Laserfiche WebLink
5 of 34 <br /> MITI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> Ncbg =(AN) <br /> oc) W ec,N Wed,N Wc,N Wcp,N Nb ACI 318-14 Eq.(17.4.2.1 b) <br /> Ncbg>N. ACI 318-14 Table 17.3.1.1 <br /> ANC see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> ANao =9 hef ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> W +Z eN/ <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> ec,N = (1 <br /> 3 hef <br /> W ed,N =0.7+0.3 (1.5hefCa,min) 1.0 ACI 318-14 Eq.(17.4.2.5b) <br /> W cp,N =MAx(o_min 1.5hef) <1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> Cac Cac <br /> Na =kc A.a r hef5 ACI 318-14 Eq.(17.4.2.2a) <br /> Variables <br /> hef[in.] eCl,N[in.] eC2.N[in.] Capin[in.] W c,N <br /> 4.000 0.000 0.000 1.000 <br /> Cac[in.] ko X.a fa[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations 7 1 <br /> ANc[in.2] ANcO[In•2t W ec1,N Wec2,N Wed,N Wcp,N - Nb[lb] <br /> 174.00 144.00 1.000 1.000 1.000 1.000 8,601 <br /> Results <br /> Ncbg[lb] 4>concrete 4t Ncbg[lb] N.[lb] <br /> 10,393 0.650 6,756 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 5 <br /> ice► <br />