Laserfiche WebLink
2015 Washington State Ener. ode Compliance Forms for Commercial,R2 and R3 ove ones and all R1 -Page 2 of 7 <br /> Mechanical Permit Plans Cr.acklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Concentra Everett Date 1/1/2015 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> C403 2 4 3 Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans,verrfy dampers are Class 1 N/A <br /> dampers motorized,refer to HVAC System Controls for additional requirements <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that N/A <br /> C403 2 4 4 Zone isolation dampers are expected to be occupied non-simultaneously,identify isolation zone areas on plans and <br /> locations of associated isolation dampers in HVAC distribution system,refer to HVAC System <br /> Controls for additional requirements <br /> For cooling systems with humidification equipment that are also required to have air N/A <br /> C403 2 3 4 Humidification economizer,indicate humidifier is adiabatic(direct evaporative or fog atomization),or <br /> exception taken <br /> Additional Efficiency Package Option,More Efficient HVAC Equipment&Fan Performance- <br /> Must comply with all 3 provisions to be eligible <br /> C406.2 1 To comply with additional efficiency package option,calculate the percentage of heating and N/A <br /> C403 2 3 HVAC system selection cooling equipment in the protect(based on output capacity)that do not have a corresponding <br /> WSEC listed efficiency,shall be less than 10%to comply <br /> N/A <br /> C406 2 2 Minimum equipment To comply with additional efficiency package option,indicate that all listed heating and cooling <br /> C403 2 3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br /> C406 2 3 To comply with additional efficiency package option,indicate rated FEG of stand alone fans is N/A <br /> C403.2 11 3 Minimum fan efficiency >_71,indicate these fans are sized so the fan efficiency at design conditions is within 10%of <br /> the maximum total or static efficiency <br /> HVAC System Controls <br /> Indicate locations of thermostatic and humidity control devices and the zones they serve on M111 <br /> plans,including perimeter system zones <br /> N/A <br /> Where adjacent(neighboring)zones are controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or loss),and are connected by permanent <br /> Thermostatic controls openings>10%of either zone sf area,indicate controls configured to prevent adjacent zones <br /> C403 2 4 1 (thermostats and from operating in conflicting modes(one in heat,other in cool),applies to adjacent perimeter <br /> humidistats) zones,adjacent nonpenmeter zones,and adjacent perimeter and nonpenmeter zones <br /> If applying Exception 2 to nonpenmeter zones adjacent to perimeter zones,indicate that N/A <br /> setpoints and deadband settings in these zones are coordinated so cooling in a nonpenmeter <br /> zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br /> perimeter zone temperature in heating <br /> C403 2 4 1 1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and N/A <br /> heat supplemental heating controlled with outdoor lock-out temperature set to 40°F or less <br /> C403 2 4 1 2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that N/A <br /> control both heating and cooling <br /> If separate heating and cooling systems with separate thermostatic control devices are used to N/A <br /> Setpoint overlap restriction serve a zone,indicate locations of both thermostatic control devices and the zone they serve <br /> C403 2 4 1 3 on plans <br /> (thermostats) <br /> Indicate a limit switch,mechanical stop or DDC control with programming to prevent N/A <br /> simultaneous heating and cooling <br /> C403 2 4 2 Indicate zone thermostatic controls configured with required automatic setback and manual N/A <br /> C403 2 4 2 1 Automatic setback and override functions,setback temperatures,and control method(automatic time clock or <br /> C403 2 4 2 2 shutdown programmable controls),note exceptions taken <br /> • <br /> C403 2 4 2 3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served N/A <br /> up to design temperature just prior to scheduled occupancy <br /> C403 2 4 3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment N/A <br /> operation,not including economizer cooling,night flush or IMC required OSA/exhaust <br /> C403 2 4 3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of N/A <br /> dampers power) <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that N/A <br /> C403 2 4 4 Zone isolation controls are expected to be occupied non-simultaneously,indicate controls that allow for independent <br /> space conditioning of isolation zones,or exception taken <br /> C403 2 12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off N/A <br /> heating system when area served is unoccupied <br /> N/A <br /> C403 2 4 5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature <br /> exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40°F <br /> C403 2 4 6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or N/A <br /> controls conditions protect fluid from freezing <br /> Group R1 hotel/motel For hotels and motels with over 50 guest rooms,indicate automatic controls serving guest N/A <br /> C403 2 4 9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at <br /> least 5°F,indicate control method-activated by room entry or occupancy sensor <br />