Laserfiche WebLink
6.1 GROUNDS AND BUILDINGS <br /> The following sections provide a description of general conditions and features observed during the <br /> Property reconnaissance. <br /> Interior Observations <br /> Interior access was not provided to the on-Property building. The interior of two laundry rooms were <br /> observed through the windows. A floor drain was observed in each laundry room. An electric baseboard <br /> heater was observed in the upper laundry room. Tenant storage was observed in the laundry room <br /> located in the basement. <br /> Exterior Observations <br /> The Property is developed with a two-story apartment building. A floor drain was observed outside a <br /> laundry room located in the basement of the building. Eight belowground garbage cans were observed <br /> on the Property. One of the cans appeared to have an empty upside down drum stored inside of the <br /> belowground garbage can. Stormwater appears to be diverted into either the 10th Avenue right-of-way <br /> to the south or into stormwater catch basins located on the western and eastern portions of the <br /> Property. Observations made at the Property indicated that the catch basins are plumbed into the <br /> municipal storm drain. <br /> Specific conditions that may or may not constitute potential issues of environmental concern to the <br /> Property are presented in the following table.Those conditions identified are further discussed below. <br /> Issue of <br /> Item Potential <br /> Present Concern <br /> Item Yes No Description(if present) Yes No <br /> Petroleum Products None were observed on the Property or adjoining properties. <br /> X X <br /> Hazardous Substances None were observed on the Property or adjoining properties. <br /> X X <br /> Hazardous Waste No hazardous wastes were observed to be generated,stored, <br /> X or disposed of at the Property. X <br /> Landfills, Dumps No landfills or dumps were observed on the Property or <br /> X adjoining properties. X <br /> Burial Sites or Solid Waste No evidence of burial sites was observed on the Property or <br /> Disposal adjoining properties.Solid waste is disposed by Waste <br /> X Management. X <br /> Aboveground Storage Tanks None were observed on the Property or adjoining properties. <br /> (ASTs) X X <br /> Underground Storage Tanks X None were observed on the Property or adjoining properties. X <br /> Drums and Storage Areas An empty upside down drum appeared to be inside one of <br /> X the belowground garbage receptacles. X <br /> Potential PCB-Containing None was observed on the Property or adjoining properties. <br /> Equipment X X <br /> HVAC System and Fuel Heat is provided by electric baseboards. <br /> Source X X <br /> SoundEarth Strategies,Inc. 11 February 16,2015 <br />