My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6408 BEVERLY BLVD 2025-04-11
>
Address Records
>
BEVERLY BLVD
>
6408
>
6408 BEVERLY BLVD 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 11:21:40 AM
Creation date
4/11/2025 11:20:51 AM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY BLVD
Street Number
6408
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. j • HERRERA REMODEL September 14, 2022 SDA Job # 9649 10� <br /> MAIN INTERIOR Al5-WSW !SEGMENTED WALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> I <br /> 3RD) Floor Level,e.g. Roof.4TH, 3RD.2ND 1.0 Itributary width 1.0 tributary area <br /> Lt.RIJ Load Direction,e.g.Left-Right,Front-Rear 2 0 total width 2.0 total area <br /> (For Left Wall,Use Fron:-Rear Load Direction) Tributary Area(3RD) Tributary Area(3RD) <br /> TCDXI Sheathing type(T4 3A of SDPWS-20'5) 1.0 tributary width 1.0 tributary area <br /> 2 0 total width 2.0 total area <br /> 3RD/FLj Resisting Dead Load L9 Tributary Area(2ND) z Tributary Area(2ND) <br /> Shearwall Segment Lengths: Ad; Total Length= 22 5 ft o tributary width o tributary area <br /> ( 7 5 ft T 4.0 ft 11.0 ft � I j <O total width total area <br /> Tributary Area(NA) 2- <br /> o Tributary Area(NA) <br /> IV(ROOF)= 1036 lb 6377 lb z 'tributary width w tributary area <br /> ( IV(3RD FLOOR)= 11405 lb 5596 lb _i, Itotal width total area <br /> IV()= 0 lb 0 lb <br /> IV O= 0 lb 0 lb Height of Shearwall= 8 Oft Weight of Shearwali= 10 0 lbs <br /> _ <br /> Z(Wind)= 12.441 lb E(Smc)= 11,973 lb Length of Shearwall= 4 0 ft Tributary width for dead load= 75 ft <br /> ULT. v= 276 PLF ULT. V= 266 PLF Length of adjoining wall= 4.0 ft <br /> R= 65 <br /> ASD SHEAR WALL DESIGN PER AF&PA SDPWS-2015 LRFD Holdown Design? No O r= - 2 5 <br /> LILT.WIND CAPACITY:1.4 x 0.93 x 460 PLF i(2 x 0.6)=499 PLF Ductile Anchor Design? No �\ t log;k Shear Wail <br /> LILT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE 1 ' <br /> Holdown Above: UPPER FRONT&REAR - ,- ,+ (.;._i:• <br /> ASD C TOTAL= (floor above)+(this floor)= 762 lbs + '623 lbs = 2386 lbs Seismic controls-C3(ASD eq 8): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= -104 lbs - 715 lbs = 611 lbs VNirid controls-I t IASD eq.7): <br /> lnt-:ctoreu C WL=2290 lbs Unfactored T WL=5318 lbs SIMPSON DESIGNED HOLDOWN I CS 14 �i <br /> Unfactored C.EQ=2605 lbs Unfactored T.EQ=2605 lbs FOUNDATION t INTERIOR WALLS ! LSTHD8/P <br /> Untactored C DI_ 43001bs 4613 lbs ,4L ! c t-+i-�l/ 2.--'' a <br /> Unfactored C.LLSL-4613 <br /> 1 <br /> MAIN REAR I A15-WSW iSEGMENTEC W.4L` - --- _-- <br /> i <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> 3RD Floor Level,e.g.Roof,4TH, 3RD,2ND 0 0 tributary width 3 0 tributary area <br /> Lt-Rt__ Load Direction,e.g.Left-Right, Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall.Use I rout-Rear Load Direction) T-ibutary Area(3RD) Tributary Area(3RD) <br /> (,DX Sheathing type(T4.3A of SDPWS-2015) 2C.3 tributary width 20.3 �tnbutary•area <br /> 79 5 total width 79 5 total area <br /> 3RD/FL 1 Resisting Dead Load too Area(2ND) z Tributary Area(2ND) <br /> _Shearwall Segment Lengths: Adl Total Length=1 17 Oft 1 o ary tribut width a <br /> I 6 0 ft tributary area I <br /> 1 11 O ft i l I I I o total width 9 total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> XV(ROOF)= 1036 lb 6377 lb Z tributary width n tributary area <br /> XV(3RD FLOOR)= 11405 lb 5596 lb total width total area _� <br /> ZVO= Olb 0Ib <br /> IV O= 0 lb 0 lb Height of Shearwali= 8.0 ft Weight of Shearwali= I0.0Ibs <br /> Z(Wind)= 12,441 lb F(Smc)= 11,973 lb Length of Shearwall= 6 0 ft Tributary width for dead load= _3.0 ft <br /> ULT. v= 171 PLF ULT. V= 84 PLF .„ ...-«.:>i3K Length of adjoining wall_ - 4.0 ft <br /> R= --t5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? Nc 0.,:::= 275 <br /> LILT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No t71t:µk EL( (r:af''WW-'all <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE 1 <br /> Holdown Above 7 NO FLOOR ABOVE I <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 820 Ihs = 820 lbs Wind controls-Ct(ASD eq.5). <br /> ASD T TOTAL w/0 00= (floor above)+(this floor)= 0 lbs + 333 lbs = 333 lbs Wind controls--I 1;ASD eq 77 <br /> Unfactored C WL-1367 lbs Unfactored T WL=1367 lbs - NO HOLDOWNS REQUIRED I- OR11 <br /> Unfactoied C.EQ=671 lbs Unfactored T EQ=671 lbs FOUNDATION INTERIOR WALLS L _ OK_®fI, <br /> Unfactored C.DL= 812 lbs Unfactored C.LL/SL=0 lbs <br /> 12135 <br />
The URL can be used to link to this page
Your browser does not support the video tag.