My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY ULTA 2025-07-31
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
ULTA
>
1302 SE EVERETT MALL WAY ULTA 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:24:45 PM
Creation date
4/14/2025 2:30:58 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
ULTA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code — Residential <br />Prescriptive Energy Code Compliance for All Climate Zones in Washington <br />Single Family — New & Additions (effective February 1, 2021) <br />Table 406.3 — Energy Credits (Single Family) <br />Option Description Credits: SF <br />1. EFFICIENT BUILDING ENVELOPE OPTIONS <br />Only one option from Items 1.1 through 1.7 may be selected in this category. <br />Compliance with the conductive UA targets is demonstrated using Section R402.1.4, Total UA alternative, where [1- <br />(Proposed UA/Target UA)] > the required %UA reduction <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />1.1 0.5 <br />Vertical fenestration U = 0.24 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />1.2 1.0 <br />Vertical fenestration U = 0.20 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.28 <br />Floor R-38 <br />1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 <br />under entire slab or <br />Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.25 <br />Wall R-21 plus R-4 ci <br />Floor R-38 <br />1.4 Basement wall R-21 int plus R-5 ci 1.0 <br />Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and <br />under entire slab or <br />Compliance based on Section R402.1.4: Reduce the Total conductive UA by 15% <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.22 <br />Ceiling and single -rafter or joist -vaulted R-49 advanced <br />Wood frame wall R-21 int plus R-12 ci Floor R-38 <br />1.5 Basement wall R-21 int plus R-12 ci 2.0 <br />Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and <br />under entire slab or <br />Compliance based on Section R402.1.4: Reduce the Total conductive UA by 30% <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.18 <br />Ceiling and single -rafter or joist -vaulted R-60 advanced <br />Wood frame wall R-21 int plus R-16 ci <br />1.6 Floor R-48 3.0 <br />Basement wall R-21 int plus R-16 ci <br />Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and <br />under entire slab or <br />Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. <br />Advanced framing and raised heel trusses or rafters <br />Vertical Glazing U-0.28 <br />1.7 R-49 Advanced (U-0.020) as listed in Section A102.2.1, Ceilings below a vented attic and <br />R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall <br />toD Dlate at the eaves. <br />0.5 <br />Prescriptive Path — Single Family 2018 Washington State Energy Code-R <br />
The URL can be used to link to this page
Your browser does not support the video tag.