My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY 301, 306 TERRA STAFFING 2025-07-31
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
TERRA STAFFING
>
1000 SE EVERETT MALL WAY 301, 306 TERRA STAFFING 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 12:02:41 PM
Creation date
4/24/2025 11:39:32 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Unit
301, 306
Tenant Name
TERRA STAFFING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Separate Trouble and AC Fail Form-C relay contacts. HPFF8E:240VAC/5OHz version of HPFF8. <br /> • The Trouble Form-C relay contacts selectable for immediate HPFF8CM: 8.OA fire rated power supply (chassis mounted). <br /> or a 2 hour delay with AC failure. Unit includes mounting hardware, battery cable and instruc- <br /> • 26 AH battery charger capability: tions for installation in large equipment enclosure. 120VAC/ <br /> -HPFF8(E)supports two 12V 18AH batteries 60Hz. <br /> -HPFF8CM(E)supports two 12V 12AH batteries per unit. HPFF8CME:240VAC/5OHz version of HPFF8CM. <br /> • NAC Overload protection and indication. HPP31076: Class A (Style Z) NAC Adaptor. Increase Class A <br /> • Provision for mounting single or 6 circuit addressable con- circuits from 2 to 4. <br /> trol or relay modules inside the enclosure. (Use mounting Large Equipment Enclosure: EQ series cabinet for mounting <br /> kit PN 90475.) HPFF8CM power supplies consists of a backbox (EQBB-D4) <br /> and a locking door(EQDR-D4 or FCI-VDR-D4B). Order sepa- <br /> Specifications rately. <br /> Primary Input Power: 120VAC, 60Hz, 3.6A standard; CMF-300-6: Six-circuit supervised addressable control mod- <br /> 240VAC,50Hz, 1.5A on units with E suffix. ule activated through FACP programming on a select basis to <br /> Secondary Power:24 volt operation:two 7-26 AH batteries. control power supply activation or output. <br /> CMF-300: Supervised addressable control module activated <br /> Battery Charging Capacity: Up to 26 AH batteries. through FACP programming to activate power supply. <br /> HPFF8 Cabinet: Holds up to two 18AH batteries. BAT-12120: Battery, 12 volt, 12.0 AH (two required). <br /> HPFF8CM: Holds up to two 12AH batteries. BAT-1270: Battery, 12 volt,7.0 AH (two required). <br /> Total Output Current: 8.OA max. 90474: Mounting kit; required to attach an addressable mod- <br /> Standby Current:0.075 A. ule onto the control circuit board (included with supply). <br /> Auxiliary Power Output:2.OA under all conditions. <br /> NAC Output Ratings: 24VDC fully regulated, 3.OA max per Listings and Approvals <br /> circuit(8.OA total). Listings and approvals below apply to all. In some cases,cer- <br /> End-of-Line Resistor Range: 1.91K to 25k ohm,1/2 watt. Prod- tain modules may not be listed by certain approval agencies, <br /> uct ships with 4 separate programming resistors. They are or listing may be in process. Listed under UL 864 9th Edition. <br /> 3.91K(5 each-only need one for programming),2.21K(1 each), • UL Listed:S24562 <br /> 4.71K(1 each)and 10K(1 each) • FM Approved <br /> Common Trouble:2.OA at 30VDC. • CSFM: 7315-1637:0102 <br /> Relay Fail Relay:2.OA at 30VDC. • NYFD:COA#6032 <br /> Input Control Circuits: compatible with 12 and 24 VDC con- <br /> trol panel NACs. <br /> Input Control Current (alarm): 5.68 mA @ 12 VDC, 12.28 <br /> mA @ 24 VDC. <br /> Temperature Rating:32°F to 120°F(0°C to 49°C). <br /> Relative Humidity: 10%to 93%non-condensing. <br /> Cabinet Dimensions: <br /> • HPFF8 Cabinet: 16.65" W x 19.0" H x 5.2" D (42.29 W x <br /> 48.26 H 13.23 D cm) <br /> • Large equipment enclosure(EQBB-D4): 24"W x 45.9" H <br /> x 5.15" D(60.96 W x 116.52 H x 13.1 D cm) <br /> Product Line Information <br /> HPFF8: 8.OA fire rated power supply. Unit includes red enclo- <br /> sure,battery cable and installation instructions. 120VAC/6OHz. <br /> This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific <br /> applications or anticipate all requirements.All specifications are subject to change without notice. <br /> System Sensor@ is a registered trademark of Honeywell International Inc. <br /> 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. <br /> Automation and Control Solutions Honeywell <br /> Honeywell <br /> 12 Clintonville Road 1(877) HPP-POWR <br /> Northford, CT 06472-1610 hpp.techserv@honeywell.com <br /> www.honeywellpower.com <br /> DH-60541:C1 <br /> Augu <br /> 010 <br /> Made i the <br /> Made n the U.S.A. <br /> @ U.S.Registered Trademark IVO 9001 <br /> ©2010 Honeywell International Inc. 011�11M�IMEMAI�F 1I 111 <br /> Page 2 of 2 OVALITY SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.