Automatic smoke detection is required. <br />11. For buildings with two or more floors, including sub -floors, the alarm system must call point -by -point <br />reporting to an alarm center. <br />12. An approved automatic suppression system shall be provided as required by City Ordinance No. 3021- <br />07, Chapter 16.76, of the Everett Municipal Code. The system must include a mechanical water gong <br />bell. <br />Plans for any such system shall be submitted to the Engineering & Public Services Department for <br />examination and approval. Such plans shall include plans for the underground mains that will supply the <br />sprinkler system. <br />The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA 13, <br />NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall not begin <br />without an approved and stamped set of plans from the Engineering & Public Services Department. The <br />Fire Department will also review the plans and shall field inspect the installation based only on approved <br />plans that must be on site. Changes to plans must be approved by both the Engineering & Public <br />Services and Fire Departments. <br />Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br />Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for <br />private fire mains. (Below -ground piping must be installed by Washington State Patrol Licensed <br />Underground Sprinkler line certified "U" installers. For further information, contact the State Fire <br />Marshal's Office at (360) 596-3900 or contact the Everett Fire Department at (425) 257-8124.) All such <br />tests shall be witnessed by a Fire Department inspector. Call (425) 257-8124 or (425) 257-8120 to <br />make an appointment for inspection. <br />Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br />issuance of any Certificates of Occupancy. <br />Call (425) 257-8124 for more information. <br />13. Sprinkler shutoff valves shall be provided on each floor in every building three or more stories high, <br />including below -grade floors. <br />14. Standpipe systems shall comply with NFPA 14. Standpipe systems shall be installed throughout <br />buildings where the floor level of the highest story is located more than 30 feet above the lowest level of <br />the fire department vehicle access, or where the floor level of the lowest story is located more than 30 <br />feet below the highest level of fire department vehicle access. Combination sprinkler standpipe is <br />permitted. <br />15. The Snohomish County Emergency Radio System is employed by the City of Everett Fire Department <br />emergency crews and operates at 800 MHz. Large metal -framed or metal and concrete buildings can <br />weaken the signal so that communication and, therefore, firefighter safety is compromised. This <br />structure must meet the requirements of EMC 16.03, Section 510, which specifically addresses required <br />radio system performance standards in this structure. Your attention to this feature early in the planning <br />stages will help avoid a costly, last-minute retroactive installation of radio signal amplification antennae <br />and other equipment. For details, call the Everett Fire Department Plan Reviewer at (425) 257-8124. <br />