDRAFT DAMPER -OR APPROVED EQUAL m o <br /> 0 z <br /> z <br /> AIR DEVICES DE-STRATIFICATION FANS <br /> MARK MODEL TYPE PATTERN ACCESSORIES[] FINISH REMARKS <br /> CD-1 PRICE-ASCDA CEILING SUPPLY DIFFUSER AS SHOWN O.B.D. BY ARCH. 241 <br /> 24 FACE MANUFACTURER/ LOCATION/ MAX. FLA/ VOLTS/ MAX. <br /> NECK SIZE ON FLOOR PLANS MARK MODEL SERVICE CFM WATTS PHASE/ OPER. <br /> Z DIMENSIONAL <br /> CD-2 PRICE-ASCDA CEILING SUPPLY DIFFUSER AS SHOWN O.B.D. BY ARCH. 12x12 FACE 60 H (LBS) DATA <br /> NECK SIZE ON FLOOR PLANS <br /> 9D-3 PRICE-ASCDA CEILING SUPPLY DIFFUSER AS SHOWN O.B.D. BY ARCH. 20x2O FACE DF THRU DF AIR ROW/ ATC CEILING/ 740 .25/31 120/1 16 FITS IN ATC CEILING, 19"Wx19"LX10"H <br /> NECK SIZE ON FLOOR PLANS 1 9 LA-248 TJS SALES AREA a a a a <br /> NON-DUCTED RETURN PROVIDE RETURN AIR BOOT OR FLEX NOTE: ALL APPLY w w cz <br /> ED_1 D_1 PRICE-APDDR RET/EXH DIFFUSER FIXED O.B.D. BY ARCH. DUCTWORK WITH 90 DEGREE ELBOW -INTERLOCKED WITH EMS SYSTEM VIA TEMPERATURE SENSOR. SEE EMS DRAWINGS FOR CONTROL SEQUENCE. ¢ Q Q <br /> -FANS TO BE INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. MECHANICAL CONTRACTOR TO COORDINATE lz <br /> O J <br /> LOCATION PER DRAWINGS AND CONTROLS CONTRACTOR. FANS ARE VARIABLE SPEED AND SHOULD BE ADJUSTED BASED ON J O N <br /> MANUFACTURER RECOMMENDATION AT HEIGHT HUNG. N N <br /> AIR HANDLER LABELING m <br /> Fil WHERE VOLUME DAMPER ON FLOOR PLAN DRAWING IS SHOWN DO NOT PROVIDE O.B.D. VOLUME DAMPER ON RTU GROCERY AREA - FRONT OF GROCERY AREA '.N <br /> DRAWING TAKES PRECEDENCE. 1 No w <br /> GROCERY AREA - GROCERY AREA CENTRAL <br /> RTU <br /> e W <br /> EQUAL MANUFACTURER'S: GREENHECK, KRUEGER, METAL-AIRE, 71TUS, NAILOR O U <br /> MRTU GROCERY AREA - BACK OF HOUSE M' J <br /> 3 LLJ <br /> �jaN U _J <br /> RTU BACK AREA z <br /> 4 Q m <br /> Awe z W <br /> w U = <br /> w w U <br /> N :�i ,f)^ <br /> L City of Everett Permit Review N � <br /> EVERETT Status:Reviewed for Permit <br /> 09/26/2023 10:32:00 AM w <br /> U <br /> z <br /> 92 w W <br /> O w <br /> M -02 <br /> d N <br /> 1415 Park Ave.W.,Denver,CO 80205 <br /> p 303.357.1998 <br /> 3.....Itingengineers.mm <br />
The URL can be used to link to this page
Your browser does not support the video tag.