My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY TRADER JOES 2025-08-07
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
1302 SE EVERETT MALL WAY TRADER JOES 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 11:40:35 AM
Creation date
4/24/2025 2:10:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
TRADER JOES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
526
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aff• • Powered by Experience. Driven by Excellence." <br />Ot NFLST <br />A New Fire Alarm System for: <br />AT HOME # 334 <br />1302 SE Everett Mall Way <br />Everett, WA <br />System/Installation Narrative: <br />This project is for a Fire Alarm System to be installed in a retail space. It is an `S/B/M' Occupancy type. <br />The space is approximately 86'000ft2. The building is fully sprinklered per NFPA13. The U.L. listed, <br />addressable, manual and automatic fire alarm system will meet the requirements of 2019 OSSC, OFSC, <br />2017 NEC, all local and adopted Building and Fire codes, including all published, adopted amendments. <br />Installation standards will adhere to NFPA72, 2016 edition. <br />The system design is by Mike Mahoney, CFPS, SET, (NICET level IV), Senior Designer for ADT, LLC <br />Security Services. Email: mmahoney(a,adt.com , Ph. direct line: 407-551-8131 <br />➢ The Fire Alarm System will consist of: <br />o Firelite ES 20OX <br />0 1 remote annunciators (Main entry) <br />o Sprinkler Water Flow, Tamper Switch monitoring. <br />o Manual Pull Station <br />o Smoke Detector installed above the FACP <br />o Notification devices throughout space. <br />o HVAC Duct Smoke Monitoring <br />➢ The Fire Alarm System, Notification (NAC) circuits, shall be Class `B' wired and the initiating <br />(SLC) circuit shall be Class `A' wired. All wiring will be supervised. <br />➢ The fire alarm system will be monitored by a U.L. Listed Central Station for Remote System Type <br />monitoring. No Runner Service. U.L. Certificate enclosed. <br />➢ Off Premise notification shall be accomplished by Cellular back-up communication methods. All <br />NFPA 72, 2019 Edition, Ch.26 Criteria has been met. <br />➢ Tamper Switches as a supervisory signal. Water Flow Switches, Manual Pull Stations, and the Smoke <br />Detector will activate all ADA compliant, ADAAG, 4.28.1, Horn/Strobes. <br />➢ All Horn/Strobe and Strobe appliances will be synchronized and installed using NFPA72, for room and <br />hallway/corridor spacing for ceiling and/or wall mounted appliances. All Horns will be set to high <br />volume levels and shall produce a synchronized temporal tone. <br />AT Home # 334 <br />8-18-2022 <br />
The URL can be used to link to this page
Your browser does not support the video tag.