2018 WSEC Requirements for Commercial Buildings including Group R2 R3 & R4 over 3 stories & all R1 -- Administered by ©2023 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this reportcontact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA <br />C405.2.1.2 <br />Occupant sensor <br />Indicate each aisleway and corridor within a <br />controls - warehouses <br />warehouse space are designated as separate <br />spaces <br />zones that are independently controlled <br />NA <br />Indicate occupant sensors are configured to <br />automatically reduce lighting power by 50% <br />when the zone is unoccupied and 100% off <br />after the zone is unoccupied for over 20 <br />minutes; indicate controls are configured to <br />automatically restore lighting to full power <br />when the zone or space is occupied <br />NA <br />C405.2.1.3 <br />Occupant sensor <br />For open plan office areas larger than 300 sf, <br />controls - open plan <br />indicate general lighting is provided with <br />office areas <br />vacancy controls that reduce lighting power by <br />not less than 80% and are configured to turn <br />luminaires 100% off when the space is <br />unoccupied; indicate that no individual control <br />zone area exceeds 600 sf <br />C405.2.1.4 <br />Occupant sensor <br />Indicate parking garage general lighting is <br />controls - parking <br />provided with vacancy controls that reduce <br />garages <br />lighting power by not less than 30% and are <br />configured to turn luminaires 100% off when <br />no velucles or pedestrians are present, unless <br />eligible for an exception; indicate that no <br />individual control zone area exceeds 3,600 sf <br />i <br />NA <br />C405.2.1.5 <br />Occupant sensor <br />Indicate stairway lighting is provided with <br />controls - enclosed <br />vacancy controls that reduce lighting power by <br />fire -rated stairwells <br />not less than 50% when the stairway in <br />unoccupied <br />YES <br />C405.2.2.1 <br />Automatic time <br />Indicate spaces on plans where time switch <br />E Sheets <br />switch controls <br />controls turn luminaires 100% off during <br />unoccupied hours <br />i <br />YES <br />Indicate spaces on plans where time switch <br />E Sheets <br />controls are configured to turn on lighting to <br />full power versus 50% power <br />YES <br />Indicate locations of override switches on <br />E Sheets <br />plans and the lighting zone(s) served; indicate <br />that the area(s) served by each override switch <br />does not exceeds 5,000 sf <br />NA <br />C405.2.1, <br />Digital timer switch <br />Indicate digital timer switch control includes: <br />Exception 3 <br />manual on/off, time delay, audible and visual <br />indication of impending time-out <br />NA <br />C405.2.4.2 <br />Daylight zones - <br />Indicate primary and secondary sidelit <br />C405.2.4.3 <br />Sidelit and toplit <br />daylight zone floor areas on plans <br />NA <br />Indicate toplit daylight zone floor areas on <br />plans <br />— <br />-- —I <br />---- <br />NA <br />For small vertical fenestration assemblies <br />(rough opening less than 10 percent of <br />primary daylight zone floor area) where <br />daylight responsive controls are not required, <br />provide fenestration area to daylight zone <br />floor area calculation(s) <br />I <br />I <br />Page 2110 <br />