2 3 4 <br /> TO UTILITY <br /> TRANSFORMER <br /> EXISTING GRADE <br /> /V�/V�/��/V%V�/��/V UNDISTURBED SOIL G P D G RO U P <br /> MAIN BONDING = \ \ \ \ \ \ \ <br /> JUMPER(FACTORY .I z 1- (TYP.) Professional Corporation <br /> PROPOSED MAIN INSTALLED) - 520 sown Win street style2531 <br /> DETECTABLE WARNING TAPE wt,,oN aa311311 <br /> SERVICE N RED WITH BLACK LETTERING 330.572.21M FaX330.572.2101 <br /> EQUIPMENT " VERIFY WITH INDICATING"ELECTRICAL"AND <br /> PROPOSED NEUTRAL I POWER ROUTED ALONG CONDUIT PATH <br /> CONDUCTOR.SEE COMPANY CLEAN GRANULAR BACKFILL. <br /> I O O 0 6"LIFT MAXIMUM,PLATE <br /> FEEDER/CIRCUIT I <br /> n <br /> SCHEDULE I w TAMP(1/2"),95% <br /> j PROPOSED#4/0 AWG Cu p O COMPACTION MINIMUM <br /> TO ADDITIONAL I z 20 <br /> CABINETS I GROUNDING ELECTRODE io Lu 6)4"PVC SCHEDULE 80 CONDUITS, <br /> I CONDUCTOR TO(2)5/8"x8'-0" w 7.5„ 6„ FROM SERVICE UTILITY <br /> I GROUND RODS SPACED @ �� TYP MIN TRANSFORMER TO SERVICE <br /> ANGER <br /> j 6'-0"O.C.MIN. HAND TAMPED ENTRANCE EQUIPMENT.PROVIDE <br /> PROPOSED VERIFY SWEEPING NON-ACUTE ANGLED 5 L n T <br /> • 12"GRANULAR <br /> CHARGING ,:.:6] PROPOSED CABINET EGC.SEE BACKFILL(SAND SEE NOTE 4 BENDS FOR ALL CONDUITS. <br /> CABINET j I I FEEDER/CIRCUIT SCHEDULE BEDDING) <br /> NO SAFE PPE EXISTS i i i NOTES: <br /> ENERGIZED WORK PROHIBITED PROPOSED POST ;III 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF. `p`fi�saioo <br /> FLASH PROTECTION SHOCK PROTECTION EGC.SEE \_fi <br /> FEEDER/CIRCUIT Imyn 2. ANY PAVEMENT DAMAGE DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE <br /> Incident Energy at ism Shock risk when 480 VAC SCHEDULE TO ADDITIONAL CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> Min.Arc Rating: 123.5 cal/cm-2 cover is removed POSTS <br /> Arc Flash Boundary:3271n PROPOSED 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD <br /> Glove Class: 00 Limited Approach 421n CHARGING POST CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESLA CONTACT LISTED ON <br /> DO NOT WORK ON LIVE! SHEET T-1. <br /> Restricted Approach 121, <br /> 4. VERIFY WIDTH OF TRENCH REQUIRED. REFER TO SITE ELECTRICAL DRAWING FOR ROUTING. <br /> Bus:INCOMING SECTION-MAIN Prot:MaxTripTime 02.Os 5. VERIFY ALL REQUIREMENTS WITH POWER COMPANY <br /> INCOMING UTILITY SECTION DETAIL NOT USED N.T.S 6 TYPICAL GROUNDING DIAGRAM N.T.S 4 SECONDARY FEEDERS TRENCH DETAIL N.T.S 1 o a <br /> Z w w <br /> O <br /> WARNING a > > 0000 <br /> EXISTING GRADE Er w w o 0 <br /> A/V�/V�/\��/\��/V�%V��\��\-_ UNDISTURBED SOIL w °' °i z z <br /> -�I �vvvvv � vv III TYP. o o ��- ��- <br /> Arc Flash and Shock Risk I' - ( ) ` a <br /> DETECTABLE WARNING TAPE RED aw w w w r7wi <br /> Appropriate PPE Required N WITH BLACK LETTERING aN w <br /> FLASH PROTECTION SHOCK PROTECTION INDICATING"ELECTRICAL"AND <br /> Incident Energy at is 1n Shock risk when 480 VAC ROUTED ALONG CONDUIT PATH Lu A <br /> Min.Arc Rating: 1.50 cal/cm^2 cover is removed 1"OF GRANULAR z 0 0 _ <br /> Arc Flash Boundary:zt in BACKFILL O a CLEAN GRANULAR BACKFILL.6"LIFT <br /> Glove Class: 00 ( ) > <br /> Limited Approach 42 in BETWEEN MAXIMUM,PLATE TAMP 1/2",95% w < m O o <br /> CONDUITS zLO <br /> OO COMPACTION MINIMUM.PROVIDE <br /> iO SLURRY BACKFILL AS ALTERNATE <br /> Restricted Approach 121, �� N P SC <br /> HAND-TAMPERED CLEAN 6" 6" VERIFY CONDUIT TYPE, JFi w� <br /> Bus:CHARGING CABINETS Prot:600A BREAKER SIZE AND QUANTITY WITH <br /> B GRANULAR BACKFILL W/ S VENOTE 4 FEEDER SCHEDULE <br /> 6"SAND BEDDING. 2 <br /> CHARGING CABINETS PROVIDE SLURRY <br /> BACKFILL AS ALTERNATE <br /> NOTES: <br /> 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF.ALL TRENCHING SHALL ISiEt"' <br /> WARNING BE ACCORDING TO THE LATEST OSHA STANDARDS �70NAL <br /> 09/08/22 <br /> 2. ANY PAVEMENT DAMAGE DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY EXPIRES 02/03/2024 <br /> THE CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> Arc Flash and Shock Risk 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD } <br /> Appropriate PPE Required CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESLA CONTACT LISTED ON <br /> FLASH PROTECTION SHOCK PROTECTION SHEET T-1. <br /> Incident Energy at tom Shock risk when 480 VAC 4. VERIFY WIDTH OF TRENCH REQUIRED. REFER TO SITE ELECTRICAL DRAWING FOR J 00 <br /> Min.Arc Rating: 1.34 cal/cmA2 cover is removed ROUTING. Q z C J <br /> Arc Flash Boundary:is 1n <br /> Glove Class: 00 G 63 <br /> Limited Approach az in DETAIL NOT USED N.T.S 7 DETAIL NOT USED N.T.S 5 TYPICAL TRENCH DETAIL N.T.S 2 Q Q U J <br /> v Restricted Approach 121n I— <br /> Q <br /> LU Cl) <br /> Bus:PANEL'DP2' Prot:100A BREAKER OPTION A" OPTION B* OPTION C* Q H U I_ <br /> UNDISTURBED SOIL LJJ J W Uj <br /> o SUB-PANEL'DP2' DETECTABLE WARNING TAPE EXISTING GRADE (NP) W w W J <br /> U RED WITH BLACK LETTERING <br /> a INDICATING"ELECTRICAL"AND n, �� � w .�� W <br /> 3 ROUTED ALONG CONDUIT PATH i iyT r r i i i i ,r i i r r i i i i TyyT r CLEAN GRANULAR BACKFILL.6" LU <br /> d z_ LIFT <br /> 95%COMPACTION I MINIMUM FOR Ln <br /> w ASPHALT/CONCRETE AREAS. <br /> 80%COMPACTION MINIMUM FOR <br /> { p .l LANDSCAPED AREAS. <br /> 1"OF GRANULAR ." 000 <br /> NOTES' BACKFILL O O O ISSUED FOR: <br /> 3 CBETWEEN <br /> ONDUITS O O 0 ,DODO z rr ^i x �:J ti ny�, PERMIT XXX <br /> a 1. FOR ANY QUESTIONS OR CLARIFICATIONS REGARDING LABELS,CONTACT MIKE GREEN, GPD -Q O g„ (4)DC POST CONDUIT CLUSTERS <br /> 3 GROUP,AT 330-572-2267. OOOO z SE NO E 5 FROM EACH CABINET.REFER TO BID XXX <br /> d A RH060 CLEAN GRANULAR "' FEEDER SCHEDULE FOR CONDUIT CONSTRUCTION XXX <br /> 2. ARC FLASH INCIDENT ENERGY ANALYSIS COMPLETED PER NFPA 70E 2018. BACKFILL.IF HIGHER RHO 6' a^ TYPE,SIZE AND QUANTITY <br /> w VALUES ARE FOUND, SE NO E 5 MIN "CONTRACTOR MAY SELECT RECORD XXX <br /> 3. ARC FLASH CALCULATIONS PER IEEE 1584,2018. PROVIDE SLURRY BACKFILL vERIFv SUITABLE OPTION BASED ON FIELD <br /> (5 RH060)AS ALTERNATE SEE NOTE 4 CONDITIONS AND NOTIFY TESLA <br /> 4. LABELS SHALL BE PRINTED WITH PERMANENT INK ON WEATHERPROOF LABELS WITH SELF OF ANY DISCREPANCIES. INs7ALL MANAGER DESIGNER <br /> 17. STICKING ADHESIVE. NOTES: BRETT JDP <br /> 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF.ALL TRENCHING SHALL BE ACCORDING TO THE LATEST OSHA STANDARDS. COURNOYER <br /> 5. INSTALL LABELS PER NEC SECTION 110.16. 2. ANY PAVEMENT DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> JOB NO. <br /> N n 6. FOR EACH SWITCHGEAR SECTION,CONTRACTOR SHALL PROVIDE(1)APPLICABLE LABEL ON 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESLA CONTACT LISTED ON SHEET T-1. O O 4 . <br /> EXTERIOR DOOR AND(1)APPLICABLE LABEL ON INTERIOR FRONT FACING SECTION. <br /> ry N CONTRACTOR SHALL FIELD VERIFY SPECIFIC LOCATION FOR LABEL PLACEMENT(S). 4. FIELD VERIFY WIDTH OF TRENCH REQUIRED.REFER TO SITE ELECTRICAL DRAWING FOR ROUTING. <br /> O f1 <br /> E 7. CONTRACTOR SHALL PROVIDE LABELS WITH ANY ADDITIONAL INFORMATION AS REQUIRED BY 5. DC POST CONDUIT DUCT BANK DESIGN BY TESLA BASED ON RHO60 SOIL TYPE&BACKFILL.CONTRACTOR SHALL FIELD VERIFY RHO VALUE AND PROVIDE SLURRY BACKFILL(5 RHO60)IF E 3 <br /> z d LOCAL JURISDICTION,STATE AND FEDERAL CODES AND LAWS. VALUES HIGHER THAN RH060 ARE FOUND. <br /> wE <br /> H .T <br /> d ARC FLASH LABELS N .S 9 DETAIL NOT USED N T.S 8 DC POST CONDUIT TRENCH DETAIL N.T.S 3 <br />