My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6408 BEVERLY BLVD 2025-04-11
>
Address Records
>
BEVERLY BLVD
>
6408
>
6408 BEVERLY BLVD 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 11:21:40 AM
Creation date
4/11/2025 11:20:51 AM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY BLVD
Street Number
6408
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> HERRERA REMODEL September 14, 2022 SDA Job # 9649 11 <br /> • MAIN LEFT I A-...:: WSW !SEGMENTED WAS:.. .� _ �.- <br /> Floes tiifo Tributary Area(ROOF) 'Tributary Area(ROOF) <br /> 3RD I Floor Level,e.g. Roof,4TH,3RD,2ND 1 C tributary width 1 0 tributary area <br /> Ft-Pr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(3RD) 1 Ttibulary Area(3RD) <br /> COX J Sheathing type(T4.3A of SDPWS-2015) 13 0 tributary width En tributary area <br /> a^ 0 total width laptotal area <br /> RI /F L I Resisting Dead Load 0Tributary Area(2ND) z ,Tributary Area(2ND) <br /> 1 Shear—wall Segment Lengths: Adj Total Length ms. 14 3 ft o tributary width a tributary area <br /> I I .1 0 0 it 1 4 3 ft r ! I i a0 total width of total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 6377 lb z tributary width w tributary area <br /> 13280 lbN <br /> >i/13RD FLOOR)= 5683 lb 5596 lb total width total area <br /> I EV'O= Olb Olb <br /> t EV()= 0 lb 0 lb Height of Shearwa!I= 8 0 ft Weight of Shearwall= 10 0 lbs <br /> E(Wind)= 8.963 lb E(Smc)= 11.973 lb Length of Shea wa;l_ 4 3 ftTributary width for dead load= 3A ftULT. v= 242 PLF ULT. V= 348 PLF Length of adjoining wall= 4.0 f <br /> i R= 65 <br /> ASD SHEAR WALL DESIGN PER.AF&PA SDPWS-2015 LRFD Holdown Design? No a_,"1 2 5 <br /> • ULT.WIND CAPACITY:1.4 x 0.93 x 720 PLF l(2 x 0.6)=781 PLF Ductile Anchor Design? No ((10 7`the-3r Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 720 PLF 1(2 x 0.7)=478 PLF USE 2 <br /> Holdown tiL^ve[ UPPER LEFT ' .."`v. <br /> I <br /> 1 ASD C TOTAL= (floor above)+(this floor)= 531 lbs 2043 lbs = 2574 lbs Seismin controls C3(ASD an.8): <br /> ASD T TOTAL w/o D0= (floor above)+-(this floor)= 104 lbs + 1617 lbs = 1720 lbs Seismic controls T2(ASD en 10: <br /> Unf ictared C WL=2034 lbs Unfactored T, dL= 2403 lbs ; SIMPSON DESIGNED HOLDOWN: CS14 <br /> '),factored C EQ= 3412 lbs Unfactored T EQ=3412 lbs 1 FOUNDATION/INTERIOR WALLS: STI-1 S1(1/RJ <br /> i lnfactored C DL a '1424 lbs Unfactored C.LL/SL= 563 Ibs <br /> — MAIN INTERIOR ! A15-WSW ISEGMENTECs'NALL ~ <br /> ( Fleur.info Tributary Area(ROOF) Tributary Area;R001=) <br /> irt0_ Floor Level,e.g.Roof.4TH,3RU,2ND 0A tributary width 0 0 tributary area <br /> L I 1 Hr_J Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2 C total area <br /> r <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(3RD) Tributary Area(3RD) <br /> (. r`f_tX I Sheathing type(T4 3A of SDPWS-2015) '0 'tributary width ®tributary area <br /> 2 0 total width 2 0 total area <br /> i 13RD/(=Ll Resisting Dead Load L., Tributary Area(2ND) z Tributary Area(2ND) <br /> I e alwall Segment Lengths: Adj,Total Length= 25 4 ft o tributary width Li- <br /> q tributary area <br /> I 1;ft [ 3 5 ft [ 12.0 ft I 7.3 ft ! ! a0 total width 9 <br /> Htotal area <br /> o Tributary Area(NA) C-) <br /> Tributary Area(NA) <br /> `V(ROO:^)= 3280 lb 6377 lb Z tributary width w —tributary area <br /> >',/(3k0 FLOOR)__ <br /> 5663 Ib 5596 Ib total width �' _total area <br /> EVO= 0lb 0lb <br /> EV()= 0 lb 0 lb Height of Shearwall=' 8 0 ft \Neigh;of Shearwall= 100 lbs <br /> 3 E(Wind)= 6,963 lb E(Smc)= 11,973 lb Leligth of Shearwall=I 3.5 ft Tributary width for dead road E 5 ft <br /> I ULT. v= 112 PLF ULT. v= 110 PLF „ , Length of adjoining wall=L 4,0 ft <br /> 4 R= `5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? Nc D _ 2 5 <br /> 1 ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductre Anchor Design? No � 31OC)' :Shear!'Val( <br /> I ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE / ' \ <br /> I Holdown Above,r NO FLOOR ABOVE <br /> ASU C.TOTAL= (floor above)+(this floor)= 0 lbs 754 ibs = 754 lbs Seismic controls-C3(ASD ea 8): <br /> ASD T,TOTAL w/o D0= (floor above)+(this floor)= 0 lbs - 126!ha = 125 lbs Seismic controls•T2(ASD eq 10) <br /> Untactuied C.WL 898Ibs Unfactored T WL=896 lbs i NO HOLDOWNS REQUIRED 1---- OK <br /> 1 t.;ntactored C GO=382 lbs Unfactored T.EQ=882 lbs FOUNDATION/INTERIOR WALLS OK <br /> Unfactored C Dl.:� 1047 lbs Unfactored C,LL/SL=0 lbs <br /> 7 <br /> 13135 <br />
The URL can be used to link to this page
Your browser does not support the video tag.