1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
Plans
>
1302 SE EVERETT MALL WAY 3 2023 TRADER JOES Plans 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 8:58:53 AM
Creation date
4/8/2025 8:58:11 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Unit
3
Tenant Name
TRADER JOES
Permit
M2308-054
Year
2023
Notes
TI MECHANICAL WORK FOR TRADER JOES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES JEDA DESIGNS <br /> ❑1 SUPPLY AND RETURN DUCT UP TO A/C EQUIPMENT ON ROOF. SEE —� <br /> ROOFTOP DETAIL FOR INSTALLATION.NEW UNITS TO HAVE SMOKE DESIGNING THE FUTURE <br /> DETECTORS AS INDICATED. <br /> �2 TEMPERATURE SENSOR AND HUMIDITY SENSOR TO BE INSTALLED AT <br /> 6'-6"A.F.F.BY CONTROLS CONTRACTOR(SHOWN ON DRAWING FOR 140 E.SANTA CLARA ST#13 <br /> REFERENCE ONLY AND GENERAL LOCATION).CONTROLS CONTRACTOR TO ARCADIA,CA 91006 <br /> INSTALL IN GENERAL LOCATION.TYPICAL. (626)445-0051 PHONE <br /> (626)445-0053 FAX <br /> ❑s ALL BALANCING DAMPERS MUST BE ACCESSIBLE. TYPICAL. <br /> SEE DETAILS C AND D ON SHEET M2.1 FOR UNDER CASE RETURN DUCT. <br /> TYPICAL-2. THE USE OF THESE PLANE AND SPECIFICATIONS E= <br /> ❑s SIZE AND INSTALL(SEALED COMBUSTION)HOT WATER COMBUSTION TO UCHIE,IN WNEURRRE"RODTO`SS°So PINKICITI°NMr^" <br /> E T HE <br /> FLUE EXHAUST AND INTAKE PER MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS.TERMINATE WITH THROUGH ROOF WITH CONCENTRIC VENT SPECIFICADOuSHALLCON`sn,�valMAFACIEEVioiNCEOF <br /> AND A MINIMUM 3 FEET AWAY FROM EXHAUST FAN ON ROOF. THE CCE➢-CE OF THESE IVESTRINTIONS. <br /> COPYRIGHT <br /> © BACKDRAFT DAMPERS ARE PROVIDED FOR EACH EXHAUST FAN TO JEDA DESIGNS 2001 <br /> PREVENT BACKDRAFT WHEN ONE FAN IS OFF AND THE OTHER ONE IS <br /> RUNNING PER SCHEDULE ON SHEET MO.2.PROVIDE BACKDRAFT DAMPER <br /> 7 FOR 8"0 DUCT VERTICAL DUCT ABOVE ROOFUNE.6"0 DUCTS TO REGISTERED <br /> 8 I 6 5 4 3 2 1 ATTACH TO 8'0 DUCT WITH 45 DEGREE FirnNG IN DIRECTION OF FLOW. ARCHITECT <br /> Q TERMINATE AT ROOF WITH GOOSENECK PER DETAIL <br /> DUANE L. BRENNEISE <br /> ® HANG NA VIBRATION ISOLATORS. STATE OF WASHINGTON <br /> 0 RETURN AS MUCH AIR AS POSSIBLE THROUGH BOTTOM OF UNDER <br /> CASING AS POSSIBLE BEFORE NOISE BECOMES A CONCERN.USE <br /> BALANCING DAMPERS ON RETURN DUCT TO LIMIT AIRFLOW THROUGH <br /> RETURN DIFFUSERS SO THAT MOST OF THE RETURN AIR IS RETURNED PACH/� <br /> I THROUGH BOTTOM OF UNDER CASING. 0�J`o�WA 4 <br /> 0 <br /> I <br /> SS�ONAU�' <br /> 01-24-2023 <br /> / - - - - - SEAL: <br /> � / I <br /> X <br /> F CUR 8/ U U DF <br /> E)I f 9 2 <br /> ( J yl�////i� i,i i <br /> — -01 ExiT D <br /> (E)UH S FT.REF CASE SFT.REF CASE <br /> Oz a <br /> ❑ CUR 8 m <br /> I <br /> 3 <br /> EF l I O <br /> 530 & W O Y <br /> 4 -j Q 6-UP I <br /> 95 12"0 L,oo i <br /> TYP.9 Eff <br /> EF o g <br /> / 96 1 22x22 54x10 ❑9 U� OF a L <br /> EF TYP.3 tln 1 m <br /> 6/ (E)RTU-1(E)EG1 95 DN h ry 2� ON ROOF III DF w o <br /> 1100 CFM W N <br /> x - 1 2 1 Q <br /> / C 2 70 N CDCD1 12x6 10'0 22x16 22z16 ❑ IIII ON ROOF N <br /> (E)EF1 � o <br /> 6"0 470 <br /> TYP.2 12"0 <br /> DN 200 2 ^ N z <br /> II-_!I-_Lull s <br /> D- -_- ON ROOF RD-1 - N <br /> -12"0 1 f 1 2 CUR 8 5 --- O <br /> U <br /> w w <br /> 9 4 till a m m <br /> 1 14�f EQUIPMENT PLATFORM <br /> - S )RTU-2 m <br /> 1270 I RD_t ON ROOF O z <br /> CUR 8 22x22 30A2 DF MECHANICAL UTILITY ROOM FLOOR PLAN w <br /> — a 1 Q TYP.3 6 — — 3 — SCALE: 1/8"=1'-0" <br /> U <br /> lilt <br /> L s �t <br /> 200 <br /> 0 <br /> L_ IIII <br /> — II i 10'f <br /> II II I <br /> L_ _-1 _�1 _� Till 0 a L =�II <br /> L I I (E)RTU-4 R� 10.0 N <br /> 75p L 7ililh JL- JL -J 2 ON ROOF a 22x22 TYP 12 <br /> 12110 12'0 <br /> a w <br /> L—JL—-IL---JL--1 54x1 <br /> o iiil E)RTU-3 Q Q Q <br /> i 1 ON ROOF �1 DF p <br /> 4 O <br /> 0 34x °IRIE, <br /> 14 T U ~ <br /> 20x12 ---''� � <br /> 38x16 S p1AVI <br /> � 37p IIII II <br /> II <br /> 10' m <br /> TYR 3 a <br /> N <br /> T:ET.REF,CASE ER CASE S Fr.R.I.CASE <br /> W~ <br /> N <br /> TJ'S #1391 EVERETT DF 6 REL CATION sF ti Q z <br /> 13,230 SF ,z CLI <br /> W o <br /> wo <br /> I I <br /> UJ w <br /> a <br /> U z <br /> 1 MECHANICAL FLOOR PLAN ` City of Everett Permit Review o w <br /> SCALE: 1/8"=1'-0" EVERETT Status:Reviewed for Permit <br /> ........,, a u=i <br /> 09/26/2023 10:32:09 AM <br /> 1415 Park Ave.W.,Denver,CO 802D5 <br /> p 303.357.1998 <br /> 3consuHingengineers.com <br />