My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3726 BROADWAY MOUNTAIN PACIFIC BANK 2025-04-11
>
Address Records
>
BROADWAY
>
3726
>
MOUNTAIN PACIFIC BANK
>
3726 BROADWAY MOUNTAIN PACIFIC BANK 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 1:47:53 PM
Creation date
4/9/2025 9:16:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3726
Tenant Name
MOUNTAIN PACIFIC BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. Dry -Type Sprinkler Systems — Have constrictor demonstrate that both high and ❑ ❑ ❑ <br />low air pressure are supervised as required. The off -normal signal shall be initiated <br />when the pressure increases or decreases by 10 psi. <br />8. Supervised Valves - Close all electrically supervised sprinkler control valves to ❑ ❑ ❑ <br />verify supervisory alarm at the FACP within 2 turns of control wheel or, for post <br />indicator valve within 1/5 of valve control mechanism's travel distance. Then <br />reopen to verify "restore' signal. <br />9. Main Drain - Open the main drain valve, it should be able to be fully opened ❑ ❑ ❑ <br />without causing water damage. When the pressure stabilizes, note whether the <br />pressure dropped and stayed below the residual pressure on the calc plate. If it <br />does, there is a problem with the system. <br />10. Calc Plates - Hydraulic Design Information Sign (Calc Plates) shall be proved by the ❑ ❑ ❑ <br />installing contractor. The sign shall be weatherproof metal or rigid plastic secured <br />with corrosion -resistant wire, chain, or other approved means. Such signs shall be <br />placed at the alarm valve, dry pipe valve, pre -action valve, or deluge valve <br />supplying the corresponding hydraulically designed area. <br />The sign shall include the following information: <br />• Location of the design area or areas <br />• Discharge densities over the design area or areas <br />• Required flow and residual pressure demand at the base of the riser <br />• Occupancy classification or commodity classification and maximum <br />permitted storage height and configuration <br />• Hose stream allowance included in addition to the sprinkler demand <br />• The name of the installing contractor <br />11. Door Signs - Doors leading into rooms that contain controls for fire sprinklers shall ❑ ❑ ❑ <br />be identified with an approved sign. Approved signs shall identify fire protection <br />equipment and be durable martials, red and white in color, permanently installed, <br />and readily visible. <br />12. Valve Signs -All control, drain, and test connection valves shall be provided with a ❑ ❑ ❑ <br />weatherproof metal or rigid plastic identification signs, secured with corrosion - <br />resistant wire, chain, or other approved means. The sign shall identify the portion <br />of the building served and systems with more than one control valve that must be <br />closed to work on a system or space shall have a sign referring to existence and <br />location of other valves. <br />13. Caution Sign -A caution signs shall be provided with the following wording: ❑ ❑ ❑ <br />This valve controls fire protection equipment. Do not close until after fire has been <br />extinguished. Use auxiliary valves when necessary to shut off supply to auxiliary <br />equipment. CAUTION: Automatic alarm can be sounded if this valve is closed. <br />Fire Marshal's Office 1425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-6 14.13.2020 1 Page 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.