Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by 02024 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />Project: <br />Starbucks Broadway and 10th GRAPHITE Reno (230809) - 2018 WSEC <br />1010 N Broadway <br />Everett, WA 98201 <br />Date: 2024-03-19 <br />Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br />Documentation Documents Notes <br />LIGHTING SCOPE <br />C103.1 Construction Put a shell K core or tenant space (fiat build - <br />documents - General out) project. indicate if there is no lighting <br />scope included in the project. <br />NA C103.1 Construction For an alteration project, indicate if there is <br />documents - General no lighting scope included in the project. <br />LIGHTING CONTROLS <br />YES <br />C405.2 <br />Lighting controls, <br />For all lighting fixtures, indicate lighting <br />E Sheets <br />general <br />control method on plans for spaces and <br />lighting zone(s) served, or exception taken <br />C405.2. <br />Lun inaire level <br />Indicate on plans all mixtures provided with <br />Option 2 <br />lighting controls <br />LLLC in lieu of C405,2 lighting controls:. <br />(LLLC) <br />provide description of control capabilities and <br />performance parameters <br />C405.2.5. <br />Lighting in dwelling <br />Indicate method of automatic control of all <br />Item 3 <br />units (dormitory. <br />installed luminaires in dwelling units in <br />C405.2.I.I <br />hotel and all other <br />buildings other than multifantih toccupanc� <br />C405.2.3.1 <br />than multifamily) <br />or light reduction controls) <br />C 405.'_.5. <br />Lighting in sleeping <br />Indicate method of automatic off control of <br />Item '- <br />units <br />all installed luminaires in sleeping units <br />(vacancy or key card control): also refer to <br />Receptacles <br />YES <br />C405.2.3 <br />Manual controls <br />Indicate on plans the method of manual <br />E Sheets <br />C405.2.3.1 <br />lighting control, location of manual control <br />C405.2.5 <br />device and the area or specific application it <br />serves <br />YES <br />C405.2.3.1 <br />Manual interior light <br />Indicate on plans which method of manual <br />E Sheets <br />C405.2.1.1 <br />reduction controls <br />50% lighting load reduction is provided, or <br />C405.2.4 <br />indicate applicable exception <br />YES <br />C405.2.1 <br />Method of automatic <br />Indicate on plans the method of automatic <br />E Sheets <br />C405.2.2.1 <br />shut-off control <br />shut-off control during unoccupied periods <br />C405.2.1, <br />(occupancy sensor, time switch or digital <br />Exception 3 <br />timer switch) for all lighting zones <br />YES <br />C405.2.1 <br />Occupant sensor <br />Indicate on plans all luminaires that are <br />E Sheets <br />controls <br />controlled by occupant sensor controls; <br />indicate controls are configured to turn <br />luminaires 100% off when the space is <br />unoccupied <br />YES <br />C405.2.1 <br />Occupant sensor <br />Indicate if occupant sensor controls are <br />E Sheets <br />C405.2.1.1 <br />controls <br />configured to be manual on or automatic on to <br />not more than 50% power; indicate spaces <br />eligible for exception that allows automatic on <br />to 100% power <br />Page 1/10 <br />