My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY ULTA 2025-07-31
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
ULTA
>
1302 SE EVERETT MALL WAY ULTA 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:24:45 PM
Creation date
4/14/2025 2:30:58 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
ULTA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code — Residential <br />Prescriptive Energy Code Compliance for All Climate Zones in Washington <br />Single Family — New & Additions (effective February 1, 2021) <br />Table 406.3 — Energy Credits (Single Family) <br />Option Description Credits: SF <br />2. AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION OPTIONS <br />Only one option from Items 2.1 through 2.4 may be selected in this category. <br />Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour <br />maximum at 50 Pascals or <br />For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested <br />air leakage to 0.3 cfm/sf maximum at 50 Pascals and <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code or Section 403.8 of the International Mechanical Code shall <br />2.1 be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the 0.5 <br />furnace fan (if present). Ventilation systems using a furnace including an ECM motor are <br />allowed, provided that they are controlled to operate at low speed in ventilation only <br />mode. <br />To qualify to claim this credit, the building permit drawings shall specify the option being <br />selected and the maximum tested building air leakage, and shall show the qualifying <br />ventilation system and its control sequence of operation. <br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes <br />per hour maximum at 50 Pascals or <br />For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested <br />2.2 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.0 <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code or Section 403.8 of the International Mechanical Code shall <br />be met with a heat recovery ventilation system with minimum sensible heat recovery <br />efficiency of 0.65. 1 <br />Compliance based on Section R402.4.1.2: <br />Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals or <br />For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested <br />2.3 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.5 <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code or Section 403.8 of the International Mechanical Code shall <br />be met with a heat recovery ventilation system with minimum sensible heat recovery <br />efficiency of 0.75. 1 <br />Compliance based on Section R402.4.1.2: <br />Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or <br />For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested <br />2.4 air leakage to 0.15 cfm/sf maximum at 50 Pascals and 2.0 <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code or Section 403.8 of the International Mechanical Code shall <br />be met with a heat recovery ventilation system with minimum sensible heat recovery <br />efficiency of 0.80. Duct installation shall comply with Section R403.3.7. 1 <br />1 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall <br />specify the maximum tested building air leakage and shall show the heat recovery ventilation system. <br />Prescriptive Path — Single Family 2018 Washington State Energy Code-R <br />
The URL can be used to link to this page
Your browser does not support the video tag.