Laserfiche WebLink
8. Fire flow for this project is 2,250 gpm for all buildings in the complex. <br /> 9. Fire Alarm System -An approved automatic fire detection system shall be provided as required <br /> by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval prior <br /> to installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate <br /> trip tests, witnessed by a Fire Department Inspector, shall be performed, along with a certificate <br /> of completion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72, 2010 Edition. Installation <br /> of fire alarm components, including basic wiring, may not commence before plans are <br /> approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br /> professionally rendered, in sufficient detail, and must be internally consistent. Riser diagrams <br /> must match installation plans and load calculations. Components must be listed and approved <br /> for use together. Changes to plans must include new drawings and calculations and must be <br /> approved by the Fire Department Plan Reviewer prior to installation. Fire alarm installation is <br /> subject to field inspection by a Fire Department Inspector. An approved set of plans and the <br /> Engineering & Public Services Department electrical permit must be present for any installation <br /> inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering & Public <br /> Services Department. Electrical inspections and approval are required prior to calling for <br /> acceptance tests. Call (425) 257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing <br /> Fire Department inspection and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA <br /> 72, 2010 Edition, Chapter 10, page 114). <br /> Call for design requirements per Authority Having Jurisdiction. <br /> Automatic smoke detection is required. <br /> 10. For buildings with two or more floors, including sub-floors, the alarm system must call point-by- <br /> point reporting to an alarm center. <br /> 11. Fire Suppression (Sprinkler) System -An approved automatic suppression system shall be <br /> provided as required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal <br /> Code. The system must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering & Public Services Department <br /> for examination and approval. Such plans shall include plans for the underground mains that <br /> will supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an <br /> NFPA 13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler <br /> installation shall not begin without an approved and stamped set of plans from the <br /> Engineering & Public Services Department. The Fire Department will also review the plans <br /> and shall field inspect the installation based only on approved plans that must be on site. <br /> 3�� <br />