Laserfiche WebLink
• Separate Trouble and AC Fail Form-C relay contacts. HPFF8E:240VAC/5OHz version of HPFF8. <br /> • The Trouble Form-C relay contacts selectable for immediate HPFF8CM: 8.OA fire rated power supply (chassis mounted). <br /> or a 2 hour delay with AC failure. Unit includes mounting hardware, battery cable and instruc- <br /> • 26 AH battery charger capability: tions for installation in large equipment enclosure. 120VAC/ <br /> -HPFF8(E)supports two 12V 18AH batteries 60Hz. <br /> -HPFF8CM(E)supports two 12V 12AH batteries per unit. HPFF8CME:240VAC/5OHz version of HPFF8CM. <br /> • NAC Overload protection and indication. HPP31076: Class A (Style Z) NAC Adaptor. Increase Class A <br /> • Provision for mounting single or 6 circuit addressable con- circuits from 2 to 4. <br /> trol or relay modules inside the enclosure. (Use mounting Large Equipment Enclosure: EQ series cabinet for mounting <br /> kit PN 90475.) HPFF8CM power supplies consists of a backbox (EQBB-D4) <br /> and a locking door(EQDR-D4 or FCI-VDR-D4B). Order sepa- <br /> Specifications rately. <br /> Primary Input Power: 120VAC, 60Hz, 3.6A standard; CMF-300-6: Six-circuit supervised addressable control mod- <br /> 240VAC,50Hz, 1.5A on units with E suffix. ule activated through FACP programming on a select basis to <br /> Secondary Power:24 volt operation:two 7-26 AH batteries. control power supply activation or output. <br /> CMF-300: Supervised addressable control module activated <br /> Battery Charging Capacity: Up to 26 AH batteries. through FACP programming to activate power supply. <br /> HPFF8 Cabinet: Holds up to two 18AH batteries. BAT-12120: Battery, 12 volt, 12.0 AH (two required). <br /> HPFF8CM: Holds up to two 12AH batteries. BAT-1270: Battery, 12 volt,7.0 AH (two required). <br /> Total Output Current: 8.OA max. 90474: Mounting kit; required to attach an addressable mod- <br /> Standby Current:0.075 A. ule onto the control circuit board (included with supply). <br /> Auxiliary Power Output:2.OA under all conditions. <br /> NAC Output Ratings: 24VDC fully regulated, 3.OA max per Listings and Approvals <br /> circuit(8.OA total). Listings and approvals below apply to all. In some cases,cer- <br /> End-of-Line Resistor Range: 1.91K to 25k ohm,1/2 watt. Prod- tain modules may not be listed by certain approval agencies, <br /> uct ships with 4 separate programming resistors. They are or listing may be in process. Listed under UL 864 9th Edition. <br /> 3.91K(5 each-only need one for programming),2.21K(1 each), • UL Listed:S24562 <br /> 4.71K(1 each)and 10K(1 each) • FM Approved <br /> Common Trouble:2.OA at 30VDC. • CSFM: 7315-1637:0102 <br /> Relay Fail Relay:2.OA at 30VDC. • NYFD:COA#6032 <br /> Input Control Circuits: compatible with 12 and 24 VDC con- <br /> trol panel NACs. <br /> Input Control Current (alarm): 5.68 mA @ 12 VDC, 12.28 <br /> mA @ 24 VDC. <br /> Temperature Rating:32°F to 120°F(0°C to 49°C). <br /> Relative Humidity: 10%to 93%non-condensing. <br /> Cabinet Dimensions: <br /> • HPFF8 Cabinet: 16.65" W x 19.0" H x 5.2" D (42.29 W x <br /> 48.26 H 13.23 D cm) <br /> • Large equipment enclosure(EQBB-D4): 24"W x 45.9" H <br /> x 5.15" D(60.96 W x 116.52 H x 13.1 D cm) <br /> Product Line Information <br /> HPFF8: 8.OA fire rated power supply. Unit includes red enclo- <br /> sure,battery cable and installation instructions. 120VAC/6OHz. <br /> This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific <br /> applications or anticipate all requirements.All specifications are subject to change without notice. <br /> System Sensor@ is a registered trademark of Honeywell International Inc. <br /> 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. <br /> Automation and Control Solutions Honeywell <br /> Honeywell <br /> 12 Clintonville Road 1(877) HPP-POWR <br /> Northford, CT 06472-1610 hpp.techserv@honeywell.com <br /> www.honeywellpower.com <br /> DH-60541:C1 <br /> Augu <br /> 010 <br /> Made i the <br /> Made n the U.S.A. <br /> @ U.S.Registered Trademark IVO 9001 <br /> ©2010 Honeywell International Inc. 011�11M�IMEMAI�F 1I 111 <br /> Page 2 of 2 OVALITY SYSTEMS <br />