Laserfiche WebLink
ABBREVIATIONS <br />MATERIALS <br />SYMBOLS <br />LOCATION MAP <br />DRAWING LIST <br />& <br />AND <br />@ <br />AT <br />ADJ <br />ADJACENT <br />AESS <br />ARCHITECTURAL EXPOSED STRUCTURAL STEEL <br />AFF <br />ABOVE FINISH FLOOR <br />ALUM <br />ALUMINUM <br />APPROX <br />APPROXIMATELY <br />ARCH <br />ARCHITECTURAL <br />BD <br />BOARD <br />BLDG <br />BUILDING <br />C.O. <br />BOTTOM OF <br />CENTERLINE <br />CF/Ol <br />CONTRACTOR FURNISHED / OWNER INSTALLED <br />CJ <br />CONTROL JOINT <br />CLG <br />CEILING <br />CLR <br />CLEAR <br />CG <br />CORNER GUARD <br />CMU <br />CONCRETE MASONRY UNIT <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />CONT <br />CONTINUOUS <br />COORD <br />COORDINATE <br />CUH <br />CABINET UNIT HEATER <br />DET <br />DETAIL <br />DF <br />DRINKING FOUNTAIN <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DN <br />DOWN <br />DWG <br />DRAWING <br />EA <br />EACH <br />EL <br />ELEVATION <br />ELEC <br />ELECTRICAL <br />EJ <br />EXPANSION JOINT <br />ELEV <br />ELEVATOR <br />EQ <br />EQUAL <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />EXT <br />EXTERIOR <br />FD <br />FLOOR DRAIN <br />FE <br />FIRE EXTINGUISHER <br />FEC <br />FIRE EXTINGUISHER CABINET <br />FF <br />FINISH FLOOR <br />FHC <br />FIRE HOSE CABINET <br />FIN <br />FINISH <br />FLR <br />FLOOR <br />F.O. <br />FACE OF <br />FT <br />FEET/FOOT <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />GL <br />GLAZING <br />GYP <br />GYPSUM <br />HM <br />HOLLOW METAL <br />HORIZ <br />HORIZONTAL <br />HR <br />HOUR <br />HT <br />HEIGHT <br />INCL <br />INCLUDED <br />INSUL <br />INSULATION <br />INT <br />INTERIOR <br />JT <br />JOINT <br />LAV <br />LAVATORY <br />MAX <br />MAXIMUM <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTD <br />MOUNTED <br />MTL <br />METAL <br />NIC <br />NOT IN CONTRACT <br />NO <br />NUMBER <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />OC <br />ON CENTER <br />OD <br />OVERFLOW DRAIN <br />OF/CI <br />OWNER FURNISHED / CONTRACTOR INSTALLED <br />OF/Ol <br />OWNER FURNISHED / OWNER INSTALLED <br />OH <br />OVERHEAD <br />OPP <br />OPPOSITE <br />PTD <br />PAINTED <br />R <br />RADIUS <br />RCP <br />REFLECTED CEILING PLAN <br />RD <br />ROOF DRAIN <br />REINF <br />REINFORCING <br />REQD <br />REQUIRED <br />RM <br />ROOM <br />RO <br />ROUGH OPENING <br />SCHED <br />SCHEDULE <br />SF <br />SQUARE FOOT <br />SIM <br />SIMILAR <br />SPEC <br />SPECIFICATIONS <br />SQ <br />SQUARE <br />SS <br />STAINLESS STEEL <br />STL <br />STEEL <br />STRUCT STRUCTURAL <br />T.O. <br />TOP OF <br />TYP <br />TYPICAL <br />UNO <br />UNLESS NOTED OTHERWISE <br />UL <br />UNDERWRITERS LABORATORIES <br />VERT <br />VERTICAL <br />VIF <br />VERIFY IN FIELD <br />W/ <br />WITH <br />W/0 <br />WITHOUT <br />WD <br />WOOD <br />WOOD, BLOCKING OR SHIM <br />WOOD, CONTINUOUS <br />WOOD, FINISH OR TRIM <br />PLYWOOD <br />' <br />HARDBOARD <br />GYPSUM WALLBOARD <br />BRICK VENEER <br />l <br />PRECAST CONCRETE <br />CONCRETE, MASONRY <br />CONCRETE, POURED <br />coo°c�°ao°coo <br />00000000o000 <br />POROUS gy�pp°°°°°° <br />0�O 0000 <br />SAND <br />EARTH <br />FIREPROOFING <br />INSULATION, RIDGID <br />INSULATION, BATT <br />NEOPRENE <br />STEEL <br />ALUMINUM <br />SHEET METAL <br />HOLLOW METAL <br />ALUMINUM <br />METAL LATH AND PLASTER <br />-� GLAZING <br />CARPET <br />DIMENSIONING STANDARDS <br />EXTERIOR DIMENSIONS <br />1.BUILDING PLAN DIMENSIONS. <br />A. REFER TO 1/8" FLOOR PLANS IN A2.* SERIES FOR OVERALL BUILDING DIMENSIONS, AND <br />DIMENSION POINTS TO MAJOR CONSTRUCTION TRANSITIONS OR OTHER PRIMARY ELEMENTS. IN <br />SOME CASES ADDITIONAL DIMENSIONS MAY BE PROVIDED WHERE A TYPICAL CONDITION OCCURS, <br />OR WHERE THERE IS NO 1/2" ENLARGED PLAN PROVIDED. <br />B. REFER TO 1/2" ENLARGED PLANS IN A3.2*, A3.3* AND A3.4* SERIES FOR EXTERIOR PLAN <br />DIMENSIONS NOT INCLUDED ON THE 1/8" PLANS. 1/2" ENLARGED PLAN LOCATIONS ARE TYPICALLY <br />REFERENCED FROM 1/2" ENLARGED ELEVATIONS AND NOT THE 1/8" BUILDING PLANS. <br />2. BUILDING FLOOR HEIGHT ELEVATIONS INDICATED IN PLAN, SECTION AND ELEVATION ARE <br />BASED ON HEIGHT ABOVE SEA LEVEL, AS REFERENCED BY CIVIL DRAWINGS. <br />3. REFER TO 1/8" ROOF PLAN FOR TOP OF ROOF (T.O.ROOF) HEIGHT CONSTRUCTION. REFER TO <br />FLOOR PLANS FOR LOWER ROOFS. <br />4. REFER TO 1/2" WALL SECTIONS IN A3.2*, A3.3* AND A3.4* SERIES FOR SECTION DIMENSION <br />POINTS. <br />5. REFER TO DETAILS IN A4.* SERIES FOR PLAN AND SECTION DETAIL DIMENSIONS. <br />INTERIOR DIMENSIONS <br />1. DO NOT SCALE DRAWINGS FOR DIMENSIONAL INFORMATION; ALL ELEMENTS ON THE DRAWINGS <br />MAY NOT BE TO THE EXACT SCALE. ALL DIMENSIONS REQUIRED ARE SHOWN OR MAY BE DERIVED <br />FROM THOSE SHOWN ON THE FLOOR PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS, DETAILS, <br />SCHEDULES AND SPECIFICATIONS. <br />2. FOR ADDITIONAL DIMENSIONAL INFORMATION TO ARCHITECTURAL DOCUMENTS, SEE <br />STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DOCUMENTS. <br />3. REFER TO SYMBOLS ON THIS SHEET FOR ILLUSTRATIONS USED TO INDICATE "FACE OF" OR <br />"CENTERLINE" DIMENSIONS. <br />4. EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY, ALL THE INTERIOR RELATED <br />DIMENSIONS SHOWN ON THE ARCHITECTURAL DRAWINGS CONFORM TO THE FOLLOWING <br />CONVENTIONS: <br />A. METAL STUD AND CMU PARTITIONS AT GRID LINES ARE LOCATED WITH THE <br />CENTERLINE OF THE PARTITION ASSEMBLY AT THE GRID CENTERLINE, UNLESS NOTED <br />OTHERWISE. <br />B. DIMENSIONS SHOWN AND/OR NOTED TO THE CENTERLINE ARE MEASURED TO THE <br />CENTERLINE OF DOORS, WINDOWS, OR OTHER FEATURES INDICATED. <br />C. DIMENSIONS UTILIZING THE "FACE OF" SYMBOL ARE MEASURED TO THE FACE OF <br />PARTITION ASSEMBLY AS <br />DEFINED BY THE PARTITION SCHEDULE, EXCLUSIVE OF APPLIED FINISHES HAVING <br />THICKNESS WHICH MAY BE ADDED TO SUCH WALLS, I.E. CERAMIC TILE, ETC. EXCEPT AS <br />FOLLOWS: <br />i. UNLESS NOTED AS "CLEAR", DIMENSIONS ARE NOT MEASURED TO THE FACE OF <br />APPLIED FINISHES. <br />ii. SECOND PARTITION TAG TYPE "Z" OR DETAIL TAG IN PLANS, REPRESENTS AN <br />ADDITIONAL FINISH APPLIED TO THE SCHEDULED PARTITION, AND IS THEREFORE <br />NOT INCLUDED IN THE PLAN DIMENSION, TYP. <br />D. WHERE "CLEAR" DIMENSIONS ARE SPECIFICALLY NOTED, THE DIMENSION INDICATED IS THE <br />MINIMUM DIMENSION MEASURED TO FINISH FACES AT THE MOST CONSTRICTED POINTS WHERE <br />THE DIMENSION IS SHOWN. <br />E. WHERE DIMENSIONS ARE NOT PROVIDED ON THE FLOOR PLANS TO LOCATE DOORS, REFER TO <br />DETAILS ON SHEET A8.XX IN ORDER TO DETERMINE THE LOCATION OF DOOR OPENINGS. <br />5. AT ELEVATOR AND MECHANICAL SHAFTS, ALIGN THE INSIDE FACE OF THE SHAFT WALL <br />ASSEMBLIES WITH THE INSIDE SLAB OPENINGS, PROVIDING CLEAR DIMENSIONS WHERE <br />INDICATED. <br />6. REFER TO SHEET A8.XX FOR TYPICAL MOUNTING HEIGHTS. <br />7. WHERE WALLS AND/OR PARTITIONS OF UNEQUAL THICKNESS ABUT, ALIGN EXPOSED FACES, <br />U.N.O. <br />NORTH ARROW PROJECT NORTH <br />GRAPHIC SCALE <br />0' 1' 2' 4' <br />DRAWING TITLE <br />DRAWING IDENTIFICATION <br />1 DRAWING TITLE <br />SHEET IDENTIFICATION <br />EXTERIOR ELEVATION <br />DIRECTION VIEWED <br />1 DRAWING IDENTIFICATION <br />3.01 SHEET IDENTIFICATION <br />SECTION REFERENCE <br />DIRECTION VIEWED <br />�1 DRAWING IDENTIFICATION <br />�3.05 SHEET IDENTIFICATION <br />DETAIL REFERENCE <br />1 DRAWING IDENTIFICATION <br />4.0 SHEET IDENTIFICATION <br />INTERIOR ELEVATION <br />1 <br />DIRECTION VIEWED WITH <br />4 A7.01 2 DRAWING <br />IDENTIFICATION <br />3 SHEET IDENTIFICATION <br />GRID REFERENCE <br />1 GRID/COLUMN LINE <br />ELEVATION MARK <br />ELEVATION IDENTIFICATION <br />---------------------------- <br />FINISH ELEVATION <br />ROOM TAG <br />NAME'- ROOM NAME IDENTIFICATION <br />10; ROOM NUMBER IDENTIFICATION <br />PARTITION TAG <br />FA PARTITION CONFIGURATION <br />14 -FRAMING /CMU <br />DESIGNATION <br />PARTITION <br />SEE SHEET A8.01 DESIGNATION <br />DOOR TAG RELITE TAG <br />R-X <br />�7 <br />SEE DOOR AND RELITE TYPES AND DETAILS <br />SHEET A8.11 DOOR SCHEDULES AND DATA IN <br />SPECIFICATIONS DIV. 8 <br />GLASS TYPE TAG EQUIPMENT TAG <br />REVISION TAG CASEWORK TAG <br />Al (1331.15) <br />MATCH LINE <br />1/ A101 SHEET IDENTIFICATION <br />V A101 <br />o DIMENSION TO <br />K FACE OF: <br />� - PARTITION ASSEMBLY <br />IF - EDGE OF DOOR OPENING <br />- EDGE OF OTHER ASSEMBLY <br />- WORK POINT INDICATED ON DETAILS <br />-CENTERLINE AS SHOWN AND/OR WHERE NOTED <br />-GLASS <br />SPOT ELEVATION REFERENCE <br />ELEVATION <br />SLAB ELEVATION <br />DIFFERENCE <br />EL +100'-4" <br />EL +100'-0" T- <br />SHEET DESIGNATION LEGEND <br />> <br />< <br />rt, st <br />Q <br />GENERAL INFORMATION <br />A0.01 SYMBOLS AND ABBREVIATIONS <br />y <br />A0.02 SURVEY - NORTH <br />A0.03 SURVEY - SOUTH <br />Litlys Garden i <br />m <br />x <br />LANDSCAPE <br />L1.01 SITE PLAN <br />CIVIL <br />C1.01 SITE GRADING AND UTILITY PLAN <br />Dos Reales <br />C1.02 SITE GRADING AND UTILITY PLAN <br />_o <br />Family Mexican <br />ELECTRICAL <br />E0.00 SYMBOLS, ABBREVIATIONS, AND DRAWING LIST <br />E1.20 SITE LIGHTING PLAN - NORTH <br />E1.21 SITE LIGHTING PLAN - SOUTH <br />ARCHITECTURE <br />A3.01 ELEVATIONS, EXTERIOR <br />Everett Laundry ® <br />&Cleaners <br />c <br />x <br />n <br />G _.. <br />< rr . <br />1cih,t <br />A0 <br />LS: LIFE SAFTY 001 <br />C: CIVIL <br />L: LANDSCAPE <br />-'I- A: ARCHITECTURAL <br />l SHEET NUMBER S: STRUCTURAL <br />DRAWING GROUP M: MECHANICAL <br />DISCIPLINE P: PLUMBING <br />E: ELECTRICAL <br />G: GRAPHIC SIGNAGE <br />TD: TELECOMMUNICATIONS/DATA <br />AV: AUDIONIDEO <br />SC: SECURITY/CONTROL <br />r° y <br />z� <br />D U <br />b r <br />0 <br />J <br />s maternal Order <br />w <br />Volunteers of America <br />Food Flank Distribution C-1 <br />3tn St 13t <br />7-Eleven <br />0 <br />K <br />MountainCress <br />Credit Union Blue 4 <br />7G <br />ZIMMER GUNSUL FRASCA ARCHITECTS LLP <br />PORTLAND <br />SEATTLE <br />LOS ANGELES <br />WASHINGTON DC <br />NEW YORK <br />925 Fourth Avenue <br />Suite 2400 <br />Seattle, WA 98104 <br />T 206 623 9414 <br />F 206 623 7828 <br />www.zgf.com <br />Consultants <br />CIVIL ENGINEER <br />Magnusson Klemencic Associates <br />1301 Fifth Avenue, Suite 3200 <br />Seattle, WA 98101-2699 <br />T 206 292 1200 <br />LANDSCAPE ARCHITECT <br />Site Workshop <br />222 Eturia Street <br />Seattle, WA 98109 <br />T 206 285 3026 <br />ELECTRICAL ENGINEER <br />Stantec Consulting Services <br />4100194th Street, Suite 400 <br />Lynwood, WA 98036-4613 <br />T 206 667 0553 <br />Revisions <br />NORTH SITE <br />PROVIDENCE <br />Regional Medical Center <br />Everett <br />1700 13th Street <br />Everett, Washington 98201 <br />Drawing Title <br />SYMBOLS AND <br />ABBREVIATIONS <br />Date: <br />4/15/2016 <br />Job No: <br />S23257 <br />Drawn By: <br />JS <br />Checked By: <br />Checker <br />Drawing No. <br />A0.01 <br />SEPA <br />