• <br /> 2015 Washington State Ener. ode Compliance Forms for Commercial,R2 and R3 over ones and all R1-Page 3 of 7 <br /> Mechanical Permit Plans Ci. ..cklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> I Project Title: Concentra Everett Date 1/1/2015 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> N/A <br /> C403 2 4 10 Group R2/R3 dwelling For primary space conditioning system,indicate 5-2 programmable thermostats capable of two <br /> C403 2 4 11 units,Group R2 sleeping setback periods per day,for all thermostats indicate purpose(heating only,cooling only,or <br /> units both),required temperature range and at minimum a 10°F deadband,or exception taken <br /> Indicate method of ventilation air delivery(natural or mechanical)for each zone N/A <br /> If mechanically delivered,indicate that systems are configured to provide not more than 150% N/A <br /> C403 2 6 Ventilation of,but at least the minimum required volume of outdoor air to each zone per IMC,ASHRAE <br /> C403 2 11 4 62 1 or other applicable code(WAC,OSHA,etc),or exception taken <br /> If delivered via natural ventilation,identify required elements per IMC including minimum N/A <br /> openable area to the outdoors or qualifying adjoining spaces <br /> Identify spaces>500 sf with occupant load>25 people/1,000 sf per IMC,for each space N/A <br /> Demand controlled indicate whether it is served by an HVAC system with total design OSA>3,000 cfm,and/or <br /> C403 2.6 2 ventilation the system has airside economizer or automatic modulating OSA damper,indicate OSA <br /> controls are configured to provide demand controlled ventilation or provide supporting <br /> documentation for applied exception <br /> For gyms,classrooms,auditoriums and conference rooms>500 sf,indicate occupancy-based N/A <br /> C403 2 6.3 Occupancy sensors OSA control when space is unoccupied and method(closes OSA damper or shuts-off <br /> equipment),or alternate means provided to automatically reduce OSA when space is partially <br /> occupied <br /> C403 2 6 4 Enclosed loading dock For enclosed loading docks,indicate ventilation/exhaust system method of activation(gas N/A <br /> C403 2 6 4 1 ventilation detection system for CO and NO2,or occupancy sensors),and control method(staged or <br /> modulating) <br /> N/A <br /> C403.2 6 4 Enclosed parking garage For enclosed parking garages,indicate ventilation/exhaust system activated by gas detection <br /> C403 2 6 4 2 ,ventilation system for CO and NO2,and control method(staged or modulating),or exception taken <br /> N/A <br /> Provide calculations that show a balanced accounting of total kitchen exhaust(include all <br /> hoods)with%of supply air,transfer air from adjacent spaces,and make-up air,rf applicable, <br /> C403 2 7 1 Kitchen exhaust hoods indicate that direct make-up air to each hood does not exceed 10%of hood exhaust <br /> For kitchens with total hood exhaust exceeding 2,000 cfm,indicate exhaust air rate per Table N/A <br /> C403 2 7 1 and compliance method(DCV,energy recovery,or transfer air that would <br /> otherwise be exhausted) <br /> N/A <br /> C403 2 7 2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements <br /> Variable flow capacity- For HVAC fan motors>_7 5 hp,indicate method of variable flow control(VSD,or equivalent N/A <br /> C403 2 13 HVAC system fans control method that reduces design air volume by 50%at 1/3 static design pressure),note <br /> exception taken <br /> DX air handler variable For DX air handlers with economizer and cooling capacity z 65,000 Btu/h,indicate number of <br /> cooling stages provided and method(multiple compressors and/or variable speed <br /> C403 3 1 cooling control compressors),indicate minimum displacement(capacity reduction)as%of full load N/A <br /> 1(UnderIntegrated - <br /> Economizer) Indicate control method(cooling capacity controlled in response to space temperature,space <br /> temperature controlled by modulating supply airflow,or both) N/A <br /> For DX air handling units with cooling capacity>_65,000 Btu/h and evaporative and chilled <br /> water air handling units with fan>_0 25 hp,indicate whether system is single zone or multiple <br /> zone and related control method(cooling capacity controlled in response to space <br /> temperature,space temperature is controlled by modulating supply airflow,or both) N/A <br /> For mechanical cooling systems(includes DX and chilled water coils)that control cooling <br /> capacity in response to space temperature-Provide a minimum of two stages of fan control, <br /> C403 2 11 5 Fan airflow control indicate minimum fan speed is<_66%of full speed drawing 5 40%of full speed fan power <br /> during periods of low cooling or ventilation only N/A <br /> For other mechanical cooling systems(includes DX and chilled water coils)that control space <br /> temperature by modulating airflow(in lieu of,or in addition to,controlling capacity in response <br /> to space temperature)-Provide fan controls for modulating supply airflow,indicate minimum <br /> fan speed is 5 50%of full speed drawing 5 30%of full speed fan power during periods of low <br /> cooling or ventilation only,or exception taken N/A <br /> Provide central and zone level DDC controls as required based on system application, <br /> capacity or size thresholds and other qualification per Table C403 2 4 12 1 N/A <br /> C403.2 4 12 'DDC system capabilities - - -- <br /> Identify all DDC system input/output control points,indicate capability for trending and <br /> graphical display N/A <br /> Ducting Systems <br /> C403 2 8 1 Indicate on plans that all ductwork is constructed and sealed per IMC M001 <br /> C403 2 8 3 Duct construction For OSA ductwork,also indicate on plans that ductwork meets air leakage requirements per <br /> C402 5 and vapor retarder requirements per the IBC N/A <br /> C403 2 8 3 Duct pressure classifications Identify location of low,medium and high pressure ductwork on plans M111 <br /> C403 2 8 3 3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans,provide test results to Specificatio <br /> test jurisdiction when completed ns <br />