Laserfiche WebLink
2 3 4 <br /> TO UTILITY <br /> TRANSFORMER <br /> EXISTING GRADE <br /> UNDISTURBED SOIL G P D G RO U P <br /> MAIN BONDING 11 1 I <br /> A \ \ \ \ \ \ <br /> JUMPER(FACTORY z - (NP.) Professional Corporation <br /> INSTALLED) - 520 somh Main S-L soil,2531 <br /> PROPOSED MAIN DETECTABLE WARNING TAPE M.,off a 311 <br /> SERVICE a RED WITH BLACK LETTERING 33o.5n.zto0 F.330.5n.sm1 <br /> EQUIPMENT _e e VERIFY WITH INDICATING"ELECTRICAL"AND <br /> PROPOSED NEUTRAL i POWER ROUTED ALONG CONDUIT PATH <br /> CONDUCTOR.SEE COMPANY CLEAN GRANULAR BACKFILL. <br /> I O O a 6"LIFT MAXIMUM,PLATE <br /> FEEDER/CIRCUIT I <br /> SCHEDULE I W O O TAMP CT),N MI <br /> j PROPOSED#4/0 AWG Cu p COMPACTION MINIMUM <br /> TO ADDITIONAL I z ' <br /> GROUNDING ELECTRODE io w m� - --(6)4"PVC SCHEDULE 80 CONDUITS, <br /> CABINETS CONDUCTOR TO(2)5/8"x8'-0" w 7.5" 6" <br /> GROUND RODS SPACED @ rn TYP MIN FROM SERVICE UTILITY <br /> TRANSFORMER TO SERVICE <br /> C _ 6'-0"O.C.MIN. HAND TAMPED ENTRANCE EQUIPMENT. PROVIDE T 5 L n <br /> DANGER PROPOSED 12"GRANULAR VERIFY SWEEPING NON-ACUTE ANGLED CHARGING 1 <br /> PROPOSED CABINET EGC.SEE BACKFILL(SAND SEE NOTE 4 BENDS FOR ALL CONDUITS. <br /> CABINET +III FEEDER/CIRCUIT SCHEDULE BEDDING) <br /> NO SAFE PPE EXISTS i i i NOTES: <br /> ENERGIZED WORK PROHIBITED PROPOSED POST I !III 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF. �`ew se aoa <br /> FLASH PROTECTION SHOCK PROTECTION EGC.SEE <br /> FEEDER/CIRCUIT 2. ANY PAVEMENT DAMAGE DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE <br /> Incident Energy at to in Shock risk when 480 VAC SCHEDULE TO ADDITIONAL CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> Min.Arc Rating: 123.5 cal/cm-2 cover is removed POSTS <br /> Arc Flash Boundary:327 in PROPOSED 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD <br /> Glove Class: 00 Limited Approach 421n CHARGING POST CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESLA CONTACT LISTED ON <br /> DO NOT WORK ON LIVE! SHEET T-1. <br /> Restricted Approach 121n <br /> 4. VERIFY WIDTH OF TRENCH REQUIRED.REFER TO SITE ELECTRICAL DRAWING FOR ROUTING. <br /> Bus:INCOMING SECTION-MAIN Prot:MaxTripTinne G2.0s 5. VERIFY ALL REQUIREMENTS WITH POWER COMPANY <br /> INCOMING UTILITY SECTION DETAIL NOT USED N.T.S 6 TYPICAL GROUNDING DIAGRAM N.T.S 4 SECONDARY FEEDERS TRENCH DETAIL N.T.S 1 <br /> Z <br /> O 3 <br /> H w w <br /> EXISTING GRADE K w w <br /> ! WARNIN G //i ii//i//i/�i//i\//\/ W N m <br /> _ \\\\\\\\\\\\\\�\III_ UNDISTURBED SOIL CI O O z z <br /> Arc Flash and Shock Risk I' - (T�P) <br /> 0 o w w <br /> DETECTABLE WARNING TAPE RED <br /> Appropriate PPE Required N WITH BLACK LETTERING N <br /> FLASH PROTECTION SHOCK PROTECTION INDICATING"ELECTRICAL"AND u <br /> Incident Energy at tam Shock risk when 480 VAC ROUTED ALONG CONDUIT PATH H n <br /> Min.Arc Rating: 1.50 cal/cmA2 cover is removed 1"OF GRANULAR �_ /'� o <br /> Arc Flash Boundary:211, BACKFILL S O O CLEAN GRANULAR BACKFILL.6"LIFT o 0 <br /> Glove Class: 00 ( ) > <br /> BETWEEN MAXIMUM,PLATE TAMP 1/2",95% <br /> of <br /> Limited Approach a2 in z w ¢ m O o <br /> O O O COMPACTION MINIMUM.PROVIDE <br /> CONDUITS m * SLURRY BACKFILL AS ALTERNATE <br /> Restricted Approach tz in N P.S <br /> 6" 6 VERIFY CONDUIT TYPE, �'� enx Cy9 <br /> Bus:CHARGING CABINETS Prot:600A BREAKER HAND-TAMPERED CLEAN VERIFY SIZE AND QUANTITY WITH ye <br /> B GRANULAR BACKFILL W/ <br /> 6"SAND BEDDING. SEE NOTE 4 FEEDER SCHEDULE o <br /> CHARGING CABINETS PROVIDE SLURRY <br /> BACKFILL AS ALTERNATE , <br /> SU]9 <br /> NOTES: C)t RF(:/slti0.� <br /> 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF.ALL TRENCHING SHALL FS,sG <br /> BE ACCORDING TO THE LATEST OSHA STANDARDS. NAL 12/16/2021 <br /> F�WARNING 2. ANY PAVEMENT DAMAGE DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY OIMMI 02/03/2022 <br /> THE CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> Arc Flash and Shock Risk 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD } <br /> Appropriate PPE Required CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESLA CONTACT LISTED ON <br /> FLASH PROTECTION SHOCK PROTECTION SHEETT-1. <br /> Incident Energy at is in Shock risk when 4. VERIFY WIDTH OF TRENCH REQUIRED. REFER TO SITE ELECTRICAL DRAWING FOR J 00 <br /> 480 VAC <br /> Min.Arc Rating: 1.34 Cal/CmA2 cover is removed ROUTING. Q z CD J <br /> Arc Flash Boundary:ie in <br /> Glove Class: 00 c 0 CID U) <br /> Limited Approach 421n DETAIL NOT USED N.T.S 7 DETAIL NOT USED N.T.S 5 TYPICAL TRENCH DETAIL N.T.S 2 Q J <br /> vRestricted Approach 12 in <br /> N Bus:PANEL'DP2' Prot:100A BREAKER w <br /> OPTION A* OPTION B* OPTION C* UNDISTURBED SOIL W w U W <br /> SUB-PANEL'DP2' DETECTABLE WARNING TAPE (TYP) W co W J <br /> U RED WITH BLACK LETTERINGLLJ <br /> EXISTING GRADE <br /> a INDICATING"ELECTRICAL"AND /�` iiiN.. � W <br /> 3 ROUTED ALONG CONDUIT PATH i i i �i i i �� i i i NT i CLEAN GRANULAR BACKFILL.6" W W <br /> LIFT MAXIMUM,PLATE TAMP(1/2") U) <br /> o N ' 95%COMPACTION MINIMUM FOR <br /> w' ASPHALT/CONCRETE AREAS. <br /> " r 3yy, "' r1+ .,y �''` r "•^<. 80%COMPACTION MINIMUM FOR <br /> LANDSCAPED AREAS. <br /> 1"OF GRANULAR 0 0 lJ <br /> ry NOTES: BACKFILL ` �Q QQ �� ISSUED FOR: <br /> BETWEEN O O 0 QOQ } w ,,= PERMIT XXX <br /> -30 1. FOR ANY QUESTIONS OR CLARIFICATIONS REGARDING LABELS,CONTACT MIKE GREEN,GPD CONDUITS O Q �w,, i ' <br /> a '3 g. (4)DC POST CONDUIT CLUSTERS BID XXX <br /> 3 GROUP,AT 330-572-2267. • D 0d i z SE NO E 5 FROM EACH CABINET.REFER TO <br /> A RH060 CLEAN GRANULAR -` u, FEEDER SCHEDULE FOR CONDUIT CONSTRUCTION XXX <br /> v 2. ARC FLASH INCIDENT ENERGY ANALYSIS COMPLETED PER NFPA 70E 2018. BACKFILL.IF HIGHER RHO s^ 6" - -^3' TYPE,SIZE AND QUANTITY <br /> w' VALUES ARE FOUND, SE No E 5 MIN "CONTRACTOR MAY SELECT RECORD XXX <br /> 3. ARC FLASH CALCULATIONS PER IEEE 1584,2018. PROVIDE SLURRY BACKFILL VERIFY SUITABLE OPTION BASED ON FIELD <br /> (s RH060)AS ALTERNATE SEE NOTE a CONDITIONS AND NOTIFY TESTA <br /> 4. LABELS SHALL BE PRINTED WITH PERMANENT INK ON WEATHERPROOF LABELS WITH SELF OF ANY DISCREPANCIES. INSTALL MnrvnOER DESIGNER <br /> m STICKING ADHESIVE. NOTES: BRETT 'DP <br /> 1. ANY EXCAVATION LEFT OPEN SHOULD BE SECURELY FENCED OFF.ALL TRENCHING SHALL BE ACCORDING TO THE LATEST OSHA STANDARDS. COURNOYER <br /> 'rn 5. INSTALL LABELS PER NEC SECTION 110.16. 2. ANY PAVEMENT DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER. <br /> a� JOB NO. <br /> o< 6. FOR EACH SWITCHGEAR SECTION,CONTRACTOR SHALL PROVIDE(1)APPLICABLE LABEL ON 3. CONTRACTOR SHALL INSTALL CONDUITS BELOW LOCAL FROST LINE.SHOULD FIELD CONDITIONS VARY,CONTRACTOR SHALL COORDINATE WITH TESTA CONTACT LISTED ON SHEET T-1. O O 4 . <br /> EXTERIOR DOOR AND(1)APPLICABLE LABEL ON INTERIOR FRONT FACING SECTION. <br /> CONTRACTOR SHALL FIELD VERIFY SPECIFIC LOCATION FOR LABEL PLACEMENT(S). 4. FIELD VERIFY WIDTH OF TRENCH REQUIRED. REFER TO SITE ELECTRICAL DRAWING FOR ROUTING. <br /> O� <br /> 7. CONTRACTOR SHALL PROVIDE LABELS WITH ANY ADDITIONAL INFORMATION AS REQUIRED BY 5. DC POST CONDUIT DUCT BANK DESIGN BY TESLA BASED ON RH060 SOIL TYPE&BACKFILL.CONTRACTOR SHALL FIELD VERIFY RHO VALUE AND PROVIDE SLURRY BACKFILL is RH060)IF E 3 <br /> z LOCAL JURISDICTION,STATE AND FEDERAL CODES AND LAWS. VALUES HIGHER THAN RH060 ARE FOUND. <br /> c <br /> m ARC FLASH LABELS N.T.S 1 9 DETAIL NOT USED N.T.S 8 DC POST CONDUIT TRENCH DETAIL N.T.S 3 <br /> o`o <br />