Laserfiche WebLink
2 3 4 5 <br /> SHEET NOTES <br /> 1. COORDINATE INSTALLATION OF ALL CONDUIT,CABLING, <br /> AND OTHER COMPONENTS WITH ARCHITECT,OWNER& <br /> PUD PRIOR TO ROUGH-IN. <br /> 2. PROVIDE GUYING/BRACING FOR PORTABLE SERVICE • <br /> YKEMAN <br /> MASTS ATTACHED TO PORTABLE ROOF STRUCTURE. <br /> COORDINATE BRACING REQUIREMENTS WITH SNOPUD ARCHITECTURE + DESIGN <br /> b OVERHEAD SERVICE GUIDELINES PRIOR TO <br /> _ _ _ D INSTALLATION.INSTALL BRACING ANCHORS BELOW <br /> D b - - - - - (NOT THROUGH)PORTABLE ROOFING SHINGLES TO D <br /> ENSURE WATER PROOFING OF ROOF IS MAINTAINED. <br /> n <br /> 3. EXPOSED CONDUIT ON EXTERIOR OF BUILDINGS BELOW <br /> ANCHOR ML -10'-0"AEG SHALL BE RIGID METALLIC CONDUIT.PVC <br /> MESSENGER CONDUIT CONCEALED WITHIN SKIRT SPACE SHALL BE <br /> TO BUILDING <br /> ALLOWED. <br /> - - _ AERIAL CABLING <br /> - TO POLE 4. WHERE BUILDING WALLS ARE PENETRATED TO PROVIDE <br /> © ROUTING AS INDICATED,SEAL PENETRATIONS WITH H A R G I S <br /> _(1)1"C&(1)2"C WITH APPROVED FIRE/WEATHER PROOFING MATERIALS. <br /> not MIN.reaae,:w�fiW,seatble,wx aeioi <br /> IL <br /> WEATHERHEAD _ I 5. EXISTING FIRE ALARM PANEL IS A NOTIFIER SYSTEM -all 206ACa.{Ke hn..bh <br /> -it BOX I 5000 MODEL AND IS LOCATED IN ADMIN AREA. <br /> (1)1"C-FIRE ALARM _- 6. FIRE ALARM DRAWINGS HAVE BEEN SUBMITTED TO AHJ <br /> (1)2"C-TELECOM/SECURITY FOR REVIEW AND APPROVAL BASED ON DEVICE • <br /> mom <br /> LAYOUTS SHOWN ON THESE DRAWINGS.CONTRACTOR <br /> - - IS RESPONSIBLE FOR PROVIDING COMPLETE FIRE M I <br /> 18"X18"X6"PULL BOX ALARM SYSTEM INCLUDING ANY ADDITIONAL DEVICES <br /> (E)MAIN INTRUSION _ REQUIRED BASED ON ONGOING REVIEW AND PENDING <br /> oil <br /> _ APPROVAL.COORDINATE FIRE ALARM WORK WITH <br /> DETECTION PANEL':- alp <br /> CONVERGINT FIRE AND SECURITY.POINT OF CONTACT <br /> ROUTE UNDERIS:CURTIS NASATKA,425-902-2517, <br /> =_ ROOF OVER 1- CURTIS.NASATKA@CONVERGINT.COM <br /> `-'_. PROVIDE _ -_ <br /> '��ti PROPERTY LINE <br /> C -" 1 CONTINUOUS - , (E)INTERCOM CROSS C <br /> RACEWAY/CABLING - # PROJECT IDENTIFICATION' <br /> CONNECT BLOCKS �I <br /> FOR FIRE ALARM - Jackson ES <br /> THROUGH THE �. <br /> JUNCTION BOX I Portable 6 <br /> "•" - /r JA��S�N E)FIRE ALARM <br /> FLAG NOTES FOR <br /> �- ANNUNCIATOR PANEL � PROVIDE AERIAL MESSENGER FOR LOW-VOLTAGE <br /> J I CABLING TO PORTABLE BUILDING.CLEARANCES <br /> VOLTAGE PATHWAY R �JN E VATI 'N ELEMENTARY SHALL BE MAINTAINED PER AHJ AND THE NEC. Everett Public <br /> (2)LOW OU7 G � O _12 n <br /> SCALE:NONE % / SCHOOL (E)INTERCOM SYSTEMLi <br /> FnnP -- PROVIDE DIRECT BURY WOOD POLE TO FACILITATE Schools <br /> (RAULAND TELECENTER) OVERHEAD ROUTING TO PORTABLES.PROVIDE POLE <br /> \ WITH HEIGHT AND MASTS TO ACCOMMODATE <br /> •7 (E)FIRE ALARM MINIMUM ELEVATION REQUIRED TO MAINTAIN AT <br /> CONTROL PANEL a 1MINIMUM NEC OVERHEAD CLEARANCE FROM GRADE <br /> PB - (1)1"C- IR ALARM— - AND ROOFS.PROVIDE ANCHORS AND GUY WIRE 3700 Federal Ave <br /> - — - - - - S (1)2"C- E ECOM/SECURITY ATTACHMENTS AT TOP OF WOOD POLE FOR <br /> SEPARATE PERMIT - - as ss'sz w- - - - - - - Everett WA 98201 <br /> TYPICAL OF GREY/ - INTERMEDIATE SUPPORT OF NEW AERIAL <br /> LIGHTENED LINE AERIAL CABLING,ROUTE CONDUCTORS. <br /> WEIGHT AREAS 2 (E)WOOD UTILITY ELECTRICAL PERMIT SET <br /> PROVIDE 2"C MAST WITH AERIAL MESSENGERS FOR 02/21/2024 <br /> � _ FIRE ALARM CABLING.CLEARANCES SHALL BE <br /> �, NE IRECT - - MAINTAINED PER AHJ AND THE NEC.PROVIDE This drawing is: <br /> URY UTI ITY POLE 12"X12"X6"PULL BOXES WITH(1)1"C TO PORTABLE 1.Copyright 2023 Dykeman,Inc. <br /> CRAWL SPACE AND(1)1"C TO CEILING SPACE.SEE 2.The Architect's Instrument of Professional Service. <br /> B <br /> PROPERTY LINE TYP 1 DETAIL 1 ON SHEET E7.02 FOR ADDITIONAL 3.For use on this project only.Obtain Architect's B <br /> E y INFORMATION. written permission for any other use or reproduction. <br /> _ <br /> —_-_--_- -- 1D <br /> 1 PROJECT <br /> E-P�_ <br /> PROVIDE 2"C MAST WITH AERIAL MESSENGERS FOR <br /> 1 LOW-VOLTAGE CABLING.CLEARANCES SHALL BE <br /> 1 1 (TYP) 1 I MAINTAINED PER AHJ AND THE NEC.PROVIDE 2023-056 <br /> E3.2 s I 12"X12"X6"PULL BOXES WITH(2)2"C TO PORTABLE <br /> CRAWL SPACE AND(2)2"C TO OF I I T J-1 •� T `-\ OW VOLTAGE CABLING, EE DETAIIL 3 ON SHEET <br /> CLOSURE R • <br /> E7.02 FOR ADDITIONAL INFORMATION. MARK DATE DESCRIPTION <br /> II " •LL 1 \- --I;I II s� PROVIDE(2)2"C FOR LOW VOLTAGE CABLING AND <br /> 3 (1)1'C FOR FIRE ALARM CABLING.CONDUIT SHALL <br /> (TYP I" =- ) ROUTE UNDER WELCOME RAMP AND TERMINATE IN <br /> 1 ¢ s a <br /> 1 '� PORTABLE CRAWL SPACE. <br /> __iJ <br /> � -� e PROVIDE(1)1"C FOR FIRE ALARM CABLING.CONDUIT <br /> EXISTING -J( FIRE ALARM II�� SHALL ROUTE UNDER WELCOME RAMP AND <br /> COVERED NA PANEL __ 3 TERMINATE IN PORTABLE CRAWL E7.2 SPACE. <br /> PLAY AREA �� UTILI OLESEE �� <br /> _- €T 1.1 SyE IDF-P6 7 PROVIDE(1)1'C FOR FIRE ALARM,(1)2"C FOR PROJECT <br /> / PORTABLE INTRUSION I INTERCOM AND(1)2"C FOR SECURITY CABLING. PRINCIPAL IN CHARNAGERGE:I BMI <br /> DETECTION-PANEL --- CONDUIT SHALL ROUTE UNDER WELCOME RAMP AND <br /> PROJECT ARCHITECT:I I — TERMINATE IN PORTABLE CRAWL SPACE. JPH,D. <br /> A <br /> JOB CAPTAIN: I DRAWING - <br /> o o*/ LOW VOLTAGE A <br /> O PRQVVPERTYLINE SYSTEMS SITE PLAN <br /> N <br /> 0 15' 30' sI <br /> LOW VOLTAGE SYSTEMS SITE PLAN Anmmi <br /> Jok <br /> E1.2 SCALE:1"=30'-0" Scale:1"=30'-0" <br /> NORTH <br /> 1 2 3 4 5 <br />