Laserfiche WebLink
2018 WSEC Requirements for Commercial'Buildings including Group R2 R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this reportcontact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA <br />Indicate method of manual lighting control <br />and applicable automatic lighting control ' <br />I <br />YES <br />C405.2.5, <br />Means of egress <br />Identify on plans egress fixtures that function <br />E Sheets <br />Item 5 <br />lighting <br />as both normal and emergency means of <br />egress illumination <br />—� <br />YES <br />Provide calculation of lighting power density <br />E Sheets <br />of total egress lighting <br />YES <br />If total egress lighting power density is greater <br />E Sheets <br />than 0.02 W/sq. ft., indicate on plans egress <br />fixtures requiring automatic shut-off during <br />unoccupied periods <br />YES <br />Indicate method of automatic shut-off control <br />E Sheets <br />J <br />NA <br />C405.4.1 <br />Lighting control of <br />Indicate that exempt interior lighting <br />C405.4.2 <br />exempt interior <br />equipment and lighting located within spaces <br />lighting <br />that are eligible for a lighting power <br />exemption are controlled independently from <br />non-exempt and general area lighting <br />C405.2.6 <br />Exterior lighting <br />For decorative exterior lighting, indicate on <br />controls <br />plans automatic daylight shut-off controls, or <br />exception taken <br />j <br />For exterior lighting that is not decorative, <br />indicate on plans automatic daylight or time - <br />switch shut-off controls and setback controls; <br />or indicate exception taken <br />For lighting requiring setback controls, <br />include control sequence that reduces lighting <br />power by at least 30% between 12am-6am, or <br />from I hour after closing to I hour before <br />i <br />opening, or based upon motion sensor <br />j <br />For building facade and landscape lighting, <br />indicate control sequence for shut-off control <br />is based on dawn -to -dusk and business <br />opening/closing schedule; indicate whether <br />j <br />automatic or time switch controls will be <br />provided for this function <br />C405.5.2 <br />Lighting control of <br />Indicate that exempt exterior lighting and <br />exempt exterior <br />lighting located within exterior areas/surfaces <br />lighting <br />that eligible for a lighting power exemption <br />are controlled independently from non- <br />exempt exterior lighting <br />i ' <br />C405.5.4 <br />Exterior -as-fired <br />Indicate ignition system is a method other <br />lighting appliances <br />then continuously burning pilot light <br />I —I <br />YES <br />C405.2.7 <br />Area controls - <br />Indicate location(s) of master control <br />E Sheets <br />Master control <br />switch(es) intended to control multiple <br />switches and circuit <br />independent switches; circuit breaker may not <br />power limit <br />be used as a master control switch <br />YES <br />Verify that no 20 amp circuit controlled by a <br />E Sheets <br />single switch or automatic control is loaded <br />beyond 80% <br />ADDITIONAL EFFICIENCY CREDIT - ENHANCED INTERIOR LIGHTING CONTROLS <br />Page 4110 <br />