Zi pperGeo Broadway Everett Expansion <br /> Project No. 2601.01 <br /> Geoprofessional Consultants <br /> July 7, 2022 <br /> Shallow Foundation Depth and Width <br /> For frost protection, we recommend the bottom of all exterior footings bear at least 18 inches below the <br /> lowest adjacent outside grade, whereas the bottoms of interior footings should bear at least 12 inches <br /> below the surrounding slab surface level. We recommend that all continuous wall and isolated column <br /> footings be at least 12 and 24 inches wide, respectively. <br /> Resistance to Lateral Loads <br /> Resistance to lateral loads can be achieved through passive earth pressures on the face of embedded <br /> foundation elements and base friction. For conventional shallow footings located outside of the existing <br /> stormwater vault area, we recommend using an ultimate base friction coefficient and passive earth <br /> resistance values of 0.5 and 450 pcf equivalent fluid pressure, respectively. We recommend that passive <br /> resistance be neglected in the upper 18 inches of embedment. The above values do not include safety <br /> factors.Appropriate safety factors or resistance factors should be used for design. Note the above value <br /> for friction coefficient assumes concrete cast against soil. If option B above is used,the project structural <br /> engineer should determine the friction coefficient for concrete cast against CDF or lean concrete. <br /> For conventional shallow footings located inside the stormwater vault area,the value of available passive <br /> resistance will depend on the distance between the face of footing and face of vault,and depth of footing. <br /> In order to rely on passive earth pressures and for those pressures not to impose load on the existing <br /> stormwater vault, the full passive earth pressure failure surface must be uninterrupted between the face <br /> of footing and the stormwater vault wall. The passive earth pressure failure surface can be assumed to <br /> be a line extending upwards from the bottom edge of the footing at an angle of about 28 degrees. A <br /> graphical depiction of this limiting criteria is provided in Figure 2. If the full passive earth pressure failure <br /> surface cannot be developed, passive earth pressures should be ignored. <br /> Due to their small diameter,the lateral capacity of vertical pin piles should be ignored.Alternatively, piles <br /> battered up to 15 degrees could be considered to reduce overall lateral loads. We recommend battered <br /> piles be used in combination with vertical piles. The lateral capacity of battered piles should be taken as <br /> the horizontal component of the unfactored axial pile load (not the horizontal component of the axial <br /> compressive capacity) provided that the resisting force acts in the opposite direction of lateral loads. Any <br /> remaining lateral load may be resisted by passive earth pressures on the face of foundation elements <br /> embedded at least 1.5 feet below finished grade. Base friction for pile-supported foundations should be <br /> neglected. <br /> On-Grade Concrete Slabs <br /> Subgrade Preparation <br /> Slab subgrades should be prepared in accordance with the Site Preparation section of this report. Prior <br /> to placement of slab reinforcement or form work, slab subgrades should be compacted to a firm and <br /> unyielding condition and to at least 95 percent of the modified proctor (ASTM D1557) maximum dry <br /> density. <br /> 14 <br />