|
SE 1 /4, NE 1 /4 SEC 11 , T. 28 N., R. 4 E., W.M.
<br /> MATCHLINE SEE SHEET UT1
<br /> I 1` II 1 ,fi'!.\.
<br /> '� • X ; \ `\\\\ \ \ CB 2554 TYPE II �" \ ! \ \ GE=569.20 SCALE
<br /> I = } , 0 \ \ \IE 12 CONC NW=562.92
<br /> \ "qv \ • �E 12'CONC 5E=562.79 ••■••••
<br /> `, — — mIliMIN
<br /> \, \ e\ 20 0 20 40
<br /> mop
<br /> — 11 �,I �� • �:; \. 4�\\ FEET
<br /> -**** • �\ B 2764 TYPE I
<br /> I1 �. I G� '����� ,\ \ F G 567.48
<br /> 1 1, ° \ .© P \ IEh12-GONG SW=560.64
<br /> 5fl a. K9 d• . . : 1 \ IE Gorvc sE1 ' p =I ` it CONSTRUCTION NOTES:
<br /> 'III y? S ���•�\•i� _\ \ �\ \ \\ O1 CONNECT TO EXISTING SANITARY SEWER MAIN PER
<br /> m — ��� . A v V C.O.E. STD DWG. 612.
<br /> Ili I 1111�� �{ to ee! , \\ 15"l6\\� I \
<br /> 4 a m tur oz v , �� �c --- -}- I \ \ O2CONNECT TO EXISTING WATER MAIN PER C.O.E. SID
<br /> m6 0 w . p \ ,♦ ' \ -- O —'� `\ \ DWG. sozc.
<br /> B zO< : . I y. 'Li- RFs� JJ -..,,. 1 .. 1,•„ • O DOMESTIC 2" METERED WATER SERVICE FOR C.O.E.
<br /> E 5 6 6 - ' "t �� 7 �� :\sl'AULT\74DBA:\.\*
<br /> INGDDWG. 502B.E i2 HC N=-7a.22 _§ I • IO I•IE_S'70.Oo a $ � \ O IRRIGATIONMER.1.
<br /> ., Iw �\ IRRIGATION SERVICE '� \\ OY4.1
<br /> — \\ ��.�.` � �' ' \\ `\\\ 5DOUBLECHECKVALVE ASSEMBLY PER C.O.E. STD
<br /> p 3 • m pw2'WATER SERVICE. , \ `\I f�-'! x �� _._��� \ \\ O6 6" SEWER CLEANOUT TYPE 1 PER C 0 E. STD DWG
<br /> 1 0 "' ,I less, I ' ',•,OL 1 \ r GROSS \ �'.\\\` SSMH \ 604.
<br /> v - ILAYOVER \ \ �� \ \\ CTID= \
<br /> II J \ \�� © �07 6' SEWER CLENAOUT TYPE 2 PER C.O.E. STD DWG.
<br /> rg I'll
<br /> w i \ \ 30�oz amp PVC 604.
<br /> E LA I I w $ . cN N# >
<br /> II . _
<br /> \I i I 209w 6'SANITARY SEWER SERVICE \\\ otE55712- - - o `\ � cQ4 '' 14 O \
<br /> F 4
<br /> ��� Ilii ;illI . LEGEND
<br /> V: OVER` BUS 7 b c., .4�� \ Q FIBER JUNCTION BOX
<br /> r I6
<br /> ,gym ".s::a:�.:..99:-99Wfts-^e6,. ME.^x Erx.....-.....�.a. __
<br /> mom.
<br /> ME gipriars--1"
<br /> 0 CO
<br /> s g x \
<br /> 3 _ % — — �i— �` OIC- n sea� 741E 6" PVC 2` •L4. \ \\
<br /> QQ , 07,7211 2'\ \ \
<br /> w` 1 6 1 en (TRISFORM_RS SS I560.77 A2 ��0 \` V
<br /> t ' �� (;n DRA N TO SCALE) X 11 )f )' 1( )Q )� X N ). (( II OI,A 11GP y\ \ `
<br /> m CP 7'CLF W/BARBED GTP
<br /> END OF m BP-...__,�_ TOP ON coNc O /pM
<br /> a` �- 1 tit
<br /> BRIDGEL ho C9 2362 TYPE I GP AIL" AF 6•
<br /> U - LARGE HIGH BP GE=565.60
<br /> c - VOLTAGE POLE-, 4,� IE 12-PVC SE=562.09 rW �i1,•
<br /> min
<br /> I , E,," -E--_&-- 'MINA BP 30�._ G v I I CP tIN�sW0fs Ali
<br /> w , pal©1 S°
<br /> Oz `\ CP 2697
<br /> `!° o 8"MAPLE Y
<br /> �`\ 4
<br /> 1 WATER NOTES: 6'CIF 1 .,,,,,'/6
<br /> �? \ \ I W/BARBED TOP
<br /> 8 \ A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF x
<br /> - `\ a m AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, i i6.WOF T' e•MAPLE 3?'
<br /> \ 1 TESTING, DISINFECTION. AND RECEIPT OF SATISFACTORY BACTERIOLOGICAL TEST RESULTS. / , ,r1
<br /> B. CONNECTIONS TO AND TAPS ON EXISTING MANS WILL BE MADE BY THE PUBUC
<br /> E SEWER NOTES: WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBUC WORKS DEPARTMENT
<br /> A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION. THE
<br /> t
<br /> PUBUC WORKS DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND TIME AT
<br /> AND WSDOT/APWA STANDARD SPECIFICATIONS. WHICH THE CONNECTION SHALL BE MADE.
<br /> B. NO PART OF THE SANITARY SEWER STSI LAI SHALL BE COVERED, CONCEALED OR PUT C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS.
<br /> INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY D. A PRE-CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START
<br /> H INSPECTOR. OF CONSTRUCTION. THE CITY OF EVERETT PUBUC WORKS CONSTRUCTION DIVISION MUST
<br /> u C. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION.
<br /> AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE
<br /> 0111
<br /> a E.THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE PUBUC
<br /> AEDPONSILLEFOR VERIFICATION ON SHOWN. LOCATIONS AND TO AVOID DAMAGE TO ANY WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS
<br /> 0 ADDITIONAL UTILITIES NOT IF SHALLNFIJCTS WITH EXISTING UTILITIES ARISE DURING DURING CONSTRUCTION ON A 24 HOUR BASIS. CALL 2 BUSINESS DAYS BEFORE YOU DIG Al..
<br /> F- CONSTRUCTION, THE CONTRACTOR NOTIFY THE PUBUC WORKS INSPECTOR AND
<br /> D ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION
<br /> E COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. BETWEEN POTABLE AND NON-POTABLE CONVEYANCE SYSTEMS. 1 800 424 5555
<br /> E D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBUC RIGHT-OF-WAY OR IN EASEMENTS G.ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBUC WORKS DEPARTMENT I
<br /> r3 MUST BE STAKED BY SURVEY FOR UNE AND GRADE PRIOR TO STARTING CONSTRUCTION. PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL UTILITIES UNDERGROUND LOCATION CENTER
<br /> 'e9 TIMES.
<br /> U
<br /> E COMMUNITY TRANSIT Dewing No.
<br /> ta Perteet Drawe By Date �.IF
<br /> o�`o o 75%SUBMITTAL Desgned By 9/27/t6 Har: UT2
<br /> 425-252-770011-800--615-9900 communitytran NOT FOR MIA 9/27/16 SEAWAY TRANSIT CENTER
<br /> Checked By Vert
<br /> Sheet No.
<br /> 1 2707 „ate CONSTRUCTION BC 9/27/16 Ever ttColbyWas Avenue,Suite 900 s,r,re b Approved By Project Number UTILITY PLAN
<br /> Na. Date Revision Everett,Washington 98201
<br /> 20110155.023
<br /> m By APO, of Total
<br />
|