Laserfiche WebLink
2 3 1 4 1 5 <br /> FIRE ALARM NOTES SHEET NOTES <br /> 1. ROUTE NEW FIRE ALARM CONDUCTORS TO EXTEND EXISTING FIRE ALARM 1. SEE SHEET E1.2 FOR PULL BOX AND PORTABLE TO PORTABLE <br /> SYSTEM TO NEW PORTABLES.SEE SITE PLAN AND COORDINATE WITH FIRE PATHWAY REQUIREMENTS. DYKEMAN <br /> ALARM VENDOR FINAL SHOP DRAWINGS FOR ADDITIONAL INFORMATION. <br /> 2. SEE SHEET E1.2 FOR LOW-VOLTAGE SYSTEMS PANELS/HEADEND <br /> 2. EXISTING FIRE ALARM PANEL IS A NOTIFIER SYSTEM 5000 MODEL AND IS LOCATIONS. ARCHITECTURE + DESIGN <br /> LOCATED IN ADMIN AREA. <br /> 3. LOW-VOLTAGE CABLING ROUTED IN ACCESSIBLE CEILING SPACE <br /> D 3. FIRE ALARM DRAWINGS HAVE BEEN SUBMITTED TO AHJ FOR REVIEW AND AND IN CRAWL SPACE SHALL BE SUPPORTED VIA OPEN CABLING - D <br /> APPROVAL BASED ON DEVICE LAYOUTS SHOWN ON THESE DRAWINGS. METHODS. <br /> CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE FIRE ALARM SYSTEM <br /> INCLUDING ANY ADDITIONAL DEVICES REQUIRED BASED ON ONGOING REVIEW 4. RACEWAY AND CABLING SHALL BE CONCEALED IN WALLS,ABOVE <br /> AND PENDING APPROVAL.COORDINATE FIRE ALARM WORK WITH CONVERGINT ACCESSIBLE CEILING OR IN CRAWL SPACE UNLESS OTHERWISE <br /> FIRE AND SECURITY.POINT OF CONTACT IS:CURTIS NASATKA,425-902-2517, NOTED. <br /> CU RTIS.NASATKA@CON V ERG I NT.COM <br /> 4. PROVIDE NEW FIRE ALARM DEVICES AT LOCATIONS SHOWN.CONDUIT AND BACK FLAG NOTES H A R G I S <br /> BOXES FOR WALL MOUNTED DEVICES INDICATED ARE EXISTING. <br /> SEPARATE PERMIT � PROVIDE REMOTE MONITORING MODULE FOR HEAT DETECTORS <br /> TYPICAL OF GREY/ 5. PROVIDE PROGRAMMING AND COMPONENTS REQUIRED TO UPGRADE EXISTING ABOVE ACCESSIBLE CEILING.COORDINATE INSTALLATION WITH =01 third avenue,:ul.so0,,emle,w,99101 <br /> LIGHTENED LINE PANEL TO SERVE RELOCATED EXISTING AND ADDITIONAL NEW PORTABLES. FIRE ALARM SHOP DRAWINGS PRIOR TO ROUGH-IN. —all•2 AC8.400•n..a�.nn <br /> WEIGHT AREAS <br /> 8. OPEN CABLING ABOVE CEILINGS IS ACCEPTABLE. LOCATE TOP OF NAC PANEL FLUSH WITH CEILING SUCH THAT FA <br /> CABLING AND HOMERUN RACEWAY CAN REMAIN CONCEALED IN <br /> ACCESSIBLE CEILING SPACE. • <br /> PROVIDE RECESSED ROUGH-IN FOR NEW DEVICE INDICATED TO pgr,� <br /> ACCOMMODATE INSTALLATION OF STOPPER II COVER PER <br /> SPECS.PROVIDE CONCEALED ROUTING OF FA CABLING FROM <br /> DEVICE TO ACCESSIBLE CEILING SPACE. <br /> o o <br /> oil <br /> LJ sltigty <br /> c o o LJ C <br /> PROJECT IDENTIFICATION: <br /> H H H H 0 3 0 <br /> Jackson ES <br /> Pz P3 Portable 6 <br /> PROPOSFD PROPOSED <br /> BLE <br /> PORTABLE <br /> 5 5 � J <br /> H H �n H � H n H FOR <br /> °0 Everett Public <br /> 0 H 0 H 0 0 0 0 0 Schools <br /> F <br /> F F F F S F AT <br /> ,' 3 3700 Federal Ave <br /> Everett WA 98201 <br /> wP - WPMF ELECTRICAL PERMIT SET <br /> s F F F 4 02/21/2024 <br /> F F <br /> L as This drawing is: <br /> 1.Copyright 2023 Dykeman,Inc. <br /> F F � � � � 2.The Architect's Instrument of Professional Service. <br /> g 3.For use on this project only.Obtain Architect's g <br /> P4 P5 written permission for any other use or reproduction. <br /> PROPOSED PROPOSED Pg p7 <br /> PORTABLE PORTABLE PROPOSED PROPOSEDPROJECT <br /> 1 1 <br /> (H) ""'TTn O (­—D PORTABLE PORTARIF <br /> D a 0 0 L01 o L01 0 LEI O LEI LEI D O D 0 2023-056 <br /> `(E)FA REMOTE `(E)FA REMOTE • <br /> INDICATOR INDICATOR a <br /> z MARK DATE DESCRIPTION <br /> PROJECT <br /> PRINCIPAL IN CHARGE: BMI <br /> PROJECT MANAGER: I JPH,DB <br /> PROJECT ARCHITECT:I- <br /> JOB CAPTAIN: I DRAWING - <br /> A A <br /> PORTABLE LIGHTING <br /> AND FIRE ALARM <br /> FLOOR PLANS <br /> 1 PORTABLE LIGHTING AND FIRE ALARM FLOOR PLANS 0Anmmi 4' B' ,I <br /> ea.t SCALE:1/8"=V-0" <br /> Scale:1/8"=1'-0" <br /> NORTH <br /> 1 2 3 4 5 <br />