My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY ULTA 2025-07-31
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
ULTA
>
1302 SE EVERETT MALL WAY ULTA 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:24:45 PM
Creation date
4/14/2025 2:30:58 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
ULTA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POST -INSTALLED ANCHORS REPORT <br />MAYES lferracon <br />Report Number: M7231404.0001 <br />Service Date: 06/02/23 <br />Report Date: 06/15/23 <br />Client <br />Brixton Everett LLC <br />Attn: Kyle Godat <br />120 S Sierra Ave <br />Solana Beach, CA 92075 <br />Permit No.: B2208-032 <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Project <br />Everett Mall Redevelopment <br />1402 SE Everett Mall Way <br />Everett, WA <br />Project Number: M7231404 <br />GENERAL INFORMATION <br />Joe Lang with Bayley requested Terracon to be on site to observe adhesive anchors being installed. <br />The construction documents referenced for this observation include: (S 3.1 and Sheet SSK-7 dated 05/03/23). <br />ANCHOR SYSTEM INFORMATION <br />The followina anchor tvoes were used durina todav's observation: <br />Anchor <br />No. <br />Lot No. <br />ICC Report <br />Adhesive <br />Expiration <br />Date <br />Time Until <br />Full Cure <br />Sheet / Detail <br />Referenced <br />1 <br />1000333076 <br />ESR-2508 <br />Set-XP22-N <br />02/13/25 <br />72 hours <br />Sheet SSK-7, S 3.1 <br />ANCHOR INSTALLATION <br />The above anchors were installed as follows: <br />Anchor <br />No. <br />Locations <br />Quantity <br />(tested / total) <br />Anchor size <br />Embedment <br />Spacing & Edge <br />Distance <br />Status* <br />1 <br />A-C.5/1 <br />138 <br />#4 <br />3" <br />24" <br />Complies <br />Holes were prepared as per manufacturer's recommended procedures; vaccum and brush used to clean holes. <br />Ambient Temperature during observation was 55°F. <br />Results of observation(s) performed today were reported to Bayley Construction. <br />COMPLIANCE STATEMENT <br />Based on our observations and testing, the above noted items appear to be in general accordance with the <br />project documents. <br />Services: Special Inspections / Materials Testing <br />Mayes/Terracon Rep.: Ruvim Kravchuk <br />Reported To: Bayley Construction <br />Contractor: <br />Report Distribution: <br />(1) Brixton Everett LLC, Kyle Godat (1) Bayley Construction, Tony Betz <br />(1) City of Everett WA, Permit Services (1) Mayes Testing Engineers, Inc, Donna Reviewed By: <br />(1) Mayes Testing Engineers, Inc, Mike Pollard <br />Mattox Barry Tuttle <br />Project Field Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively forth e use of the client indicated above and shall not be <br />reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not <br />necessarily indicative of the properties of other apparently similar or identical materials. <br />DM010, 04-29-22 Rev.3 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.