CONCRETE OBSERVATION REPORT <br />MAYES lferracon <br />Report Number: M7231404.0002 <br />Service Date: 06/08/23 <br />Report Date: 06/09/23 <br />Client <br />Brixton Everett LLC <br />Attn: Kyle Godat <br />120 S Sierra Ave <br />Solana Beach, CA 92075 <br />Permit No.: B2208-032 <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Project <br />Everett Mall Redevelopment <br />1402 SE Everett Mall Way <br />Everett, WA <br />Project Number: M7231404 <br />General Information <br />Bayley Construction requested Mayes Terracon be on site for concrete observation of the continuous footing with <br />thickened edge and column pads. These elements are being constructed by Bayley Construction. Mayes Terracon <br />representative arrived on site at 0520 and departed at 0815. <br />The construction documents referenced for this inspection include the on -site approved plans and SSK. <br />Reinforcing Steel <br />Inspected the reinforcing steel today, prior to concrete placement. <br />Concrete Placement <br />Observed concrete placement as follows: <br />Element Location Yardage Supplier Mix ID Mix Description <br />Continuous footing Gridlines D/1-2, 1/A-D 30 Smokey Point 0340A Normal Weight, 4000-psi, <br />with thickened edge air -entrained concrete <br />and column pads <br />Placement Method: chute. Consolidation Method: mechanical vibrator. Protection Method: not observed. <br />Tests Performed <br />Cast a set of (4) cylinders for lab -curing and compressive strength testing. <br />The results of observation(s) for today were reported to Bayley Construction. <br />Compliance Statement <br />Based on our observations, cast -in -place concrete construction activities at the above -referenced locations <br />appeared to be completed in general accordance with the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Mayes/Terracon Rep.: David Bernier <br />Reported To: Bayley Construction <br />Contractor: Bayley Construction <br />Report Distribution: <br />(1) Brixton Everett LLC, Kyle Godat (1) Bayley Construction, Tony Betz <br />(1) City of Everett WA, Permit Services (1) Mayes Testing Engineers, Inc, <br />(1) Mayes Testing Engineers, Inc, Mike Donna Pollard <br />Mattox <br />Reviewed By: '_. V_ )_.___ <br />�/ Barry Tuttle <br />Project Field Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM004,04-29-22, Rev. 6 Page 1 of 1 <br />