My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3726 BROADWAY MOUNTAIN PACIFIC BANK 2025-04-11
>
Address Records
>
BROADWAY
>
3726
>
MOUNTAIN PACIFIC BANK
>
3726 BROADWAY MOUNTAIN PACIFIC BANK 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 1:47:53 PM
Creation date
4/9/2025 9:16:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3726
Tenant Name
MOUNTAIN PACIFIC BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14. Painted Heads -Where sprinklers or cover plates on concealed sprinklers have ❑ ❑ ❑ <br />been painted by other than the sprinkler manufacturer, they shall be replaced. <br />15. Listings - Escutcheons used with recessed, flush -type, or concealed sprinklers shall ❑ ❑ ❑ <br />be part of a listed sprinkler assembly and be metallic or shall be listed for use <br />around a sprinkler. No caulking or glue shall be used to seal penetrations or to <br />affix the components of a recessed escutcheon or concealed cover plate. <br />16. Spare Sprinkler Cabinet- Spare Sprinkler cabinet, sprinkler wrench, and spare ❑ ❑ ❑ <br />sprinklers shall be provided. The stock of spare sprinklers shall include all types <br />and ratings installed and shall be as follows: <br />• Facilities having under 300 sprinklers — no fewer than six sprinklers <br />• Facilities having 300 to 1000 sprinklers — no fewer than 12 sprinklers <br />• Facilities having over 1000 sprinklers — no fewer than 24 sprinklers <br />(Where dry sprinklers of different lengths are installed, spare dry sprinklers shall <br />not be required, provided that a means of returning the system to service is <br />furnished.) <br />17. Sprinkler List - A list of the sprinklers installed in the property shall be posted in <br />the spare sprinkler cabinet. The list shall include the following: <br />• Sprinkler Identification Number (SIN) if equipped; or the manufacturer, <br />model, orifice, deflector type, thermal sensitivity, and pressure rating <br />• General description <br />• Quantity of each type to be contained in the cabinet <br />• Issue or revision date of the list <br />18. Sprinkler Guards - Sprinklers subject to mechanical injury shall be protected with <br />listed guards. <br />Fire Department Connection (FDC): <br />19. Assessable/Orientated -The FDC shall be assessable and arranged/orientated so <br />that a hose line can be attached to the inlets without interference. <br />20. Clear Space -A clear working space not less than 36 inches in width, 36 inches in <br />depth and 78 inches in height shall be provided. <br />21. Knox Caps - Fire department connections shall be equipped with approved Knox <br />plugs/caps. <br />22. Signs - Verify that a sign complying with the following has been provided: <br />• Metal sign with raised letters not less than 1 inch in sized. <br />• Signs shall read AUTOMATIC SPRINKLERS or STANDPIPES or TEST <br />CONNECTION or combination thereof as applicable. <br />• Where the FDC does not serve the entire building, a sign shall be provided <br />indicating the portions of the building served. (Address, Location, Zone...) <br />Fire Marshal's Office 1425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-6 <br />❑ ❑ ❑ <br />❑ ❑ ❑ <br />PASS <br />FAIL <br />N/A <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />4.13.2020 1 Page 10 <br />