Laserfiche WebLink
DC-3 DC-3 <br />Date: 5/29/2020 <br />Made By: SGT <br />Project: Four Corners <br />Description: Dead Loads <br />Exterior Wall Assembl <br />Dead Load <br />2x6at16"o.c.............................. <br />1.7 psf <br />Insulation .................................. <br />1.0 psf <br />15132" Plywood Sheathing ............. <br />1.7 psf <br />(1) Layers of 518" GWB.................. <br />2.5 psf <br />Fiber Cement Siding ..................... <br />1.5 psf <br />Miscellaneous ............................... <br />0.5 psf <br />Total .......................................... <br />8.9 psf <br />Use DL = 10.0 psf <br />Party Wall AssemblV <br />Dead Load: <br />(2) Layers of 518" GWB ................. <br />5.0 psf <br />(2) walls, 2x4 at 16" o.c............... <br />2.4 psf <br />15132" Plywood Sheathing ............. <br />1.7 psf <br />Insulation ....................................... <br />0.5 psf <br />Miscellaneous ............................... <br />1.0 psf <br />Total ............................................. <br />10.6 psf <br />Use DL = 11.0 psf <br />Corridor Wall Assembly <br />Dead Load: <br />(2) Layers of 518" GWB ................. <br />5.0 psf <br />2x6 at 12" o.c.............................. <br />2.3 psf <br />15132" Plywood Sheathing ............. <br />1.7 psf <br />Insulation ....................................... <br />0.5 psf <br />Miscellaneous ............................... <br />1.0 psf <br />Total ............................................. <br />10.5 psf <br />Use DL = 11.0 psf <br />Interior Wall Assembly <br />Dead Load: <br />(2) Layers of 518" GWB ................. <br />5.0 psf <br />2x4 at 16"o.c.............................. <br />1.2 psf <br />Insulation ....................................... <br />0.5 psf <br />Miscellaneous ............................... <br />0.5 psf <br />Total ............................................. <br />7.2 psf <br />Use DL = 8.0 psf <br />DCG <br />