My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5900 36TH AVE W C BRIDGE POINT 2025-04-22
>
Address Records
>
36TH AVE W
>
5900
>
BRIDGE POINT
>
5900 36TH AVE W C BRIDGE POINT 2025-04-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2025 10:10:52 AM
Creation date
4/22/2025 10:03:25 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
5900
Unit
C
Tenant Name
BRIDGE POINT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VicoWorldwide www t co-fire.com <br /> Fire Protection Contacts y <br /> • Products <br /> Model CV-1F Grooved End <br /> Swing Check Valves <br /> General The owner is responsible for main- <br /> taining their fire protection system <br /> Description and devices in proper operating con- <br /> dition. =- <br /> A Contact the installing contrac- '- <br /> The TYCO Model CV-1F Grooved End tor or product manufacturer with any `,. <br /> Swing Check Valves are compact questions. <br /> and rugged swing-type units that <br /> allow water flow in one direction and Technical <br /> prevent flow in the opposite direction. <br /> A resilient elastomer seal facing on the Data <br /> spring-loaded clapper ensures a leak- <br /> tight seal and non-sticking operation. Approvals <br /> The Model CV-1F Check Valves are Compliance with CE Pressure <br /> designed to minimize water hammer Equipment Directive(PED)and <br /> caused by flow reversal. Standards of Engineering Practice <br /> The Model CV-1F Grooved End Swing • 2 to 12 Inch (DN50 to DN300): ® c <br /> 420 11101> <br /> Check Valves are furnished with UL and C-UL Listed, FM Approved, <br /> grooved ends and can be installed Bureau Veritas APPROVED <br /> using GRINNELL Grooved Couplings 0 • 2-1/2 to 10 Inch (DN65 to DN250): <br /> or GRINNELL Figure 71 Flange Adapt- VdSVdS Approved ers. The Model CV 1 F Check Valves Certificate No. G4060018 0.Aff) <br /> havebeendesignedwitharemovable Az <br /> cover for ease of field maintenance. Sizes For fire protection pressure rating, <br /> These valves can be installed horizon- 2 to 12 Inch(DN50 to DN300) listing and approval information,contact <br /> tally(with cover in the upward position) your TYCO representative. <br /> Maximum Working Pressure <br /> or vertically with the flow in the upward <br /> direction(Ref. Figure 3). UL/FM 300 psi (20,7 bar) Installation <br /> VdS- 16 bar <br /> A check valve maintenance kit is avail Valve Assembly Finish The Model CV-1F Grooved End Swing <br /> able to allow backflushing through a Check Valves are to be installed in <br /> fire department connection without Red, non lead paint <br /> accordance with this section: <br /> removing the Model CV-1F Grooved <br /> End Swing Check Valve from the riser. Step 1. The arrow cast on the body <br /> Refer to technical data sheet TFP1555. must point in the direction of the flow. <br /> Model CV-1F is a re-designation for Step 2. Valves installed vertically <br /> Central Figure 590F and GRINNELL must be positioned with the flow in the <br /> Figure 590F Grooved End Swing Check upward direction. <br /> Valves. Step 3. Valves installed horizontally <br /> NOTICE must be positioned with the cover <br /> facing up(Ref. Figure 3). <br /> The TYCO Model CV-1F Grooved End Step 4. Grooved end pipe couplings <br /> Swing Check Valves described herein used with the Model CV-1 F Grooved <br /> must be installed and maintained in End Swing Check Valves must be <br /> compliance with this document and installed in accordance with manufac- <br /> with the applicable standards of the turer's instructions. <br /> National Fire Protection Association <br /> (NFPA), in addition to the standards Note:Valves should be installed a rea- <br /> of any authorities having jurisdiction. sonable distance downstream from <br /> Failure to do so may impair the perfor- pumps, elbows, expanders, reducers, <br /> mance of these devices, or other similar devices to extend the <br /> Never remove any piping component valve life. Standard piping practices call <br /> nor correct or modify any piping defi for a minimum of five(5)times the pipe <br /> 0 ciencies without first de-pressurizing diameter for general use. <br /> and draining the system. Failure to do <br /> so may result in serious personal injury, <br /> property damage, and/or impaired <br /> device performance. <br /> Page 1 of 6 FEBRUARY 2016 TFP1550 <br />
The URL can be used to link to this page
Your browser does not support the video tag.