Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group'R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA <br />C405.2.4 <br />Daylight responsive <br />Indicate on plans lighting zone(s) served by <br />controls <br />daylight responsive controls; indicate that the <br />area served by each control device does not <br />exceeds 2,500 sf <br />NA <br />Identify sidelit and toplit daylight zones that <br />are not provided with daylight sensing <br />controls and the exception(s) that apply <br />NA <br />C405.2.4.1.1 <br />Daylight responsive <br />Indicate on plans the lighting load reduction <br />controls <br />method (continuous dimming, or stepped <br />dimming that provides at least two even steps <br />between 0%-100% of rated power) <br />NA <br />C405.2.4.1 <br />Daylight responsive <br />Indicate that daylight sensing controls are <br />controls <br />configured to completely shut off all <br />controlled lights in the lighting zone <br />YES <br />C405.2.5 <br />Additional controls - <br />Identify spaces and lighting fixtures on plans <br />E Sheets <br />Specific application <br />that require specific application lighting <br />lighting controls <br />controls per this section <br />YES <br />C405.2.5, <br />Display and accent <br />Indicate on plans that manual controls are <br />E Sheets <br />Item 1 <br />lighting <br />provided that control display, accent lighting <br />and display case lighting independently from <br />both general area lighting and other lighting <br />applications within the same space <br />YES <br />Indicate manual and automatic (occupant <br />E Sheets <br />sensor or time switch) lighting control <br />methods <br />C405.2.5, <br />Hotel/motel guest <br />Indicate method of automatic control - <br />Item 3 <br />rooms <br />vacancy or captive key control of all installed <br />luminaires mid switched receptacles in guest <br />room <br />NA <br />C405.2.5, <br />Supplemental task <br />Indicate method and location of manual and <br />Item 1 <br />lighting <br />automatic shut-off control (occupant sensor or <br />time switch) for supplemental task lighting, <br />including under -shelf or under -cabinet <br />i <br />lighting <br />NA <br />C405.2.5, <br />Lighting equipment <br />Indicate on plans that lighting equipment for <br />Item 1 <br />for sale or <br />sale or. demonstration are controlled <br />demonstration <br />independently from both general area lighting <br />and other lighting applications within the <br />same space <br />NA <br />Indicate manual and automatic (occupant <br />sensor or time switch) lighting control <br />methods <br />NA <br />C405.2.5, <br />Lighting for non- <br />Identify all eligible non -visual lighting <br />i <br />Item 4 <br />visual applications <br />applications on plans; indicate that the area <br />served by each control device does not <br />exceeds 4,000 sf <br />NA <br />Indicate on plans that non -visual lighting are <br />controlled independently from both general <br />area lighting and other lighting applications <br />within the same space <br />Page 3110 <br />