1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
Plans
>
1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 8:58:53 AM
Creation date
4/8/2025 8:58:11 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Unit
3
Tenant Name
TRADER JOES
Permit
M2308-054
Year
2023
Notes
TI MECHANICAL WORK FOR TRADER JOES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENTILATION REQUIREMENTS <br /> HVAC NOTES JEDA DESIGNS <br /> PROVIDE 8"0 GOOSENECK EXHAUST DUCT PER DETAIL. <br /> DESIGNING THE FUTURE <br /> EXISTING RTU-1,2,3: OUTDOOR AIR VENTILATION CALCULATION AT <br /> OF 10'-0"A�2 ALL EXHAUST AND PLUMBING VENTS MUST BE MINIMUM <br /> WAY FROM ALL OUTSIDE AIR INTAKEE S. <br /> A� Ra P� RE, E� CODE: Vow(Rp*P.+P WA.)/E. % OUTSIDE <br /> OCCUPANT EXHAUST MINIMUM CFM �3 EXISTING SHOWN ROOFTOP UNITS ARE SHOWN IN 140 E.SANTA CLARA ST#13 <br /> ROOM NAME <br /> OCCUPANCY DENSITY ZONE AIR TOTAL SPECIFIED ON MINIMUM OUTSIDE AIR REQUIRED BY CFM SHOWN AIR APPROXIMATE LOCATIONS BASED ON EXISTING DRAWINGS. ARCADIA,CA 91006 <br /> CLASSIFICATION FTC CFM/ FT # People CFM/ PERSON DISTANCE EXHAUST ON PLANS REQUIRED 2N CONTRACTOR TO CONFIRM EXACT LOCATIONS PRIOR TO BID (626)445-0051 PHONE <br /> (#/1000 FTC) EFFECTIVENESS (CFM) PLANS (GETS) REQUIRED(CFM) CODE ROOM AND/OR INSTALLATION. <br /> � (626)445-0053 FAX <br /> GROCERY AREA+ <br /> CONNECTED SUPERMARKET 9700 0.06 8 77.6 7.5 0.8 0 0 1455 14051.71233 14100 10.321_ ® CONCENTRIC VENT FROM SEALED COMBUSTION WATER <br /> CORRIDOR HEATER.SIZE AND INSTALL PER MANUFACTURER'S <br /> TOTAL INSTALLATION INSTRUCTIONS.KEEP A MINIMUM 15'-0"AWAY <br /> oumsxDE AIR % OUTSIDE FROM OUTSIDE AIR INTAKES AND A MINIMUM 3'-0*AWAY REPAREDAND°N&�o"mNEREOE5EAI�ssLYMRED <br /> 1455 AIR OF 10.3596 FROM EXHAUST FANS. TN—I E,NEUMR REPRMUC'NON ORPue<IDAnox errNr <br /> REQUIRED ETHOD,IN WHOLE MIN PART,SPROHIETED.TTLETOTHE <br /> EQUIPMENT <br /> (CFM): SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF <br /> TOTAL THE A(—ANCE OF THESE RE DTlONS. <br /> OUTSIDE AIR EQUIPMENT COPYRIGHT <br /> SPECIFIED 1460 TOTAL SUPPLY 14100 JEDA DESIGNS 2001 <br /> (CFM): (CFM): <br /> /S REGISTERED <br /> EXISTING RTU-4: OUTDOOR AIR VENTILATION CALCULATION ARCHITECT <br /> Az Ra P., RL, Ez CODE: Voz(R*Pz+Ra*Az)/Ez $ OUTSIDE DUANE L. BRENNEISE <br /> OCCUPANT EXHAUST P MINIMUM CFM <br /> OCCUPANCY ZONE AIR TOTAL CFM SHOWN AIR STATE OF WASHINGTON <br /> ROOM NAME DENSITY SPECIFIED ON MINIMUM OUTSIDE AIR REQUIRED BY <br /> CLASSIFICATION FT CFM/ FT z # People CFM/ PERSON DISTANCE EXHAUST ON PLANS REQUIRED IN <br /> (#/1000 FT ) EFFECTIVENESS (CFM) PLANS (CFM) REQUIRED(CFM) CODE ROOM <br /> SEAL: <br /> RECEIVING AREA STORAGE 1348 0.12 0 0 5 0.8 0 0 202.2 2310.857143 3500 5.78% <br /> BREAKROOM BREAKROOM 250 0.06 30 9 5 0.8 0 0 43.75 500 500 8.75% `�FACgI,(. <br /> TOTAL J �5 WA 9,�A,,. . <br /> OUTSIDE <br /> OUTSIDE AIR <br /> 350 AIR OF 8.751 <br /> REQUIRED EQUIPMENT ~ T <br /> (CFM): m45 <br /> TOTAt AIR <br /> EQUIPMENT / fsS)pNAL <br /> OUTSIDE <br /> SPECIFIED 350 TOTAL SUPPLY 4000 <br /> 01-24-2023 <br /> (CFM): (CFM): SEAL: <br /> 8 7 6 5 4 3 2Du <br /> 1k <br /> U Y <br /> U <br /> L <br /> V <br /> 5 <br /> ID <br /> z <br /> 0 <br /> ro <br /> m <br /> o <br /> C) N <br /> z p <br /> O o <br /> N <br /> > <br /> D � <br /> II , 2 I I Z <br /> II IQ II N <br /> II IIII II � <br /> II IIII II <br /> II IIII II � <br /> II IIII - w w <br /> I L m m <br /> jIl (E)EFEF1 <br /> m <br /> III m p <br /> I I I II� I I Tu 0 3 U <br /> II Ip <br /> IN U <br /> _---- <br /> 1I I I I I I I (E)RTU-1 3 <br /> 490 CFM <br /> (E)EFEF2I OUTSIDE AIR <br /> II II ��II <br /> ❑0 �J � � <br /> II II II rr-=== <br /> II II II II <br /> II II IL_L=—J <br /> II II <br /> II II <br /> 3F 1 a a a a <br /> 200 J O <br /> II II <br /> II II <br /> II II � <br /> II II <br /> m <br /> II II <br /> _m <br /> III � N(E)RTU-2❑3 o <br /> 490 CFM O <br /> OUTSIDE AIR <br /> I I Q J <br /> II <br /> ❑3 (E)RTU-4 Q N U Q <br /> 350 OUTSIDE AIR W Q <br /> Awc <br /> City of Everett Permit Review LL- <br /> w 3 � O <br /> EVERETT Status:Reviewed for Permit N W O <br /> j (E)RTU-3❑3 09/26/2023 10:32:13 AM o <br /> Nm> <br /> �II 490 CFM LL' <br /> OUTSIDE AIR 6i <br /> z <br /> o w <br /> x <br /> I I � N <br /> MECHANICAL ROOF PLAN M - 12 <br /> 1 SCALE: 1/8"=1'-0" 1415 Park Ave.W.,Denver,CO 80205 <br /> p 303.357.1998 <br /> 3consultingengineers.com <br />