Laserfiche WebLink
2/£i24,7:19 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY19mdWxseV9jb25kaXRpb251ZCU3Q3BkX251d19idWIsZGIuZyZOZnY9c2NjX2Z1bGx5X2NvbmR... <br /> Project Title Everett 500 Building B-Fully Insulated 2018-2018 WSEC Date Feb 09,2024 <br /> SHGC xA Calculation NEW BUILDING-FULLY CONDITIONED COMPLIES <br /> Fenestration and Opaque Door Assemblies PROPOSED TARGET <br /> Glazed Door Rough Opening Glazed Door Rough Opening <br /> Glazed Doors Assembly ID IT SHGC (SF) SHGC x A SHGC (SF) SHGC x A <br /> Swinging entrance door Glazed Doors PF<0.2 0.38 I 144.0 54.7 0.51 144.0 <br /> 44. 73.4`` <br /> _ ---- <br /> Skylight Rough Opening Skylight Rough Opening <br /> Horizontal Assembly ID PF SHGC (SF) SHGC x A SHGC (SF) SHGC x A <br /> 1.120.0 <br /> Skylights Acrylic Triple Dome Skylight 0.32 1,120.0 358.4 0.35 (1) 392. <br /> Vertical Fenestration Assembly ID PF Fenestration Rough Opening SHGC x A Fenestration Rough Opening . SHGC x A <br /> SHGC (SF) SHGC (SF) <br /> • 1,254.0 <br /> Fixed-Class AW or site built Storefront Glazing PF<0.2 0.38 1,254.0 476.5 0.38 (1) 476.5 <br /> Fixed-Class AW or site built Storefront GlazingPF<0.2 0.38 2,086.0 792.7 0.5 I 2,086.0 <br /> (1) <br /> Proposed Area Proposed SHGC x A Target Area Target SHGC x A <br /> Project Totals 8,088 3,006 8,088 3,620 <br /> • <br /> https://www.waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY19mdWxseV9jb25kaXRpb25IZCU3Q3BkX251d19idWIsZGluZyZOZnY9c2NjX2Z1 bGx5X2NvbmRpdGlv... 4/4 <br />