DC-2 DC-2 <br />Date: 5/29/2020 <br />Made By: SGT <br />Project: Four Corners <br />Description: Dead Loads <br />Roof Assembl <br />Dead Load <br />Waterproofing ............................. <br />2.0 psf <br />112" Plywood Sheathing ................ <br />1.7 psf <br />Wood Trusses at 24" o.c................ <br />4.0 psf <br />Insulation .................................... <br />1.5 psf <br />(2) Layers of 518" GWB.................. <br />5.6 psf <br />Miscellaneous ........................... <br />1.0 psf <br />Total .......................................... <br />15.8 psf Use DL = 16.0 psf <br />Low Roof Assembly <br />Dead Load: <br />Waterproofing ............................. <br />2.0 psf <br />2x T&G Decking .......................... <br />3.9 psf <br />4x8 at 48" o. c................................ <br />1.4 psf <br />Insulation.................................... <br />1.5 psf <br />(2) Layers of 518" GWB.................. <br />5.6 psf <br />Miscellaneous ........................... <br />1.0 psf <br />Total .......................................... <br />15.4 psf Use DL = 16.0 psf <br />Floor Assembl <br />Dead Load: <br />Flooring.................................... <br />1 " Gyp -Crete ................................. <br />314" T & G Plywood ....................... <br />TJI-110 at 16" ox.................... <br />(2) Layers of 518" GWB.................. <br />Miscellaneous ........................... <br />Total........................................ <br />Corridor Floor Assembl <br />Dead Load: <br />2.0 psf <br />9.2 psf <br />2.5 psf <br />1.9 psf <br />5.0 psf <br />1.5 psf <br />22.1 psf Use DL = 25.0 psf <br />Flooring ......................................... 2.0 psf <br />1 " Gyp -Crete ................................. 8.7 psf <br />314" T & G Plywood ....................... 2.5 psf <br />2x8 at 16" o. c................................ 2.0 psf <br />(2) Layers of 518" GWB.................. 5.0 psf <br />Miscellaneous ............................... 1.5 psf <br />Total .............................................. 21.7 psf Use DL = 25.0 psf <br />Balcony Deck Assembly <br />Dead Load: <br />Flooring ......................................... <br />2.0 psf <br />Single -ply waterproof membrane... <br />1.0 psf <br />314" T & G Plywood ....................... <br />2.5 psf <br />2x8 at16"o.c........................... <br />2.0 psf <br />Insulation .................................. <br />1.0 psf <br />Siding ............................................ <br />2.3 psf <br />Miscellaneous ............................... <br />1.5 psf <br />Total .............................................. <br />12.3 psf Use DL = 15.0 psf <br />KW <br />