My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY MOCHINUT 2025-08-06
>
Address Records
>
EVERGREEN WAY
>
8417
>
MOCHINUT
>
8417 EVERGREEN WAY MOCHINUT 2025-08-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 9:27:11 AM
Creation date
4/29/2025 11:40:41 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Tenant Name
MOCHINUT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
@FAjVE:[A <br />D E S I G N S T U D I O <br />NOTE: MUA INTAKE SHALL BE 10' MIN. <br />FROM ANY HAZARDOUS OR NOXIOUS <br />CONTAMINANT SOURCE. <br />16"X16" OR EQUIVALENT AREA MAKE UP AIR DUCT. <br />24 GA. MIN. GALV. METAL, ALL JOINT SEALED <br />R-8 INSULATION ON MUA SUPPLY <br />DUCT PER WSEC C403.10.1.2. <br />ALL AROUND CONTINUOUS TIGHT WELDED <br />BETWEEN DUCT AND HOOD SYSTEM <br />HOOD BACK WALL HANGER (SEE TYP. <br />DETAIL #1.1 FOR THE CONNECTION) <br />22 GA. S.S. OVER NON—COMBUSTIBLE <br />WALL AS FLASHING 18" MIN. OVER <br />EXHAUST HOOD TOP AND SIDE EDGES. <br />5/8" TYPE "X" FIRE RATED SHEET ROCK <br />NEW INTERIOR METAL STUD WITH <br />NO COMBUSTIBLES IN WALL. <br />NO PLASTIC PIPING AND WIRING. <br />10' MIN. TO ANY AIR INTAKE AND PROPERTY LINE IN ANY <br />DIRECTION; 10'MIN. FROM SAME OR ADJACENT BUILDING. F <br />nnlnllnnl Inn i ni nil <br />EXHAUST OUTLET DISCHARGE SHALL <br />NOT BE LESS THAN 40 INCHES ABOVE <br />THE ROOF SURFACE PER IMC 506.13.1 <br />EXHAUST FAN SHALL BE HINGED AND <br />SUPPLIED WITH A FLEXIBLE <br />WATERPROOF ELECTRICAL CABLE TYP. <br />4X6 BLOCKING W/ <br />HU46 EACH END TYP. <br />EXISTING ROOF LEVEL <br />GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' <br />& EACH TURN) OPENING 12"X12" MINIMUM <br />16"X16" OR EQUIVALENT SECTION AREA. 16 GA. <br />GALV. LIQUID TIGHT WELDED EXHAUST DUCT. <br />FIREWRAP SHALL BE PROVIDED FROM THE POINT OF <br />CEILING/WALL PENETRATION (WHERE IT BECOMES <br />CONCEALED) TO THE OUTLET TERMINAL, PER IMC 506.3.11. <br />NON-COMBUSTIBLE SUSPENDED CEILING <br />HOOD SHALL BE INSTALLED WITH A CLEARANCE <br />TO COMBUSTIBLES OF NOT LESS THAN 18". <br />NOTE. <br />- SEE HOOD SPEC SHEET ON PAGE MK6. <br />- SEE FIRE WRAP SPEC SHEET ON PAGE MK7. <br />- SEE EXHAUST FAN UNIT SPEC SHEET ON PAGE MK8. <br />- SEE MAKE UP AIR UNIT SPEC SHEET ON PAGE MK8. <br />B TYPE I HOOD SECTION 8'-011 (KH-1 <br />SCALE : 1/2" = V-0" <br />PROPOSED T-BAR CEILING <br />8'-0" A.F.F. <br />FLOOR FINISH <br />0'-0" A.F.F. <br />1.1 WALL MOUNTED HOOD SUPPORT DETAILS <br />3" NO.10 METAL FASTENERS BETWEEN <br />WALL STUD & SUPPORT BRACKET <br />16 GA. GALVANIZE SUPPORT BRACKET <br />(B) 1.5" METAL FASTENERS BETWEEN <br />HOOD & SUPPORT BRACKET <br />(A) 2.5" METAL FASTENERS BETWEEN <br />S/S WALL & WALL FRAME <br />A <br />3" STAND OFF S/S FLASHING <br />2-1/2" LO ROOT LUBRICIZED <br />ROUND WASHER RECEX SCREW <br />MAN UFACTURER:WESTERN STATES <br />FASTENING SYSTEMS <br />PART #: 50943 No. 14 <br />NON-COMBUSTIBLE <br />1.5" HEX. WASHER <br />SELF DRILL SCREWS <br />16 GA. GALVANIZE <br />SUPPORT BRACKET <br />SEE DETAIL ON PAGE MK3 <br />THREADED STEEL ROD <br />EXHAUST SECTION <br />BRACKET WELDED <br />ONTO HOOD <br />18 GA. STAINLESS STEEL <br />TYPE I GREASE HOOD <br />1.2 FIREMASTER GREASE DUCT SYSTEM: <br />2 HOUR SHAFT ALTERNATIVE & ZERO <br />CLEARANCE TO COMBUSTIBLE CONSTRUCTION <br />1 <br />2 LAYER FIRE MASTER DUCT WRAP <br />2 <br />FILAMENT TAPE <br />3 <br />BANDING <br />4 <br />3" PERIMETER OVERLAP <br />5 <br />3" LONGITUDINAL OVERLAP <br />6 <br />1/2" DIAMETER HANGER ROD <br />7 <br />1-1/2" x 1-1/2" x 1/8" ANGLE <br />NOTE: <br />1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE CONNECTED BY AN ELECTRICAL INTERLOCKING <br />SWITCH FOR SAME TIME OPERATION <br />2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL BE AS SPECIFIED OR EQUAL. <br />3. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE COOKING AREA. <br />4. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL GREASE TIGHT WELD. <br />5. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF. <br />6. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR SHALL BE NO LESS THAN 101 <br />. <br />7. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPARATE PERMIT. <br />BRACKET WELDED <br />ONTO HOOD <br />MAKE UP AIR SECTION <br />9031 21 ST AVE SW <br />SEATTLE, WA 98106 <br />TEL. 206.322.4323 <br />FAX. 206.322.9177 <br />E-MAIL:INFO@CATCHSTUDIO.COM <br />WWW.CATCHSTUDIO.COM <br />PROJECT TITLE: <br />MOCHINUT <br />EVERETT <br />8417 EVERGREEN WAY <br />EVERETT, WA 98208 <br />SHEET TITLE <br />TYPE I HOOD SECTION <br />PERMIT: <br />DATE: <br />CATCH DESIGN STUDIO <br />DRAWN: NOS NARIN <br />SCALE: AS NOTED <br />NATIVE FILE: <br />DATE: 01/05/2024 <br />SHEET# <br />MK5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.