My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1815 13TH ST SEPA 016 - 013 - PRMC NEW CLINIC BUILDING Land Use Decision Documents 2025-04-21
>
Address Records
>
13TH ST
>
1815
>
SEPA 016 - 013 - PRMC NEW CLINIC BUILDING
>
Land Use Decision Documents
>
1815 13TH ST SEPA 016 - 013 - PRMC NEW CLINIC BUILDING Land Use Decision Documents 2025-04-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2025 3:49:54 PM
Creation date
4/14/2025 7:20:12 AM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1815
Tenant Name
SEPA 016 - 013 - PRMC NEW CLINIC BUILDING
Address Document Type
Land Use Decision Documents
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. Floors and sub -floors at or above grade in buildings (other than parking garages) shall be marked with <br />numbers, in ascending order, beginning with the number 1" (for the ground floor or first floor), then "2", <br />"Y, etc. Letters shall be used only to designate specific areas as detailed below. <br />Floors below grade in buildings (other than parking garages) shall be marked with the letter "B" (when <br />there is only one floor below grade). When there is more than one floor below grade, they shall be <br />marked with the letter "B" followed by numbers, in descending order, beginning with the number 1" (for <br />the floor immediately below the ground floor or first floor), then "2", "Y, etc. Example — "B1", "132", "BY, <br />in descending order. <br />Mezzanines shall be marked with the letter "M". When there is more than one mezzanine, they shall be <br />marked with the letter "M" followed by numbers, in ascending order. Example — "MV, "M2", etc. <br />Parking garages shall use the letter "P" to designate floors. <br />When there is only one parking level at or above grade, it shall be marked with the letter "P". When <br />there is more than one parking level at or above grade, they shall be marked with the letter "P" followed <br />by numbers, in ascending order. Example — "P1" "P2", etc. <br />When there is only one parking level below grade, it shall be marked "P01". When there is more than <br />one parking level below grade, they shall be marked with the letter "P" followed by numbers, in <br />descending order. Example — "P01", "P02", etc. <br />Large parking structures may use letters to designate columns for ease of locating automobiles. <br />Example — "Floor P3, Column E". <br />17. A floor map shall be included at each stair landing (11" x 17" size) and at each elevator landing (16" x <br />20" size) showing the layout and room numbering of the floor. <br />18. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with <br />standard man door access. Locations shall be approved by the Fire Code Official (NFPA 13 8.16.4.1.3). <br />19. The location of Fire Department connections (FDC) and post indicator valves (PIV) shall be determined <br />by the Fire Code Official. If immediate outside man door access is available to the sprinkler valves <br />(risers), a PIV will not be required. On building OK. <br />20. Dumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 feet from the building (IFC <br />304.3.3 and 304.3.4, 2012 Edition). <br />21. Buildings or portions of buildings or facilities exceeding 30 feet in height above the lowest level of fire <br />department vehicle access shall be provided with approved fire apparatus access roads capable of <br />accommodating fire department aerial apparatus. Overhead utility and power lines shall not be located <br />within the aerial fire apparatus access roadway. See 2012 IFC, Appendix D, D105.1 and D105.4. <br />22. Where elevators are provided in buildings, at least one elevator shall be provided for fire department <br />emergency access to all floors. The elevator car shall be of such a size and arrangement to <br />accommodate a 24-inch by 84-inch ambulance stretcher in the horizontal, open position and shall be <br />identified by the international symbol for emergency medical services (star of life). The symbol shall not <br />be less than 3 inches high and shall be placed inside on both sides of the hoistway door frame. <br />Exception: If all stories within the building have direct, accessible egress to grade (EMC 16.01, Section <br />L; IBC 3002.4, 2012 Edition). <br />
The URL can be used to link to this page
Your browser does not support the video tag.