My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE PORTABLE 6 JACKSON ELEMENTARY 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE PORTABLE 6 JACKSON ELEMENTARY 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 2:30:29 PM
Creation date
5/1/2025 3:02:07 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Unit
PORTABLE 6
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br /> �DWARDS Model 6.5 amp Booster 10 amp Booster <br /> AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz <br /> 390 watts 580 watts <br /> LIFE SAFETY&INCIDENT MANAGEMENT Notification Appliance 3.OA max.per circuit @ 24Vdc 3.OA max.per circuit @ 24Vdc <br /> Contact us Circuit Ratings nominal 6.5A max total all NACs nominal 1 OA max total all NACs <br /> Phone: 800-655-4497(Option 4) Trouble Relay 2 Amps @ 30Vdc <br /> Email: edwards.fire@carrier.com Auxiliary Outputs Four configurable outputs replace NACs 1,2,3 or 4. as auxiliary <br /> Website: edwardsfiresafety.com outputs and 200 mA dedicated auxiliary.(See note 1.) <br /> 8985 Town Center Pkwy Input Current 3mA @ 12Vdc,6mA @ 24Vdc <br /> Bradenton,FL 34202 (from an existing NAC) <br /> Booster Internal 70mA+35 mA for each circuit set to AUX <br /> ©2021 Carrier Supervisory Current <br /> All rights reserved. <br /> Booster Internal Alarm 270mA <br /> Current <br /> Signature Mounting Accomodates three two-gang modules. <br /> Space <br /> Maximum Battery Size 10 Amp Hours(2 of 12V1 OA)in cabinet up to 24 Amp hours with <br /> external battery cabinet for fire applications. <br /> Terminal Wire Gauge 18-12 AWG <br /> Relative Humidity 0 to 93%non condensing @ 32°C <br /> Temperature Rating 32°to 120°F(O°to 49°C) <br /> NAC Wiring Styles Class A or Class B <br /> Output Signal Rates Continuous,3-3-3 temporal, <br /> or follow installed panel's NAC. <br /> Ground Fault Detection Enable or Disable via jumper <br /> Agency Listings UL,ULC,CSFM <br /> 1. Maximum of 8 Amps can be used for auxiliary output. <br /> Ordering Information <br /> Catalog Description Shipping <br /> Number Wt.lb(kg) <br /> �► BPS6A 6.5 Amp Booster Power Supply 13(5.9) <br /> BPS6AC 6.5 Amp Booster Power Supply(ULC) 13(5.9) <br /> BPS6A/230 6.5 Amp Booster Power Supply(220V) 13(5.9) <br /> BPS1 OA 10 Amp Booster Power Supply 13(5.9) <br /> BPS1 OAC 10 Amp Booster Power Supply(ULC) 13(5.9) <br /> BPS1 OA/230 10 Amp Booster Power Supply(220V) 13(5.9) <br /> Related Equipment <br /> 1. Requires installation of sepa- 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) <br /> rate battery cabinet. 12V10A 10 Amp Hour Battery,two required 9.5(4.3) <br /> 2. For earthquake anchorage, 3-TAMP Tamper switch <br /> including detailed mounting <br /> weights and center of gravity BPS-CVR Electronics Protective Cover <br /> detail,refer to Seismic Applica- BC-1 EQ Seismic Kit for BC-1. Order BC-1 separately.See note 2 <br /> tion Guide 3101676. Approval BPSEQ Seismic kit for BPS6A or BPS10 Booster Power Supplies.See <br /> of panel anchorage to site note 2 <br /> structure may require local BC-1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) <br /> AHJ,structural or civil engineer <br /> review. BC-2 Battery Cabinet(up to 2-17 Amp Hour Batteries) 19(8.6) <br /> 12V17A 18 Amp Hour Battery,two required(see note 1) 13(5.9) <br /> 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) <br /> a <br /> w <br /> Page 4 of 4 DATA SHEET E85005-0125 N <br /> Not to be used for installation purposes. Issue 1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.