Honeywell <br /> HPFF8, HPFF8CM, <br /> HPFF8E, HPFF8CME <br /> NAC Expander/Power Supply <br /> Description <br /> The Honeywell HPFF8(E) and HPFF8CM(E) are Notification <br /> Appliance Circuit(NAC)Expander Power Supplies designed to <br /> extend the power capabilities of existing NACs and provide <br /> power for auxiliary devices. The HPFF8 and HPFF8CM con- <br /> nects to any 12 or 24V Fire Alarm Control Panel (FACP) or <br /> operates stand-alone. <br /> They provide regulated and filtered 24VDC power to four <br /> NAC's and an auxiliary output. The NAC outputs are rated at HPFF8 <br /> 3.0 amps each and the auxiliary output is rated at 2.0 amps <br /> (this output is continuously supplied, even in alarm,and there- a <br /> fore must be taken into account for power supply loading and <br /> battery size calculations).The combined output cannot exceed <br /> 8.0 amps. <br /> The HPFF8 and HPFF8CM provide independent output circuit 0' <br /> supervision so in the event of a NAC fault they can notify the <br /> attached FACP. In addition they have a trouble memory <br /> fea- r <br /> ture that displays past troubles(by NAC)for rapid diagnostics. 01 <br /> Synchronization is built in for five appliance brands. <br /> The HPFF8 and HPFF8CM have two fully independent super- <br /> vised initiating circuits that can be used for synchronized <br /> strobes and coded horns. Their NAC outputs may be config- <br /> ured as any of the following: \ HPFF8CM <br /> • four Class B(Style Y) <br /> • two Class A(Style Z) —Two Class B&one Class A. <br /> • two Class B and one Class A —Two Class A(Style Z). <br /> • four Class A with the optional HPP31076 Class A adapter —Four Class A(requires the HPP31076 Class A adapter). <br /> These power supplies contain an internal Battery charger Four field-programmable operational modes: <br /> capable of charging up to 26.0 amp-hour(AH)batteries. <br /> —Pass-through. <br /> The HPFF8 is mounted in a lockable wall cabinet that can —Temporal generator. <br /> accommodate up to two 18AH batteries. The HPFF8CM is <br /> designed to mount in Honeywell's large equipment enclosure —Sync generator. <br /> (EQBB-D4; order separately). Up to four HPFF8CM supplies —Pass-through Filtered. <br /> can be mounted in a D-sized EQ cabinet. Each HPFF8CM can Temporal coding and sync protocols compatible with the fol- <br /> accommodate two 12AH batteries. lowing notification appliance brands: <br /> One of the most challenging aspects of a retrofit application is —System Sensor. <br /> locating the existing End-of-Line(EOL) resistor. In these appli- —Faraday. <br /> cations that have EOL values other than the 3.9k normally <br /> used with the HPFF8, a single resistor matching the existing —Amseco. <br /> EOL can be used as a reference for all the outputs. This fea- —Cooper-Wheelock. <br /> ture speeds installation and system checkout because the —Gentex. <br /> actual EOL does not need to be located and changed in the Protocol pass-through for synchronizing large systems. <br /> circuit.The reference resistor must be within the range of 1.9k <br /> to 25k. Two fully independent supervised input/output control circuits. <br /> NOTE: 4 separate programming resistors for the HPFF8 are pro- Redundant activation operation for survivability. <br /> vided in the hardware kit shipped with each HPFF8(E) and Supports FACP's Selectable Silence ability. <br /> HPFF8CM(E). They are 3.9K(5 of these are provided, need only 2.0 amp auxiliary continuously supplied output. <br /> 1 for programming),2.2K(1 each),4.7K(1 each)and 1 OK(1 each) Eight status LEDs. <br /> Features • Supervised AC input, battery voltage,auxiliary output,char- <br /> ger,and earth ground faults. <br /> • Listed to UL Standard 864,9th edition. • Trouble indication for supervision of the following: <br /> • Four (4) power limited supervised notification application —NAC circuits. <br /> circuits (NAC's) capable of supplying +24VDC at 3.0 amp <br /> maximum each. —Auxiliary output. <br /> • NAC output circuits may be configured as any of the follow- —AC input. <br /> ing: —Battery charger voltage. <br /> —Four Class B(Style Y). —Earth ground faults. <br /> • Optional two-hour delay for AC loss. <br />