Laserfiche WebLink
. SE 1 /4, NE 1 /4 SEC 1 1 , T. 28 N., R. 4 E., W.M. <br /> 1 <br /> I <br /> •1\III <br /> L1 CB 2271 TYPE I <br /> \� TEMPORARY BENCHMARK IE=273.37 NORTHERLY FLANGE BOLT ON FIRE HYDRANT I E 12'CONC S=569.50 <br /> IN THE NE QUAD OF THE INTERSECTION OF I <br /> ' 75TH Sr SW&SEAWAY BLVD I CB 2033 TYPE <br /> ELEV=575.04 GE=573.37 <br /> IE 12'HOPE N=567..93 SEWER NOTES: <br /> I L` IE 12'CONE N=567.07 <br /> IE 12'CONC E=567A7 <br /> 2'BRASS DISK WITH PUNCH, _�� A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS <br /> IN CASE.0.7'N X 0.4'W, CONE WA<K APPROXIMATE LOCATION AND WSDOT/APWA STANDARD SPECIFICATIONS. <br /> DOWN 0.3' OF EXISTING HYDRANT <br /> W ! �� B. NO PART OF THE SANITARY SEWER STSILM SHALL BE COVERED, CONCEALED OR PUT <br /> �O W ■ f CB 2037 TYPE I INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY <br /> GE=572.79 INSPECTOR. <br /> I IE 12'CONC NW=567.03 C.APPROXIMATE LOCATIONS OF EXISTING UT1LR1ES HAVE BEEN OBTAINED FROM <br /> MONUMENT EN K' IE 12'CONC 5E=567.03 <br /> UNABLE TO OPEN . AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE <br /> 5j RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY <br /> 00 �• Nf \�� ADDITIONAL UTILITIES NOT SHOWN. IF CONFUCTS WITH EXISTING UTIUTIES ARISE DURING <br /> \ ' ,, CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE PUBUC WORKS INSPECTOR AND <br /> ��� �� ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO <br /> N. COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. <br /> o I✓ p� \ \ D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBUC RIGHT—OF—WAY OR IN EASEMENTS SCALE <br /> '''--'-' \,, <br /> \\ MUST BE STAKED BY SURVEY FOR UNE AND GRADE PRIOR TO STARTING CONSTRUCTION. ■ ■ ■ ■ ■ <br /> co S \\ 20 0 20 40 <br /> ° CURB&CUTTER a C 2 00 W \ �\ FEET <br /> PROPOSE' TO SW m \ <br /> u24 TYPE I PUBUC --'�,` \ i '``� 'SIGNAL AHEAD' LAMO • \\ <br /> ICS G 2024 T DRAINAGE 1 HAPED SIGNAL AH IGN \ <br /> II 2`HO.5=571.42 FASINilk Y aus stop` \\ <br /> I 2`HO:=NE=571.40 �` \C \ <br /> 1 ' ' 4iskov � ' °``'.:;,°`` \ \\\ CB 2500 TYPE I I CONSTRUCTION NOTES: <br /> / V GE=572.43 <br /> I o p IE 12'CONC NW=566.63 <br /> lj� J�� �` ��\ \ �\ \\ E 12'CONC 5E=566.63 O1 CONNECT TO EXISTING SANITARY SEWER MAIN PER <br /> 1� p L S \\ C.O.E. STD DWG. 612. <br /> `' :' ZOJ1 <br /> I 1 S� I �' I a �5�,\ S. \\ O CONNECT TO EXISTING WATER MAIN PER C.O.E. STD <br /> 1— I .,. O 'q ``��� \ DWG. 502C. <br /> /, I I I .♦„' oo \ \ LEGEND O <br /> l �^< FIBER JUNCTION BOX 3 DOMESTIC 2" METERED WATER SERVICE FOR C.O.E. <br /> 'i �\ Oza �I O I ,�♦ •♦.♦ \ R ��`.` \ \\ STD DWG. 502B. <br /> at I\ ii:. <br /> \* \ <br /> '♦ \ O4 IRRIGATION MR. <br /> .:.-0i•\i <br /> \: \ OS DOUBLE CHECK VALVE ASSEMBLY PER C.O.E. STD <br /> G ,'� N. <br /> ♦ Mti DWG• , •♦ • 2. uD=57z.71 is \\ O 604. <br /> I m `\ •♦• \�A �`• C \ \ O 6' SEWER CLENAOUT TYPE 2 PER C.O.E. STD DWG. <br /> I u I ♦• \N. \NN <br /> \ 604. <br /> E. <br /> N., <br /> g. J , ` .\ •♦'♦ ` \ s \\ WATER NOTES: <br /> m BA`` \ CB 2526 TYPE <br /> 4 _ CO ' I •♦. C X \ - 1.50 A NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF <br /> 1 I I ♦ \ \ IEE 12°CONC NW=566.20 AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, <br /> } ,,,;, 0 I •♦ \�' �O \ IE 12'CONE 5E=566.09 ILSIING, DISINFECTION, AND RECEIPT OF SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br /> a� <br /> c 3 I I 0 �♦ \``\ \\ B. CONNECTIONS TO AND TAPS ON EXISTING MANS WILL BE MADE BY THE PUBUC <br /> 4 I I �) •♦ . WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBUC WORKS DEPARTMENT <br /> ® gI a 'J •♦ • \ m\ SHALL BE GIVEN AT I FAIT 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION.THE <br /> E W I I - • \ PUBUC WORKS DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND TIME AT <br /> - N ' �' I I ♦ O,0 \\`c \ 5.\ WHICH THE CONNECTION SHALL BE MADE. <br /> . \ <br /> g • - _ I J co p. •♦• \\ '�\ C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS. <br /> I 1 ID { m \ � ♦• �B?r D. APRE-CONSTRUCTION MEETING SHALL BE HELD WTfH THE CITY PRIOR TO THE START <br /> _ I ' WN ♦ \'� P\ APPROXIMATE LOCATION <br /> �i ' as I C: • \ OF CONSTRUCTION. THE CITY OF EVERETT PUBUC WORKS CONSTRUCTION DIVISION MUST <br /> e.Q„ 'y , \a'• /• Y:\ ♦• OF EXISTING HYDRANT BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br /> ~ I 1N 4 E ♦• s. \ E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE PUBUC <br /> L 4 I ,111\ <br /> 4 �: ♦ �Y\ \ WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS <br /> m ,p I F a ,;•��.• •♦• ♦ ��,`�`� \■ \ DURING CONSTRUCTION ON A 24 HOUR BASIS. <br /> oN s . ��•�\.�� ♦• \ ��` \ F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 78 INCHES VERTICAL SEPARATION <br /> ei.1 ■ . � •� B'�.• ♦ \ ��\` \\ BETWEEN POTABLE AND NON-POTABLE CONVEYANCE STSILMS. <br /> y" • <br /> I • �.•••\'P \ ' G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBUC WORKS DEPARTMENT <br /> o �� s (yam �G A.-Cr •.�•�.�•• ♦• \ ®r , \\ PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL <br /> I - O •••�O�\• ♦• \ �\� \ TIMES. <br /> JI ,< p �p 9�p ..••�, ♦•♦• .. ,:\\ \\\ <br /> \ ss \ <br /> N. \ <br /> '14,. -- <br /> s. • \° <br /> • <br /> ' COTTONWOOD �r I I I ' _ - \�\ Y <br /> MATC H LI N E SEE SHEET UT2 CALL 2 BUSINESS DAYS BEFORE YOU DIG ��m <br /> E 1 800 424 5555 111/ <br /> . UTILITIES UNDERGROUND LOCATION CENTER I <br /> U <br /> 1 <br /> Eti <br /> COMMUNITY TRANSIT Drawing No. <br /> Perteet Drawn By Date SCALEUT1 <br /> o� �o o 75%SUBMITTAL Desyoee By 9/27/16 Hods <br /> 425-252-7700 I 1-800-615-9900 communitytransit� NOT FOR Ch1.04 ecked By 9/27/16 Vert SEAWAY TRANSIT CENTER <br /> 2707 Colb Avenue,Suite 900 `,,,v1 `' CONSTRUCTION sheet No.e <br /> No. Date Revision By APPn BC 9/27/16 <br /> Everett,Washington 98201 ADProved By Project <br /> 0155.02 Number UTILITY PLAN <br /> in f Total <br />