Laserfiche WebLink
_ 4 of 34 <br /> Cl1=1 :l <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> Nag =(ANa) W ec1,Na Wec2,Na Wed,Na WcpNa Nba ACI 318-14 Eq.(17.4.5.1b) <br /> AA <br /> 4. Nag >Nua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANaO =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da V T uncr ACI 318-14 Eq.(17.4.5.1 d) <br /> 1100 <br /> 1 <br /> Wec,Na = \1 + eN/ <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> cNa <br /> W ed,Na =0.7+0.3(Ca —''inc <br /> <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> cNa <br /> W cp,Na =MAX(Cmin cNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> Cac Cac <br /> Nba = a•tkc•rz•da•het ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> T k,c,uncr[psi] da[in.] hat[in.] ca,min[in.] aoverhead Tkc[psi] <br /> 2,327 0.500 4.000 00 1.000 1,190 <br /> ec1 N[in.] ec2,N[in.] Cac[in.] A.a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> cNa[in.] ANa[in.2] ANao[in•2] W ed,Na <br /> 7.239 245.82 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Nag[lb] 4)bond 4. Nag[lb] Nua[lb] <br /> 8,765 0.650 5,697 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility) <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> `C �, 4 <br />