My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4018 GRAND AVE 2025-06-30
>
Address Records
>
GRAND AVE
>
4018
>
4018 GRAND AVE 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 10:50:35 AM
Creation date
4/16/2025 1:47:44 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
4018
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />3/6/2023 <br />3/6/2023 <br />BLDG 07-EXTERIOR <br />RAKEEB KHAN <br />APPROVAL <br />eTRAKiT Inspection Request <br />SHEAR <br />Notes: <br />3/2/2023 7:42 AM Matthew Achurra <br />also ck on straps that were missing on previous inspection <br />Contact Name: Matthew Achurra <br />Site Address: 4018 GRAND AVE <br />Phone:2068193048 <br />e-Mail: jmachurra@gmail.com <br />Straps installed <br />3/6/2023 <br />3/6/2023 <br />BLDG 10-DRYWALL <br />RAKEEB KHAN <br />PARTIAL <br />as noted <br />NAILING <br />APPROVAL <br />Notes: <br />Exterior fire rated walls only. Eaves not fire rated at time. Talk to designer regarding ventilation at eaves. <br />PERMIT EXTENSION <br />EXTENSION <br />5/10/2023 <br />5/10/2023 <br />(REASON <br />Unassigned <br />REQUIRED) <br />APPROVED <br />Notes: <br />WORK AND SUPPLY SHORTAGE <br />EXTENDED THRU 11/6/2023 <br />PERMIT EXTENSION <br />SHARON <br />EXTENSION <br />10/31/2023 <br />10/31/2023 <br />(REASON <br />REQUIRED) <br />GILFEATHER <br />APPROVED <br />Notes: <br />not finished <br />11/1/2023 <br />11/1/2023 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />jmachurra@gmail.com <br />206-819-3048 <br />Corrections are not Exhaustive: <br />Install nail plates over all DWV and water piping within 1" of stud face and 11/2" beyond outside of pipe per UPC 312.9 Steel Nail Plates <br />Grade all piping at 2% slope per the UPC 708.1 General. (Specifically all drains in crawlspace. Laundry drain is completely flat.) <br />Support all drains in crawlspace every 4' horizontally per UPC 313.3 <br />Use proper drainage fittings on all drains and vents below flood level per the UPC 905.3 Vent pipe Rise, 706.0 Changes in direction of flow. <br />Vent for master shower must take of above centerline of drain per UPC 905.2 Horizontal Drain Pipe, 905.3. Also use proper long turns and medium <br />turn 90's for venting below flood rim. <br />Cannot use San tee on back for venting toilet in crawlspace, must be approved combo fitting per UPC 905.3 <br />Large section of building drain in crawlspace was buried without inspection. Uncover for next inspection for verification of no leaks, grade, and proper <br />fittings. Per UPC 105.2.1 Uncovering <br />Where a drainage or plumbing system, building sewer, private sewage disposal system, or part thereof, which is installed, altered, or repaired, is <br />covered or concealed before being inspected, tested, and approved as prescribed in this code, it shall be uncovered for inspection after notice to <br />uncover the work has been issued to the responsible person by the Authority Having Jurisdiction <br />Building drain cannot be directly under building support pad/post in crawlspace. Per UPC 312.1 General <br />312.2 Installation <br />Piping in connection with a plumbing system shall be so installed that piping or connections will not be subject to undue strains or stresses, and <br />provisions shall be made for expansion, contraction, and structural settlement. No plumbing piping shall be directly embedded in concrete or masonry. <br />No structural member shall be seriously weakened or impaired by cutting, notching, or otherwise, as defined in the building code. <br />- Install a two way cleanout on exterior of building to accommodate for an end of line cleanout per UPC 707.4 An approved type of two-way cleanout <br />fitting, installed inside the building wall near the connection between the building drain and the building sewer or installed outside of a building at the <br />I <br />Printed: Tuesday, 15 April, 2025 5 of 10 rk <br />SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.