HVAC NOTES JEDA DESIGNS <br /> ❑1 SUPPLY AND RETURN DUCT UP TO A/C EQUIPMENT ON ROOF. SEE —� <br /> ROOFTOP DETAIL FOR INSTALLATION.NEW UNITS TO HAVE SMOKE DESIGNING THE FUTURE <br /> DETECTORS AS INDICATED. <br /> �2 TEMPERATURE SENSOR AND HUMIDITY SENSOR TO BE INSTALLED AT <br /> 6'-6"A.F.F.BY CONTROLS CONTRACTOR(SHOWN ON DRAWING FOR 140 E.SANTA CLARA ST#13 <br /> REFERENCE ONLY AND GENERAL LOCATION).CONTROLS CONTRACTOR TO ARCADIA,CA 91006 <br /> INSTALL IN GENERAL LOCATION.TYPICAL. (626)445-0051 PHONE <br /> (626)445-0053 FAX <br /> ❑s ALL BALANCING DAMPERS MUST BE ACCESSIBLE. TYPICAL. <br /> SEE DETAILS C AND D ON SHEET M2.1 FOR UNDER CASE RETURN DUCT. <br /> TYPICAL-2. THE USE OF THESE PLANE AND SPECIFICATIONS E= <br /> ❑s SIZE AND INSTALL(SEALED COMBUSTION)HOT WATER COMBUSTION TO UCHIE,IN WNEURRRE"RODTO`SS°So PINKICITI°NMr^" <br /> E T HE <br /> FLUE EXHAUST AND INTAKE PER MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS.TERMINATE WITH THROUGH ROOF WITH CONCENTRIC VENT SPECIFICADOuSHALLCON`sn,�valMAFACIEEVioiNCEOF <br /> AND A MINIMUM 3 FEET AWAY FROM EXHAUST FAN ON ROOF. THE CCE➢-CE OF THESE IVESTRINTIONS. <br /> COPYRIGHT <br /> © BACKDRAFT DAMPERS ARE PROVIDED FOR EACH EXHAUST FAN TO JEDA DESIGNS 2001 <br /> PREVENT BACKDRAFT WHEN ONE FAN IS OFF AND THE OTHER ONE IS <br /> RUNNING PER SCHEDULE ON SHEET MO.2.PROVIDE BACKDRAFT DAMPER <br /> 7 FOR 8"0 DUCT VERTICAL DUCT ABOVE ROOFUNE.6"0 DUCTS TO REGISTERED <br /> 8 I 6 5 4 3 2 1 ATTACH TO 8'0 DUCT WITH 45 DEGREE FirnNG IN DIRECTION OF FLOW. ARCHITECT <br /> Q TERMINATE AT ROOF WITH GOOSENECK PER DETAIL <br /> DUANE L. BRENNEISE <br /> ® HANG NA VIBRATION ISOLATORS. STATE OF WASHINGTON <br /> 0 RETURN AS MUCH AIR AS POSSIBLE THROUGH BOTTOM OF UNDER <br /> CASING AS POSSIBLE BEFORE NOISE BECOMES A CONCERN.USE <br /> BALANCING DAMPERS ON RETURN DUCT TO LIMIT AIRFLOW THROUGH <br /> RETURN DIFFUSERS SO THAT MOST OF THE RETURN AIR IS RETURNED PACH/� <br /> I THROUGH BOTTOM OF UNDER CASING. 0�J`o�WA 4 <br /> 0 <br /> I <br /> SS�ONAU�' <br /> 01-24-2023 <br /> / - - - - - SEAL: <br /> � / I <br /> X <br /> F CUR 8/ U U DF <br /> E)I f 9 2 <br /> ( J yl�////i� i,i i <br /> — -01 ExiT D <br /> (E)UH S FT.REF CASE SFT.REF CASE <br /> Oz a <br /> ❑ CUR 8 m <br /> I <br /> 3 <br /> EF l I O <br /> 530 & W O Y <br /> 4 -j Q 6-UP I <br /> 95 12"0 L,oo i <br /> TYP.9 Eff <br /> EF o g <br /> / 96 1 22x22 54x10 ❑9 U� OF a L <br /> EF TYP.3 tln 1 m <br /> 6/ (E)RTU-1(E)EG1 95 DN h ry 2� ON ROOF III DF w o <br /> 1100 CFM W N <br /> x - 1 2 1 Q <br /> / C 2 70 N CDCD1 12x6 10'0 22x16 22z16 ❑ IIII ON ROOF N <br /> (E)EF1 � o <br /> 6"0 470 <br /> TYP.2 12"0 <br /> DN 200 2 ^ N z <br /> II-_!I-_Lull s <br /> D- -_- ON ROOF RD-1 - N <br /> -12"0 1 f 1 2 CUR 8 5 --- O <br /> U <br /> w w <br /> 9 4 till a m m <br /> 1 14�f EQUIPMENT PLATFORM <br /> - S )RTU-2 m <br /> 1270 I RD_t ON ROOF O z <br /> CUR 8 22x22 30A2 DF MECHANICAL UTILITY ROOM FLOOR PLAN w <br /> — a 1 Q TYP.3 6 — — 3 — SCALE: 1/8"=1'-0" <br /> U <br /> lilt <br /> L s �t <br /> 200 <br /> 0 <br /> L_ IIII <br /> — II i 10'f <br /> II II I <br /> L_ _-1 _�1 _� Till 0 a L =�II <br /> L I I (E)RTU-4 R� 10.0 N <br /> 75p L 7ililh JL- JL -J 2 ON ROOF a 22x22 TYP 12 <br /> 12110 12'0 <br /> a w <br /> L—JL—-IL---JL--1 54x1 <br /> o iiil E)RTU-3 Q Q Q <br /> i 1 ON ROOF �1 DF p <br /> 4 O <br /> 0 34x °IRIE, <br /> 14 T U ~ <br /> 20x12 ---''� � <br /> 38x16 S p1AVI <br /> � 37p IIII II <br /> II <br /> 10' m <br /> TYR 3 a <br /> N <br /> T:ET.REF,CASE ER CASE S Fr.R.I.CASE <br /> W~ <br /> N <br /> TJ'S #1391 EVERETT DF 6 REL CATION sF ti Q z <br /> 13,230 SF ,z CLI <br /> W o <br /> wo <br /> I I <br /> UJ w <br /> a <br /> U z <br /> 1 MECHANICAL FLOOR PLAN ` City of Everett Permit Review o w <br /> SCALE: 1/8"=1'-0" EVERETT Status:Reviewed for Permit <br /> ........,, a u=i <br /> 09/26/2023 10:32:09 AM <br /> 1415 Park Ave.W.,Denver,CO 802D5 <br /> p 303.357.1998 <br /> 3consuHingengineers.com <br />