Laserfiche WebLink
VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />lower end of a building drain and extended to grade, shall be permitted to be substituted for an upper terminal cleanout. <br />- Install above floor cleanout on kitchen drain just below trap arm per UPC 707.4 <br />12/13/2023 <br />12/13/2023 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />eTRAKiT Inspection Request <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />12/12/2023 12:08 PM Matthew Achurra <br />Contact Name: Matthew Achurra <br />Site Address: 4018 GRAND AVE <br />Phone:2068193048 <br />e-Mail: jmachurra@gmail.com <br />- Leaking 90 on vent for AW in downstairs ceiling. Leak on 3" drain in crawlspace.- Finish installing nail plates.- Back -graded drains in crawlspace. <br />Washing machine drain and main drain.- Use appropriate drainage fittings for vents below flood level. Upstairs toilet vent in downstairs ceiling, <br />downstairs toilet in crawlspace, upstairs shower in downstairs ceiling.- Use long turn 90 for vertical to horizontal drain in crawlspace for kitchen <br />drain.*** Ok to do horizontal wet vent on downstairs toilet and lav if done per code with appropriate fitting per chapter 9 of the UPC. <br />1/2/2024 <br />1/2/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />12/29/2023 2:08 PM Matthew Achurra <br />Contact Name: Matthew Achurra <br />Site Address: 4018 GRAND AVE <br />Phone:2068193048 <br />e-Mail: jmachurra@gmail.com <br />- Fix non code wet vent on downstairs toilet in crawlspace. - Fix p trap on downstairs tub that has vent below weir of trap.- Replace non code drainage <br />fittings on upstairs toilet vent and shower vent.Corrections per UPC chapter 7,9,10. <br />3/5/2024 <br />3/5/2024 <br />PLUMB 03--ROUGH <br />JEFF M RHODE <br />CANCELLED <br />see notes <br />Notes: <br />3/4/2024 7:15 AM Matthew Achurra <br />Contact Name: Matthew Achurra <br />Site Address: 4018 GRAND AVE <br />Phone:2068193048 <br />e-Mail: jmachurra@gmail.com <br />-owner called in and requested be moved to tomorrow for conflicting schedule <br />3/6/2024 <br />3/6/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />- Upside down San tee on downstairs tub waste and overflow.- Replace short nail plates with long plates that extend at least 1.5 inches beyond outside <br />diameter of water piping. <br />I <br />Printed: Tuesday, 15 April, 2025 6 of 10 rk <br />SUPERION <br />